3
Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18
Installation Standard Work Checklist
Customer:
Lot/Address:
Model (circle one): QFI30FB-IFT, QFI35FB-IFT
Date Installed:
Location of Fireplace:
Installer:
Dealer/Distributor Phone #
Serial #:
Comments:
Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective
action needed _____________________________________________________________________________________
_________________________________________________________________________________________________
_________________________________________________________________________________________________
Comments Communicated to party responsible ____________________ by ______________________on ___________
(Builder / Gen. Contractor/) (Installer) (Date)
Appliance Install
YES
IF NO, WHY?
Verify fireplace is clean and remove/block open damper/modify
damper for vent pipe clearance (Pg. 12) . __________________________
Appliance is leveled and secured (Pg. 15). __________________________
Venting/Chimney Section 7 (Pg. 13-17)
Exhaust stainless steel flex is properly formed and routed through
existing fireplace damper. ___________________________
Vent intake and exhaust liners are properly installed to the correct collars,
sealed and secured to top plate and to the termination cap.
___________________________
Termination cap installed, secured and sealed to top plate.
___________________________
Electrical Section 8 (Pg. 18-20)
Unswitched power (110-120 VAC) provided to the appliance.
___________________________
Switch wires properly installed.
___________________________
Gas Section 9 (Pg. 21-22)
Proper appliance for fuel type.
___________________________
Was a conversion performed?
___________________________
Leak check performed and inlet pressure verified. ____________________________
Verified proper air shutter setting for installation type.
___________________________
Finishing Section 10 (Pg. 23)
Combustible materials not
installed in non-combustible areas.
___________________________
Verified all clearances meet installation manual requirements.
___________________________
Mantels and wall projections comply with installation manual requirements.
___________________________
Appliance Setup Section 11 (Pg. 24-33)
All packaging and protective materials removed (inside & outside of appliance).
___________________________
Refractories, logs, media and embers installed correctly.
___________________________
Glass assembly installed and secured.
___________________________
Accessories installed properly.
___________________________
Surround or decorative front properly installed.
___________________________
Manual bag and all of its contents are removed from inside/under
the appliance and given to party responsible for use and operation.
___________________________
Fireplace warning plate is attached to the existing woodburning fireplace. ___________________________
Remote control is programmed, functions verified using remote control
instructions. ___________________________
Started appliance and verified no gas leaks exist.
___________________________
2555-982 5/18
= Contains updated information.
Hearth & Home Technologies recommends the following:
• Photographing the installation and copying this checklist for your file.
• That this checklist remain visible at all times on the appliance until the installation is complete.
This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this
installation manual.
WARNING! Risk of Fire or Explosion!
Failure to install appliance according to these instructions can
lead to a fire or explosion.
ATTENTION INSTALLER:
Follow this Standard Work Checklist