4
7082-131J
August 3, 2015
MT VERNON E2 INSERT
Install Guide
2
Getting Started
Marginal Location:
• Below peak
Location NOT recommended:
• Not the highest point of the roof
• Wind loading possible
Multi-level Roofs
Windward
Leeward
Recommended:
Outside Air Intake
on windward side
NOT recommended:
Outside Air Intake
on leeward side
Recommended Location:
• Above peak
Recommended:
• Insulated exterior chase
in cooler climates
Recommended Location:
• Above peak
• Inside heated space
Location NOT recommended:
• Too close to tree
• Below adjacent structure
• Lower roof line
• Avoid outside wall
Marginal Location:
• Wind loading possible
Figure 4.1
A. Design, Installation & Location Considerations
1. Appliance Location
NOTICE: Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult insurance carrier, local building inspector, fi re
offi cials or authorities having jurisdiction over restrictions,
installation inspection and permits.
It is a good idea to plan your installation on paper, using exact
measurements for clearances and fl oor protection, before
actually beginning the installation. Location of the appliance
and chimney will affect performance.
Consideration must be given to:
• Safety, convenience, traffi c fl ow
• Placement of the chimney and chimney connector and to
minimize the use of chimney offsets.
• Place the appliance where there will be a clear passage
for a Listed chimney through the ceiling and roof (vertical)
or through exterior wall (horizontal).
• Installing the required outside air kit will affect the location
of the vent termination.
When locating vent and venting termination, the ideal loca-
tion is to vent above roof line when possible. This minimizes
the affects of wind loading.
Since pellet exhaust can contain ash, soot or sparks, you
must consider the location of:
• Windows
• Air
Intakes
• Air
Conditioner
• Overhang,
soffi ts, porch roofs, adjacent walls
• Landscaping,
vegetation
• Horizontal or vertical vent termination
2. Floor Support
The supporting fl oor under the appliance must be able to
handle the weight of the appliance, fuel load and the weight
of the chimney.
Ensure that your fl oor will support these weights prior to
installation. Add suffi cient additional support to meet this
weight requirement prior to installation. The weight of the
appliance is 510 lbs. with a full load of fuel the max weight
is 557 lbs.
WARNING
Risk of Fire!
Damaged parts could impair safe operation.
Do NOT install damaged, incomplete or substitute com-
ponents.
Содержание MTVI-E2-MBK
Страница 26: ...26 7082 131J August 3 2015 MT VERNON E2 INSERT ...
Страница 27: ...August 3 2015 7082 131J 27 MT VERNON E2 INSERT ...