MT. VERNON E2 INSERT

-C

Following correction of any Alarm, turn the dial control to the OFF position, wait 10 seconds and turn back to 

desired setting OR unplug the appliance, wait 10 seconds then restore power.

Alarm

(LED Flashing RED)

Possible Cause

Corrective Action

1 Red Flash: Empty Hopper Alarm

Hopper empty

Fill the hopper

Auger jam

Inspect the feed tube for jams

Vacuum switch not closing

Make sure firebox door is shut, 

vacuum hose is connected to switch 

and drop tube, wire connectors are 

connected to vacuum switch, control 

board, hopper switch, and safety 

snap disc. 

Hopper lid open

Close the hopper lid

Exhaust probe does not sense tem-

perature

Secure the exhaust probe keeping 

its wire away from hot surfaces and 

clean the exhaust plenum

Snap disc tripped (#3)

Reset snap disc

Exhaust probe not attached to 

exhaust blower properly

Secure exhaust probe to exhaust 

blower housing – keeping its wire 

away from hot surfaces

Exhaust path is dirty

Clean appliance including the fire pot, 

exhaust path, and venting system

2 Red Flashes: Exhaust Probe Fail

Not connected to the control board

Connect terminal end to control board

Failed component

Replace exhaust probe – securing it 

to exhaust blower housing – keeping 

wire away from hot surfaces

4 Red Flashes: Missed Ignition

Hopper empty

Fill the hopper

Feed motor doesn’t turn

Inspect feed motor circuit (hopper lid 

must be closed, vacuum switch must 

be closed, snap disc closed, and feed 

motor must be plugged in)

Clear jam in feed tube

Dirty appliance

Clean appliance including the fire pot, 

exhaust path, and venting system

Igniter has no power or is defective

Check igniter lead connections or 

replace igniter

Exhaust probe not properly installed

Secure exhaust probe to exhaust 

blower housing – keeping its wire 

away from hot surfaces

Igniter chamber plugged with debris

Clean igniter chamber

6 Red Flashes: Exhaust Blower 

Alarm

Wire from exhaust blower or encoder 

is disconnected or shorted

Make sure wire is not damaged / 

melted and ends are fully connected 

to the encoder and control board.

Defective exhaust blower

Replace exhaust blower

Defective encoder (on end of 

exhaust blower)

Replace exhaust blower

8 Red Flashes: Exhaust Over-Temp

Feed Motor Locked On

Repair wire(s) and replace control 

board 

Non-approved fuel used

Only use wood pellet fuel.  Do not 

enhance its performance with any 

other combustible substance.

Convection blower dirty

Clean impellers

Содержание MTVI-E2-MBK-C

Страница 1: ...QuadraFire com 00Pour obtenir une traduction fran aise de ce manuel s il vous pla t contacter votre revendeur ou visitez www QuadraFire com CAUTION Check building codes prior to installation Installat...

Страница 2: ...Room Heating Pellet Burning Type UM 84 HUD POUR USAGE AVEC LES BOULETTES DE BOIS N utiliser aucun autre genre de combustible Puissance de Rendement 55 00 Btu s hr Puissance lectrique 115 VAC 60 Hz D b...

Страница 3: ...8 A Fire Safety 8 B Non Combustible Materials 8 C Combustible Materials 8 D Fuel Material and Fuel Storage 8 E Before Your First Fire 8 F Filling the Hopper 9 G User Dial Control 9 H Normal Startup S...

Страница 4: ...home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occ...

Страница 5: ...y does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw...

Страница 6: ...eeded for rst re or starting re on empty hopper Note The prime function is only required during initial set up of the unit or after the unit has alarmed out due to an empty hopper Priming while under...

Страница 7: ...d the warranty will be voided by the following actions B BTU Efficiency Specifications The Quadra Fire Mt Vernon E2 Pellet Insert Appliance meets the U S ENVIRONMENTAL PROTECTIONAGENCY Certified to co...

Страница 8: ...Depending on the source material it may have a high or low ash content Higher Ash Content Material Hardwoods with a high mineral content Fuel that contains bark Standard grade pellets or high ash pell...

Страница 9: ...tion happens the smoke should quickly disap pear During this stage as well as any part during the burn process the front door should not be opened This startup cycle continues until the appliance sens...

Страница 10: ...tial operation Curing of high temperature paint Open windows for air circulation Odors may be irritating to sensitive individuals CAUTION WARNING HOT SURFACES Glass and other surfaces are hot during o...

Страница 11: ...he exhaust temperature has cooled Green 1X Stage 1 Low heat BTU Range 14 620 19 694 Average 19 054 Green 2X Stage 2 Med Low heat BTU Range 22 102 23 506 Average 22 735 Green 3X Stage 3 Med heat BTU Ra...

Страница 12: ...educed by means ap proved by the regulatory authority having jurisdiction Mantel Avoid placing candles and other heat sensitive ob jects on mantel or hearth Heat may damage these objects P Trim Adjust...

Страница 13: ...the day To cancel the temporary setting at any time press RUN SCHEDULE Program Schedule Override permanent Press HOLD to permanently adjust the temperature This will override the temperature settings...

Страница 14: ...n burn season see troubleshooting section Is there a place to lubricate the blowers to quiet them down No The most often cause of noisy blowers is from the impellers becoming dirty over time See maint...

Страница 15: ...a dealer We recommend annual service by a qualified dealer A Proper Shutdown Procedure Turn dial control to OFF let appliance completely cool and exhaust blower must be off Now you can unplug appli an...

Страница 16: ...s on the 2 side latches Clinkers filling the ash pan will have to be cleaned out more often than ash Ash Disposal Ashes should be placed in a steel container with a tight fitting lid The container of...

Страница 17: ...ove the majority of the ash Be sure to vacuum the back of the baffle also Inspect the drop tube and remove any residue build up in the drop tube Figure 17 3 c Assemble the crevice tool from the micro...

Страница 18: ...e the appliance is allowed to cool b Open the front cast door and cycle the ash removal handle these should be inspected for functionality c Inspect for any degradation or deformation As the springs h...

Страница 19: ...e glass and firebox should be inspected periodically to make sure there is a good seal If the gasket is frayed or damaged replace with a new one 9 Cleaning Exhaust System Requires No Lubrication Frequ...

Страница 20: ...nformation on how to handle a chimney fire In the event of a soot or creosote fire close the firebox door exit the building immediately and contact the proper fire authorities DO NOT under any circums...

Страница 21: ...21 2 5 Rock the top of the blower slightly and lift up The blower will pass out the left side of the appliance Note You may need to loosen the surround to move it out of the way 6 Install replacement...

Страница 22: ...ch wires for integrity Safety snap disc is tripped 3 Check to make sure convection blower wires are connected and reset snap disc located on RH side of appliance Clean inspect convection blower and co...

Страница 23: ...er Exhaust probe not sensing correct temperature Secure the exhaust probe to exhaust blower housing keeping its wire away from hot surfaces Control board is defective Replace control board Convection...

Страница 24: ...l spilling over the fire pot and or excessive flame Dirty Appliance Clean appliance including the fire pot exhaust path and venting system Feed Motor locked on Follow corrective action for feed motor...

Страница 25: ...Connect terminal end to control board Failed component Replace exhaust probe securing it to exhaust blower housing keeping wire away from hot surfaces 4 Red Flashes Missed Ignition Hopper empty Fill t...

Страница 26: ...vection Blower The convection blower is mounted at the bottom left of the appliance The convection blower pushes heated air through the heat exchange system into the room 4 Feed System The feed system...

Страница 27: ...TVI E2 C Beginning Manufacturing Date July 2017 Ending Manufacturing Date Active Pellet Insert MTVI E2 CSB C MTVI E2 MBK C MTVI E2 PMH C Part number list on following pages 11 17 39 38 37 36 35 34 33...

Страница 28: ...BK Porcelain Mahogany 7036 101PMH Sienna Bronze 7036 101CSB 4 Catch Clip 7036 146 5 Elbow Catch 7000 393 6 Bracket Catch 7036 145 7 Backer Side Window 414 0280 8 Side Matte Black 7036 103MBK Porcelain...

Страница 29: ...Y 19 3 Hinge Female SRV450 2910 19 4 Door Latch Assembly 413 5200 Gasket Channel 3 Mm X 32 Field Cut to Size 10 Ft 7000 377 10 Y 20 Ash Pan Door 7034 133 21 Ash Pan Assembly SRV7034 069 Twin Ball cat...

Страница 30: ...SRV7080 106 Y Gasket Blower Combustion Between Housing Stove SRV7080 117 Y Gasket Motor Blower Combustion Between Housing Motor SRV7080 107 Y 31 Snap Disc L250 Manual Reset 3 SRV230 1290 Y Gasket Exh...

Страница 31: ...60 AE B Y Outside Air Kit OAK 3 Top Vent Adapter TPVNT 4 Surround Std Panel For Cast Trim SP MTVS CST Component Pack 7036 041 Surround Std Panel w Gold Trim SP MTVS GD Component Pack 7036 042 Trim Pa...

Страница 32: ...e purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dea...

Отзывы: