background image

 2 

 

 

 

 

                        7082-151C 

 

 

 

       November 28, 2017

MT. VERNON E2 INSERT

-C

A. Sample of Serial Number / Safety Label

LOCATION:  Behind right cast side panel

Serial No.

Model 

Name

Test Lab & 

Report No.

Mfg. Date

S A

M P

L E

Mt Vernon E2 Pellet Insert

R

SERIAL NO. / NUMÉRO DU

007059

Listed Solid Fuel Room Heater/Pellet Type.  Also suitable for Mobile Home Installation.  This appliance has 

been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 

814-23-909.

Appareil de chauffage de combustible solide/de type de boulettes.  Accepté dans l'installation dans les 

maisons mobiles.  Cet appareil a été testé et enregistré pour l'usage dans les Maisons Mobiles en accord 

avec OAR 814-23-9000 jusqu'à 814-23-909.

PREVENT HOUSE FIRES / 

PRÉVENTION DES FEUX DE MAISON

Install and use only in accordance with manufacturer's installation and operating instructions.  Contact local 

building or fire officials about restrictions and inspection in your area.

WARNING - FOR MOBILE HOMES:  Do not install appliance in a sleeping room.  An outside combustion air 

inlet must be provided.  The structural integrity of the mobile home floor, ceiling and walls must be maintained.  

Refer to manufacturer's instructions and local codes for precautions required for passing chimney through a 

combustible wall or ceiling.  Inspect and clean vent system frequently in accordance with manufacturer's 

instructions.  DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING ANOTHER APPLIANCE.  Use a 3" 

or 4" diameter type "L" or "PL" venting system.

Installez et utilisez en accord avec les instructions d'installation et d'opération du fabricant. Contactez le 

bureau de la construction ou le bureau des incendies au sujet des restrictions et des inspections d'installation 

dans votre voisinage. Ne pas obstruez l'espace en dessous de l'appareil.

AVIS - Pour Les Maisons Mobiles:  Ne pas installer dans une chambre à coucher. Un tuyau extérieur de 

combustion d'air doit être installé et ne doit pas être obstrué lorsque l'appareil est en usage. La structure 

intégrale du plancher, du plafond et des murs de la maison mobile doit être maintenue intacte.  Référez vous 

aux instructions du fabricant et des codes locaux pour les précautions requises pour passer une cheminée à 

travers un mur ou un plafond combustibles, et les compensations maximums.  Inspectez et nettoyez la 

cheminée fréquemment. Ne pas connecter cet appareil à une cheminée servant un autre appareil.  Utilisez 

systèm de ventilation "L" ou "PL" diamètre 76mm ou 102mm

Conforms to ASTM Std E1509-12. Certified to ULC S628-93. Room Heating Pellet BurningType,  (UM) 

84-HUD FOR USE ONLY WITH PELLETIZED WOOD  FUEL. Do not use any other type of fuel.  
Input Rating: 55,000 Btu's/hr.  Electrical Rating:115 VAC, 60 Hz, Start 2.9 Amps, Run 2.45 Amps.  Route 

power cord away from unit.  Do not route cord under or in front of appliance.  Do not obstruct the space 

beneath the heater.

DANGER

:  Risk of electrical shock.  Disconnect power supply before servicing.  Replace glass only with 5mm 

ceramic.  To start, turn dial control to desired setting and set thermostat above room temperature, the stove 

will light automatically.  To shutdown, turn dial control to OFF or set thermostat below room temperature.  For 

further instruction refer to owner's manual.  Keep viewing doors tightly closed during operation.  Keep viewing 

and ash removal doors tightly closed during operation.
Conforme à la norme ASTM E1509-12 Std. Certifié à la norme ULC S628-93. Room Heating Pellet Burning 

Type, (UM) 84-HUD POUR USAGE AVEC LES BOULETTES DE BOIS.  N’utiliser aucun autre genre de 

combustible.  
Puissance de Rendement: 55,00 Btu's/hr.  

Puissance Électrique: 115 VAC, 60 Hz,

 Début 2.9 Amps, Courir 

2.45 Amps,  Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en 

dessous 

de l'appareil.  

Ne pas bloquer l’espace au dessous de l’appareil

.  

DANGER:

 Il y a risque de décharge électrique.  Déconnectez le fil électrique de la prise de contact avant le 

service.  Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur.  

Pour commencer, tournez la molette de réglage à la température désirée et réglez le thermostat au-dessus de 

la température ambiante, le poêle s'allumera automatiquement. Pour éteindre, tournez la molette de réglage 

sur OFF ou réglez le thermostat dessous de la température ambiante.  Pour des instructions supplémentaires, 

référez vous au manuel du propriétaire.  Gardez la porte d'ouverture et la porte des cendres fermées 

hermétiquement durant l'opération.

7082-133B

HOT WHILE IN OPERATION DO NOT TOUCH, KEEP 

CHILDREN, CLOTHING AND FURNITURE AWAY. 

CONTACT MAY CAUSE SKIN BURNS.  SEE NAMEPLATE AND INSTRUCTIONS.  

CAUTION:

CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. 

GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE 

L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES 

BRÛLURES À LA PEAU.  VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.  

ATTENTION:

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS / ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES
AS A BUILT-IN UNIT / COMME APPAREIL INSÉRÉ

A  Top of Hopper / Haut de la trémie 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

3 in [76mm]

B  Side of Outside Skin / Côté de Enveloppe extérieure 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

2 in [51mm]

C   Vent Pipe to Combustible / Des Conduits de combustible 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

3 in [76mm]

D  Cast Side to Side Wall / Moulage Side à Wall Side 

Top/Rear Vent / Des Conduits Du Haut/Arrières 

6 in [152mm]

D

B

B

C

A

MASONRY OR ZERO CLEARANCE / DÉGAGEMENT DE LA MAÇONNERIE OU DÉGAGEMENT ZÉRO*

SIDE W

ALL

 / 

MUR LA

TÉRAL

MANTEL / MANTEAU

C

A

B

D

E

A Cast Side to Side Wall / Moulage Side à Wall Side 

6 in [152 mm]

B Insert top to face trim / Insérez le dessus de la garniture de façade 

0 in [0 mm]

C Insert side to face trim / Insérez le côté de la garniture de façade 

0 in [0 mm]

D Hearth extension from door opening / Prolongement d’âtre depuis l’ouverture de la porte devant 

6 in [152 mm]

E Hearth extension from side of door opening / Prolongement d’âtre depuis le côté de l’ouverture de la porte 

6 in [152 mm]

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2015 particulate emission standards at 0.5 g/hr EPA Method 28 and 

5G. Not approved for sale after May 15, 2020

This wood heater needs periodic inspection and repair for proper operation. Consult the 

owner’s manual for further information. It is against federal regulations to operate this wood 

heater in a manner inconsistent with the operating instructions in the owner’s manual.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

Made in U.S.A. 

of US and imported parts.

Fabriqué aux États-Unis-d’Amérique par des pièces d’origine américaine et pièces importées.

2015

2016

2017

JAN

FEB

MAR

APR

MAY

JUN

JUL

AUG

SEP

OCT

NOV

DEC

1445 North Highway, Colville, WA  99114

www.quadrafire.com

Manufactured by:Fabriqué par

Owners Manual

Install Manual

O-T  L

Tested and 

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

Report:

 061-S-84-2 

NOTE:  Clearances may only be reduced by means 

approved by the regulatory authority having jurisdiction

and Welcome to the Quadra-Fire Family

!

Содержание MTVI-E2-MBK-C

Страница 1: ...QuadraFire com 00Pour obtenir une traduction fran aise de ce manuel s il vous pla t contacter votre revendeur ou visitez www QuadraFire com CAUTION Check building codes prior to installation Installat...

Страница 2: ...Room Heating Pellet Burning Type UM 84 HUD POUR USAGE AVEC LES BOULETTES DE BOIS N utiliser aucun autre genre de combustible Puissance de Rendement 55 00 Btu s hr Puissance lectrique 115 VAC 60 Hz D b...

Страница 3: ...8 A Fire Safety 8 B Non Combustible Materials 8 C Combustible Materials 8 D Fuel Material and Fuel Storage 8 E Before Your First Fire 8 F Filling the Hopper 9 G User Dial Control 9 H Normal Startup S...

Страница 4: ...home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occ...

Страница 5: ...y does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw...

Страница 6: ...eeded for rst re or starting re on empty hopper Note The prime function is only required during initial set up of the unit or after the unit has alarmed out due to an empty hopper Priming while under...

Страница 7: ...d the warranty will be voided by the following actions B BTU Efficiency Specifications The Quadra Fire Mt Vernon E2 Pellet Insert Appliance meets the U S ENVIRONMENTAL PROTECTIONAGENCY Certified to co...

Страница 8: ...Depending on the source material it may have a high or low ash content Higher Ash Content Material Hardwoods with a high mineral content Fuel that contains bark Standard grade pellets or high ash pell...

Страница 9: ...tion happens the smoke should quickly disap pear During this stage as well as any part during the burn process the front door should not be opened This startup cycle continues until the appliance sens...

Страница 10: ...tial operation Curing of high temperature paint Open windows for air circulation Odors may be irritating to sensitive individuals CAUTION WARNING HOT SURFACES Glass and other surfaces are hot during o...

Страница 11: ...he exhaust temperature has cooled Green 1X Stage 1 Low heat BTU Range 14 620 19 694 Average 19 054 Green 2X Stage 2 Med Low heat BTU Range 22 102 23 506 Average 22 735 Green 3X Stage 3 Med heat BTU Ra...

Страница 12: ...educed by means ap proved by the regulatory authority having jurisdiction Mantel Avoid placing candles and other heat sensitive ob jects on mantel or hearth Heat may damage these objects P Trim Adjust...

Страница 13: ...the day To cancel the temporary setting at any time press RUN SCHEDULE Program Schedule Override permanent Press HOLD to permanently adjust the temperature This will override the temperature settings...

Страница 14: ...n burn season see troubleshooting section Is there a place to lubricate the blowers to quiet them down No The most often cause of noisy blowers is from the impellers becoming dirty over time See maint...

Страница 15: ...a dealer We recommend annual service by a qualified dealer A Proper Shutdown Procedure Turn dial control to OFF let appliance completely cool and exhaust blower must be off Now you can unplug appli an...

Страница 16: ...s on the 2 side latches Clinkers filling the ash pan will have to be cleaned out more often than ash Ash Disposal Ashes should be placed in a steel container with a tight fitting lid The container of...

Страница 17: ...ove the majority of the ash Be sure to vacuum the back of the baffle also Inspect the drop tube and remove any residue build up in the drop tube Figure 17 3 c Assemble the crevice tool from the micro...

Страница 18: ...e the appliance is allowed to cool b Open the front cast door and cycle the ash removal handle these should be inspected for functionality c Inspect for any degradation or deformation As the springs h...

Страница 19: ...e glass and firebox should be inspected periodically to make sure there is a good seal If the gasket is frayed or damaged replace with a new one 9 Cleaning Exhaust System Requires No Lubrication Frequ...

Страница 20: ...nformation on how to handle a chimney fire In the event of a soot or creosote fire close the firebox door exit the building immediately and contact the proper fire authorities DO NOT under any circums...

Страница 21: ...21 2 5 Rock the top of the blower slightly and lift up The blower will pass out the left side of the appliance Note You may need to loosen the surround to move it out of the way 6 Install replacement...

Страница 22: ...ch wires for integrity Safety snap disc is tripped 3 Check to make sure convection blower wires are connected and reset snap disc located on RH side of appliance Clean inspect convection blower and co...

Страница 23: ...er Exhaust probe not sensing correct temperature Secure the exhaust probe to exhaust blower housing keeping its wire away from hot surfaces Control board is defective Replace control board Convection...

Страница 24: ...l spilling over the fire pot and or excessive flame Dirty Appliance Clean appliance including the fire pot exhaust path and venting system Feed Motor locked on Follow corrective action for feed motor...

Страница 25: ...Connect terminal end to control board Failed component Replace exhaust probe securing it to exhaust blower housing keeping wire away from hot surfaces 4 Red Flashes Missed Ignition Hopper empty Fill t...

Страница 26: ...vection Blower The convection blower is mounted at the bottom left of the appliance The convection blower pushes heated air through the heat exchange system into the room 4 Feed System The feed system...

Страница 27: ...TVI E2 C Beginning Manufacturing Date July 2017 Ending Manufacturing Date Active Pellet Insert MTVI E2 CSB C MTVI E2 MBK C MTVI E2 PMH C Part number list on following pages 11 17 39 38 37 36 35 34 33...

Страница 28: ...BK Porcelain Mahogany 7036 101PMH Sienna Bronze 7036 101CSB 4 Catch Clip 7036 146 5 Elbow Catch 7000 393 6 Bracket Catch 7036 145 7 Backer Side Window 414 0280 8 Side Matte Black 7036 103MBK Porcelain...

Страница 29: ...Y 19 3 Hinge Female SRV450 2910 19 4 Door Latch Assembly 413 5200 Gasket Channel 3 Mm X 32 Field Cut to Size 10 Ft 7000 377 10 Y 20 Ash Pan Door 7034 133 21 Ash Pan Assembly SRV7034 069 Twin Ball cat...

Страница 30: ...SRV7080 106 Y Gasket Blower Combustion Between Housing Stove SRV7080 117 Y Gasket Motor Blower Combustion Between Housing Motor SRV7080 107 Y 31 Snap Disc L250 Manual Reset 3 SRV230 1290 Y Gasket Exh...

Страница 31: ...60 AE B Y Outside Air Kit OAK 3 Top Vent Adapter TPVNT 4 Surround Std Panel For Cast Trim SP MTVS CST Component Pack 7036 041 Surround Std Panel w Gold Trim SP MTVS GD Component Pack 7036 042 Trim Pa...

Страница 32: ...e purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dea...