 8 

 

 

 

 

                        7034-277B 

 

 

 

                 May 2, 2014

MT. VERNON AE

Straight Back Against  Wall

Inches

Millimeters

A

Back Wall to Appliance

2

51

B

Side Wall to Appliance

6

152

Corner Installation

Inches

Millimeters

C

Walls to Appliance

2

51

Vertical Installation

Inches

Millimeters

D

Back Wall to Flue Pipe

3

76

E

Side Wall to Appliance

6

152

F

Back Wall to Appliance

8

203

Installations with:

3 to 3 inch Top Vent Adapter and

3 to 6 inch Offset Adapter Kit

Corner Installation 

Inches

Millimeters

G

Side Wall to Flue Pipe

3

76

Alcove Installation

Inches

Millimeters

Minimum Alcove Height

43

1092

Minimum Alcove Side Wall

6

152

Minimum Alcove Width

40

1016

Maximum Alcove Depth

36

914

 

*L Exception for Horizontal Installations:
USA INSTALLATIONS

: A non-combustible  floor  protec-

tion is recommended extending beneath the flue pipe when 

installed  with  horizontal  venting  or  under  the  Top  Vent 

Adapter with vertical installation.

CANADA INSTALLATIONS

:  A non-combustible floor pro-

tection extending beneath the flue pipe is 

required

 with hor-

izontal venting or under the Top Vent Adapter with vertical 

installation.

Must extend 2 inches (51mm) beyond each 

side of pipe  (shaded area) 

NOTE:

  Illustrations reflect typical installations and are FOR 

DESIGN PURPOSES ONLY.

 I

llustrations/diagrams are not drawn to scale.

  Actual installation may vary due to individual design 

preference.

G

G

L* 

Use a non-combustible  floor  protector,  extending  beneath 

appliance and to the front, sides and rear as indicated.  Mea-

sure front distance “M” from the surface of the glass door.

Hearth Pad Requirements

Inches

Millimeters

K

Sides

2

51

L*

Back

2

51

M

Front

6

152

B. Clearances to Combustibles (UL and ULC)

C. Hearth Pad Requirements (UL and ULC)

Fire Risk.
Comply with all minimum clearances to combustibles 

as specified.
Failure to comply may cause house fire.

WARNING

Содержание MTVERNON-AE-CSB

Страница 1: ...rmation in these instruc tions is not followed exactly a fire may result causing property damage personal injury or death Do not store or use gasoline or other flam mable vapors and liquids in the vic...

Страница 2: ...Alcove 13 B Through The Wall 14 C Vertical into Existing Class A Chimney 15 D Through The Wall Vertical Exterior 15 E Vertical Interior Typical Installation 15 F Masonry 16 G Alternate Masonry 16 6 Ap...

Страница 3: ...Installation other than as instructed by Hearth Home Technologies Installation and or use of any component part not approved by Hearth Home Technologies Operating appliance without fully assembling a...

Страница 4: ...given to Safety convenience traffic flow Placement of the chimney and chimney connector and to minimize the use of chimney offsets Place the appliance where there will be a clear passage for a Listed...

Страница 5: ...is an integral part of the appliance No other wall control or thermostat can be substituted D Inspect Appliance and Components Open the appliance and remove all the parts and articles packed inside th...

Страница 6: ...roper clearance Chimney meets the minimum height requirements Roof flashing installed and sealed Terminations installed and sealed Clearances Section 3 Pg 7 Combustible materials not installed in non...

Страница 7: ...Top Vent Adapter and 3 to 6 in 76 152mm Offset Adapter 29 3 6 in 741mm 31 1 6 in 788mm C L 5 13 16 in 147mm 3 13 16 in 97mm 14 1 16 in 357mm 2 9 16 in 65mm 28 7 16 in 722mm 32 5 16 in 821mm 28 1 8 in...

Страница 8: ...when installed with horizontal venting or under the Top Vent Adapter with vertical installation CANADA INSTALLATIONS A non combustible floor pro tection extending beneath the flue pipe is required wit...

Страница 9: ...protruding parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in table be...

Страница 10: ...use demand House demand may consume the air needed for the appli ance It may be necessary to add additional ventilation to the space in which the pellet appliance is located Consult with your local HV...

Страница 11: ...y NOTICE HEARTH Home Technologies assumes no responsibility for the improper performance of the chimney system caused by Inadequate draft due to environmental conditions Downdrafts Tight sealing const...

Страница 12: ...ou may use 3 or 4 inch 76 to 102mm diameter type L or PL vent G Pipe Selection Chart The chart will help you in determining proper venting size according to the equivalent feet of pipe calculated prev...

Страница 13: ...NLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference A Alcove Figure 13 1 All minimums listed are to a combustible surface Minimum Maximum...

Страница 14: ...tallation 2 in 51mm Minimum 2 in 51mm Minimum 6 in 152mm Minimum 6 in 152mm Minimum 45 Degree B Through The Wall Horizontal termination cap must be a minimum of 6 inches 152mm from the wall Approved f...

Страница 15: ...ombustible Hearth Pad 3 in 76mm Min Clean out Cover 12 in 305mm Minimum 3 in to 3 in 76 76mm Top Vent Kit Figure 15 3 We recommend a minimum of 60 inches 1524mm vertical however above the eave is pref...

Страница 16: ...to combustible material Figure 16 1 Figure 16 2 Non combustible Hearth Pad Airtight Clean out Door Clean out cover Sheathing 1 in 25mm clearance Flashing Fireclay flue liner with airspace Concrete Cap...

Страница 17: ...PE NOT INCLUDED Tools Needed Phillips head screw driver wire cutters hole saw or jig saw 1 Measure distance from floor to air vent opening in appli ance and mark location on wall Use saw to cut openin...

Страница 18: ...eeded Figure 18 2 4 Install the 5 mounting screws 3 on the left and 2 on the right 5 Drill 2 holes with 26 drill bit through the rear exhaust outlet using the 2 holes already in the short horizontal p...

Страница 19: ...appliance warranty Figure 19 1 Log fits over screws Left Log Log has indentations on the bottom to fit over the screw heads Log rests in front of screws Right Log Figure 19 3 Figure 19 4 E Optional L...

Страница 20: ...ower left corner of the appliance directly above the power cord inlet The center 3 screws are for the wall control thermostat wires and the 2 outer screws are mounting screw and should not have wires...

Страница 21: ...280 Part 24 NEVER INSTALL IN A SLEEPING ROOM WARNING Spark Arrestor Cap Roof Flashing Storm Collar Joist Shield Firestop Approved Class L or PL Pellet Vent Figure 21 1 CAUTION Never draw outside combu...

Страница 22: ...e Air Kit OAK 3 Top Vent Adapter TPVNT 3 Vent Adapter 3 4 811 0720 Vent Adapter 90 Cleanout 811 0610 Vent Adapter Rear 811 0620 Warming Shelves Matte Black 844 9780 Porcelian Black WSLG PBK Porcelian...

Страница 23: ...May 2 2014 7034 277B 23 MT VERNON AE...

Страница 24: ...lle WA 99114 Division of HNI INDUSTRIES Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com This product...

Отзывы: