background image

 2 

 

 

 

 

                        7034-277B 

 

 

 

                 May 2, 2014

MT. VERNON AE

TABLE OF CONTENTS

     Safety Alert Key:

• 

DANGER!

 

Indicates a hazardous situation which, if not avoided will result in death or serious injury.

• 

WARNING!

 Indicates a hazardous situation which, if not avoided may result in death or serious injury.

• 

CAUTION!

 

Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury.

• 

NOTICE:

 Indicates practices which may cause damage to the appliance or to property.

Important Safety Information .............3

A.  Appliance Certification ......................................................3

B.  BTU & Efficiency Specifications........................................3

C.  Glass Specifications .........................................................3

D.  Electrical Rating................................................................3

E.  Mobile Home Approved .................................................... 3

Getting Started ....................................4

A. Design, Installation & Location Considerations  ..........................4

B. Thermostat Wall Control Location......................................5

C.  Tools And Supplies Needed ..............................................5

D. Inspect Appliance and Components  .................................5

E. Install Checklist ..................................................................6

Dimensions and Clearances ..............7

A.  Appliance Dimensions ......................................................7

B. Clearances to Combustibles (UL and ULC) .......................8

C. Hearth Pad Requirements (UL and ULC) ..........................8

Vent Information ..................................9

A.  Venting Termination Minimum Requirements ...................9

B. Avoiding Smoke and Odors ...............................................10

C. Negative Pressure .............................................................11

D. Draft ........ ..........................................................................11

E. Chimney and Exhaust Connection  ...................................11

F. Equivalent Feet of Pipe  .....................................................12

G. Pipe Selection Chart .........................................................12

Venting Systems ...............................13

A.  Alcove 13

B.  Through The Wall .............................................................14

C.  Vertical into Existing Class A Chimney .............................15

D. Through The Wall & Vertical - Exterior ..............................15

E. Vertical - Interior - Typical Installation ................................15

F.  Masonry.............................................................................16

G.  Alternate Masonry ............................................................16

Appliance Set-Up ..............................17

A.  Leg Leveling System  .......................................................17

B. Outside Air Kit Instructions ................................................17

C. Top Vent Adapter Installation  ............................................18

D. Rear Vent & Rear Vent to Top Vent Adapter Installation ....18

E. Optional Log Set Placement Instructions ..........................19

F.  Wall Control Thermostat Installation .................................20

Mobile Home Installation ..................21

Accessory List ..................................22

300 Watt Igniters come installed in brand new Mt. Vernon AE 

units and are for pellet fuel only. The 380 Watt Igniter is required 

for burning multi-gran fuels and is included in the component 

pack. Multi-fuels include, corn, sunflower seeds, and wheat. 

CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.

PART NAME:

DRAWN BY:

SCALE:

MATERIAL:

SHEET:

PART NUMBER:

REV:

THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING 

DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.

ECO #

DATE

BY

REV

UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE:  (2) PLACE DEC : ± 0.03     (3) PLACE DEC: ± 0.005     ANGLE: ± 2°     FRACTION: ± 1/16

OUTSIDE MATERIAL.

NORMAL DIM & INSIDE MATERIAL.

OUTSIDE APEX

INSIDE APEX  -  DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS

REVISIONS

ITEM

PART NUMBER

PART NAME

QTY

7034-280

MULTI-FUEL IGNITER

THIS IGNITER IS REQUIRED FOR 

BURNING FUELS OTHER THAN 

WOOD PELLETS.

THIS IGNITER CAN ALSO BE USED AS A 

BACKUP FOR WOOD PELLETS.

Содержание MTVERNON-AE-CSB

Страница 1: ...rmation in these instruc tions is not followed exactly a fire may result causing property damage personal injury or death Do not store or use gasoline or other flam mable vapors and liquids in the vic...

Страница 2: ...Alcove 13 B Through The Wall 14 C Vertical into Existing Class A Chimney 15 D Through The Wall Vertical Exterior 15 E Vertical Interior Typical Installation 15 F Masonry 16 G Alternate Masonry 16 6 Ap...

Страница 3: ...Installation other than as instructed by Hearth Home Technologies Installation and or use of any component part not approved by Hearth Home Technologies Operating appliance without fully assembling a...

Страница 4: ...given to Safety convenience traffic flow Placement of the chimney and chimney connector and to minimize the use of chimney offsets Place the appliance where there will be a clear passage for a Listed...

Страница 5: ...is an integral part of the appliance No other wall control or thermostat can be substituted D Inspect Appliance and Components Open the appliance and remove all the parts and articles packed inside th...

Страница 6: ...roper clearance Chimney meets the minimum height requirements Roof flashing installed and sealed Terminations installed and sealed Clearances Section 3 Pg 7 Combustible materials not installed in non...

Страница 7: ...Top Vent Adapter and 3 to 6 in 76 152mm Offset Adapter 29 3 6 in 741mm 31 1 6 in 788mm C L 5 13 16 in 147mm 3 13 16 in 97mm 14 1 16 in 357mm 2 9 16 in 65mm 28 7 16 in 722mm 32 5 16 in 821mm 28 1 8 in...

Страница 8: ...when installed with horizontal venting or under the Top Vent Adapter with vertical installation CANADA INSTALLATIONS A non combustible floor pro tection extending beneath the flue pipe is required wit...

Страница 9: ...protruding parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in table be...

Страница 10: ...use demand House demand may consume the air needed for the appli ance It may be necessary to add additional ventilation to the space in which the pellet appliance is located Consult with your local HV...

Страница 11: ...y NOTICE HEARTH Home Technologies assumes no responsibility for the improper performance of the chimney system caused by Inadequate draft due to environmental conditions Downdrafts Tight sealing const...

Страница 12: ...ou may use 3 or 4 inch 76 to 102mm diameter type L or PL vent G Pipe Selection Chart The chart will help you in determining proper venting size according to the equivalent feet of pipe calculated prev...

Страница 13: ...NLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference A Alcove Figure 13 1 All minimums listed are to a combustible surface Minimum Maximum...

Страница 14: ...tallation 2 in 51mm Minimum 2 in 51mm Minimum 6 in 152mm Minimum 6 in 152mm Minimum 45 Degree B Through The Wall Horizontal termination cap must be a minimum of 6 inches 152mm from the wall Approved f...

Страница 15: ...ombustible Hearth Pad 3 in 76mm Min Clean out Cover 12 in 305mm Minimum 3 in to 3 in 76 76mm Top Vent Kit Figure 15 3 We recommend a minimum of 60 inches 1524mm vertical however above the eave is pref...

Страница 16: ...to combustible material Figure 16 1 Figure 16 2 Non combustible Hearth Pad Airtight Clean out Door Clean out cover Sheathing 1 in 25mm clearance Flashing Fireclay flue liner with airspace Concrete Cap...

Страница 17: ...PE NOT INCLUDED Tools Needed Phillips head screw driver wire cutters hole saw or jig saw 1 Measure distance from floor to air vent opening in appli ance and mark location on wall Use saw to cut openin...

Страница 18: ...eeded Figure 18 2 4 Install the 5 mounting screws 3 on the left and 2 on the right 5 Drill 2 holes with 26 drill bit through the rear exhaust outlet using the 2 holes already in the short horizontal p...

Страница 19: ...appliance warranty Figure 19 1 Log fits over screws Left Log Log has indentations on the bottom to fit over the screw heads Log rests in front of screws Right Log Figure 19 3 Figure 19 4 E Optional L...

Страница 20: ...ower left corner of the appliance directly above the power cord inlet The center 3 screws are for the wall control thermostat wires and the 2 outer screws are mounting screw and should not have wires...

Страница 21: ...280 Part 24 NEVER INSTALL IN A SLEEPING ROOM WARNING Spark Arrestor Cap Roof Flashing Storm Collar Joist Shield Firestop Approved Class L or PL Pellet Vent Figure 21 1 CAUTION Never draw outside combu...

Страница 22: ...e Air Kit OAK 3 Top Vent Adapter TPVNT 3 Vent Adapter 3 4 811 0720 Vent Adapter 90 Cleanout 811 0610 Vent Adapter Rear 811 0620 Warming Shelves Matte Black 844 9780 Porcelian Black WSLG PBK Porcelian...

Страница 23: ...May 2 2014 7034 277B 23 MT VERNON AE...

Страница 24: ...lle WA 99114 Division of HNI INDUSTRIES Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com This product...

Отзывы: