background image

 6 

 

 

 

 

                     7036-187C  

 

 

 

                June 18, 2014

MT. VERNON AE INSERT

Emissions Rating:

EPA Compliance

*BTU Input:

14,620 - 60,200 / hr

Effi ciency:

Up to 86.5%

Heating Capacity:

Up to 3,000 square feet depending 
on climate zone

Vent Size:

3” or 4” Type “L” or “PL”

Hopper Capacity:

56 lbs +/-5 lbs

Fuels:

Pellets, Shelled Field Corn, Wheat 
and Black Sunfl ower Seeds

Shipping Weight:

425 lbs

*BTU will vary, depending on the type of fuel you use in your 
appliance.  Consult your Quadra-Fire dealer for best results.

C.  Glass Specifi cations

This stove is equipped with 5mm ceramic glass.  Replace 
glass only with 5mm ceramic glass.  Please contact your 
dealer for replacement glass.

D.  Electrical Rating

115 VAC, 60 Hz, Start 5 Amps, Run 1.25 Amps

Model

Mt. Vernon Pellet Insert AE

Laboratory

OMNI Test Laboratories, Inc.

Report No.

061-S-69-6

Type

Solid Fuel Room Heater/Pellet Type 

Insert

Standard

ASTM E1509-04, ULC S628-93 and 
ULC/ORD-C1482-M1990 Room Heater 
Pellet Fuel Burning type and (UM) 
84-HUD, Mobile Home Approved.

FCC

Complies with Part 15 of FCC Rules. 
Operation is subject to the following 
two conditions:  (1) this device may not 
cause harmful interference, and (2) this 
device must accept any interference 
received, including interference that may 
cause undesired  operation.

•  Installation and use of any damaged appliance. 

• Modifi cation of the appliance.

•  Installation other than as instructed by Hearth & Home 

Technologies.

•  Installation and/or use of any component part not approved by 

Hearth & Home Technologies.

•  Operating appliance without fully assembling all components.

•  Operating appliance without legs attached (if supplied with unit).

•  Do NOT Overfi re - If appliance or chimney connector glows, 

you are overfi ring.

Any such action that may cause a fi re hazard.

Listing and Code Approvals

A.  Appliance Certifi cation

NOTE:  Hearth & Home Technologies, manufacturer of 
this appliance, reserves the right to alter its products, their 
specifi cations and/or price without notice.

NOTICE:  

This installation must conform with local codes. In 

the absence of local codes you must comply with the 

ASTM 

E1509-04, ULC S628-93, (UM) 84-HUD and  ULC/ORD-
C-1482-M1990. 

Improper installation, adjustment, alteration, service or 
maintenance can cause injury or property damage. 
For assistance or additional information, consult a qualifi ed 
installer, service agency or your dealer.

Quadra-Fire is a registered trademark of Hearth & Home 
Technologies.

WARNING

Fire Risk.

Hearth & Home Technologies disclaims any 
responsibility for, and the warranty will be voided by, 
the following actions: 

B.  BTU & Effi ciency Specifi cations

E.  Mobile Home Approved 

 • 

This appliance is approved for mobile home installa-
tions when not installed in a sleeping room and when 
an outside combustion air inlet is provided.

 • 

The structural integrity of the mobile home fl oor, ceil-
ing, and walls must be maintained.  

 • 

The appliance must be properly grounded to the 
frame of the mobile home and use only Listed pellet 
vent Class “L” or “PL” connector pipe.  

 • 

Outside Air Kit, part OAK-ACC must be installed in a 
mobile home installation.

Содержание MTVERNINSAE-MBK

Страница 1: ...the information in these instruc tions is not followed exactly a fire may result causing property damage personal injury or death Do not store or use gasoline or other flam mable vapors and liquids i...

Страница 2: ...d operating instructions Contact local building or fire officials about restrictions and inspection in our area WARNING FOR MOBILE HOMES Do not install appliance in a sleeping room An outside combusti...

Страница 3: ...e 9 I Fire Characteristics Flame Height Adjustment 9 J Battery Back up System Optional 10 K Clear Space 10 L Ignition Cycles 11 M Insert Removal 12 N Frequently Asked Questions 13 3 Wall Control Opera...

Страница 4: ...uction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier...

Страница 5: ...T VERNON AE INSERT WARRANTY CONDITIONS This warranty is void if LIMITATIONS OF LIABILITY 8 K N N OQ R U Z 8 88 U 8 U Q 8 N N Q Z R N U Q 8 R Z N N 88 N U Q 8 N O K WARRANTY EXCLUSIONS N Z N _ q _ q _...

Страница 6: ...omponent part not approved by Hearth Home Technologies Operating appliance without fully assembling all components Operating appliance without legs attached if supplied with unit Do NOT Overfire If ap...

Страница 7: ...ogies strongly recommends only using Pellet Fuel Institute PFI certified fuel Fuel Material Made from sawdust or wood by products Shelled field corn other biomass fuels Depending on the source materia...

Страница 8: ...the clearance requirements or in an area that would hinder routine cleaning and maintenance E General Operating Information 1 Thermostat Wall Control Automatic Setting The appliance is like most moder...

Страница 9: ...ermocouple cover or missed ignitions can occur G Filling the Hopper with Fuel Check the hopper and make sure it is empty before filling with fuel Open the cast top hopper lid Do not over fill the hopp...

Страница 10: ...ain Recommended Battery 12 volt deep cycle battery i e marine or RV type A 12 volt battery cable is available through your local dealer 13 Volts 12 Volts 11 Volts Battery Below 10 Volts Figure 10 1 K...

Страница 11: ...your set temperature the appli ance will go into the shutdown cycle Manual Mode Set the heat output setting from the main screen The right bottom button will read HEAT OUTPUT You can operate the appl...

Страница 12: ...ected MAINTENANCE BURN This indicates the appliance is operating on battery backup prior to the auto clean The maintenance burn will keep the system from shutting down as the appliance will not automa...

Страница 13: ...ith black tails and is lazy 4 The flame height adjustment needs to be reduced or the firepot needs cleaning Heat exchanger or exhaust blower needs cleaning 5 Excessive smokey start up 5 Either the fir...

Страница 14: ...t status of the system It indicates if the system is running in automatic or manual cycle if it is turned on or off and where it is in the operating sequence a START UP Indicates that the appliance is...

Страница 15: ...work call your dealer E The Main Menu The menu is the heart of customizing the operation of the pellet appliance system to your personal liking The choices on this menu are 1 Set Comfort Level Temper...

Страница 16: ...you are burning a high ash fuel set the fuel selec tion to Utility Pellets When purchasing corn or wheat to burn in your appliance read the ingredient label very carefully Do NOT purchase fuel that co...

Страница 17: ...er month then press the button under Set Next The highlight will move to the day of the month display Using the UP DOWN buttons select the current date then press Set Next The highlight will move to t...

Страница 18: ...you to adjust the appliance to your specific elevation Press the UP DOWN buttons to select your elevation The message in the center will change between NORMAL and HIGH If you select HIGH it will repl...

Страница 19: ...hopper lid and glass door are both closed 1 At the starting screen press MENU Function Buttons Buttons Up Down Wall Control for Reference 6 Press DONE twice or wait 15 sec onds for starting screen to...

Страница 20: ...ICE RETRY ERROR LIST 1 If the appliance has stopped operat ing check the wall control screen If it is showing Min Firepot Temp the hopper has run out of fuel 2 Fill the hopper with fuel and press the...

Страница 21: ...iance will no longer automatically light See page 10 Use only approved fire starting gel to start fire High burn rate is no longer available on battery back up Each level drops down one level i e the...

Страница 22: ...s will void your warranty Follow the detailed instructions found in this section for each step listed in the chart below Cleaning or Inspection Frequency Daily Weekly Every 2 Weeks Monthly Yearly Ash...

Страница 23: ...very ton aprx 50 bags or more frequently depending on the type of fuel By Homeowner a Be sure the wall control screen says OFF and the appliance is allowed to cool b Open the firebox door Inspect the...

Страница 24: ...e fully closed when finished 6 Cleaning Heat Exchanger Drop Tube Exhaust Frequency Monthly or every 1 ton of fuel aprx 50 bags By Homeowner NOTE There are heavy duty vacuum cleaners specifically desig...

Страница 25: ...ength to your vacuum hose 3 Use a bottle brush and push the ash down to the bottom Remove the combustion exhaust blower and then vacuum out the ash NOTE It is normal to see a certain amount of wear of...

Страница 26: ...aned at least once a year or more often depending upon the quality of your fuel or if there is a lot of horizontal pipe sections Ash will build up more quickly in the horizontal sections 11 Preparing...

Страница 27: ...nough Another symptom is if clinkers are adhering to the sides of the firepot Double check the wall control to ensure the proper setting has been selected for the fuel you are burning If that is corre...

Страница 28: ...ect Clear jam and Press Retry MISSED IGNITION Igniter bad or poor harness connection Out of fuel or fuel is bridging in hopper Faulty firepot thermocouple connection has shorted Ash plugging the ignit...

Страница 29: ...ce If it is not centered the latch is trapped between the baffle and side of the firebox instead of latching properly g The bottom of the latches will fit over the posts Push the top of the latch forw...

Страница 30: ...eplace the side set the bottom in first Squeeze the latch in an open position Place the cast side into posi tion and then release the latch The latch hooks onto a bracket to hold the side in place Con...

Страница 31: ...the cast side An icon will display on the wall control when the appliance has lost main power and is running on battery back up 4 Combustion Exhaust Blower The combustion exhaust blower is mounted in...

Страница 32: ...Thermocouple Drop Tube This thermocouple is located on the bottom of the drop tube on the right side and attached with a wing nut It turns the convection blower on and off varies the speed of the conv...

Страница 33: ...affle Ash Pan Firepot Thermocouple Thermocouple Cover Baffle Firepot Ash Pan Thermocouple and Thermocouple Cover Heat Exchanger Front Back Power Supply Control Board Convection Blower Drop Tube Low Fu...

Страница 34: ...cturing Date Sept 2006 Ending Manufacturing Date Active Advanced Energy Pellet Insert MTVERNINSAE CSB MTVERNINSAE MBK MTVERNINSAE PMH MTVERNINSAE CWL Sept 2006 thru June 2011 Part number list on follo...

Страница 35: ...ded Field Cut to Size 10 Ft 7000 320 10 4 Catch Clip 7036 146 5 Elbow Catch 7000 393 6 Bracket Catch 7036 145 7 Glass Assembly Side 1 Piece 5 7 8 in W x 9 in H Interchangeable 414 5380 Y Gasket Channe...

Страница 36: ...atch Assembly 7034 039 19 6 Glass Assembly 21 W x 14 H 7034 007 Y Gasket Channel 3 Mm X 32 Field Cut to Size 10 Ft 7000 377 10 Y Tape Door Corner Field Cut to Size 1 Ft SRV7027 227 Y 19 7 Glass Retain...

Страница 37: ...Between Housing Motor SRV7000 714 Y 31 Control Board Assembly SRV7000 456 Y Fuse 15A Slow Iec Glass Pkg of 10 7000 491 10 Y 32 Convection Blower SRV7000 260 Y 33 Gasket Blower Convection 7000 329 34 D...

Страница 38: ...39 4 Firepot Assembly SRV7034 072B Y 39 5 Gasket Firepot 7034 190 Y 39 6 Auto Clean Link Arm 7034 176 Y 39 7 Plow Weldment Auto Clean 7034 024 Y 39 8 Rail Auto Clean SRV7034 152 Y 39 9 Spring Pkg of 4...

Страница 39: ...h Up Paint and Label If Fireplace Altered Matte Black 7036 018 Sienna Bronze 7036 019 Willow 7036 020 Mahogany 7036 021 Cleanout Tool 414 1140 Y Dvd Advanced Energy 7000 335 Paint Touch Up Matte Black...

Страница 40: ...ire Harness Ignitor SRV7034 273 Y Wire Harness Power Out Ac AC Current 7034 220 Y Wire Harness Power Out Dc DC Current 7034 221 Y Wire Harness Power Supply Receptacle SRV7034 233 Y Wire Harness Snap D...

Страница 41: ...Y Outside Air Kit OAK 3 Surround Std Panel For Cast Trim SP MTVS CST Component Pack 7036 041 Surround Std Panel w Gold Trim SP MTVS GD Component Pack 7036 042 Trim Panel Set Gold 250 4660 Surround St...

Страница 42: ...42 7036 187C June 18 2014 MT VERNON AE INSERT E Homeowner s Notes...

Страница 43: ...June 18 2014 7036 187C 43 MT VERNON AE INSERT...

Страница 44: ...ille WA 99114 Division of HNI INDUSTRIES Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com This produc...

Отзывы: