background image

 14

 

 

 

 

 

                         7061-196H 

 

 

 

 

June 9, 2017

Explorer II

Optional Blower 

Chimney System

Firebrick & Ash Removal

Door & Glass Assemblies

Door Handle

Frequency

MONTHLY,

After Every 

Cord of Wood,

OR

After Each 

Cleaning

YEARLY

Vacuum the blower impellers.

EVERY 2 

MONTHS

or

After Every 

2 Cords of 

Wood

The chimney and chimney cap must be inspected for 

soot and creosote every two months during the burn 

season or more frequency if chimney exceeds or is 

under 14-16 ft (4.3m-4.8m) measured from bottom of 

appliance.
This will prevent pipe blockage, poor draft, and chim-

Always burn dry wood to help prevent cap blockage 

and creosote build-up.

WEEKLY

or

After Every 

25 Loads of 

Wood

WEEKLY

or

After Every 

25 Loads of 

Wood

Keep door and glass gasket in good shape to maintain 

good burn times on a low burn setting. To test: place 

a dollar bill between the appliance and door and then 

shut the door.  If you can pull the dollar out, remove 

one washer from door handle behind latch cam and 

try again.  If you can still pull it out, replace the door 

gasket.

Check the glass frame for loose screws to prevent air 

leakage. Check glass for cracks.

YEARLY

Check the door latch for proper adjustment.  This 

is very important especially after the door rope has 

formed to the appliance face.
Check door handle for smooth cam operation.

Task

Baffle

Blanket

Ashes must be cool before you can dispose of the 

ashes in a non-combustible container.

-

broken.

 

CAUTION!

 

  Allow  the  appliance  to  completely  cool 

down before performing any cleaning or maintenance. 

These are generic drawings and may not represent your model.

performance changes, and adjust your schedule according-

ly.  Maintenance is required for safe operation and must be 

performed to maintain your warranty.

Floor

Protector

Chimney

Connector

Ceiling Support

Listed Chimney

Listed Termination Cap

Storm Collar

Flashing

A. Quick Reference Maintenance Guide

Maintenance and Service

Содержание EXPLRMED-PBK

Страница 1: ...aterials away WARNING If the information in these instruc tions is not followed exactly a fire may result causing property damage personal injury or death Do not store or use gasoline or other flam ma...

Страница 2: ...A chimney suitable for use with solid fuels or a masonry chimney and the referenced clearances DOUBLE WALL Six inch 6 inches 152mm diameter listed double wall air insulated connector pipe with listed...

Страница 3: ...s 7 C Mobile Home Approved USA ONLY 7 D Glass Specifications 7 2 Operating Instructions 8 A Over Firing Your Appliance 8 B Wood Selection Storage 8 C Burning Process 8 D Automatic Combustion Control A...

Страница 4: ...y coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty s...

Страница 5: ...ot cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is...

Страница 6: ...he door after the fire has started and after refueling to prevent Spillage of smoke flame and carbon monoxide Spillage of sparks coals and logs Over firing DO NOT leave the appliance unattended with t...

Страница 7: ...ing all components Operating appliance without legs attached if supplied with appliance Do NOT Over fire If appliance or chimney connector glows you are over firing Any such action that may cause a fi...

Страница 8: ...p plastic tar paper sheets of scrap plywood etc as uncovered wood can absorb water from rain or snow delaying the seasoning process C Burning Process In recent years there has been an increasing conce...

Страница 9: ...ire situation and or burning your wood up too quickly before you shut down the air controls to the desired burn rate With the Automatic Combustion Control ACC system you do not have to continually mon...

Страница 10: ...there are hot coals repeating steps 6 through 8 will maintain a continuous fire throughout the season F Burn Rates and Operating Efficiency For maximum operating efficiency This wood appliance has a...

Страница 11: ...rd Figure 11 2 Figure 11 1 CORRECT POSITION WARNING Fire Risk Firebox damage due to improper baffle placement is not covered by warranty Operate the wood burning appliance with the baffle in the corre...

Страница 12: ...d by the smoke column from a chimney and 0 opacity means that no smoke column can be seen As you become familiar with your appliance you should periodically check the opacity This will allow you to kn...

Страница 13: ...appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting should be a sealed can design Attic hatches weather stripped or sealed Attic mounted duct work a...

Страница 14: ...r and then shut the door If you can pull the dollar out remove one washer from door handle behind latch cam and try again If you can still pull it out replace the door gasket Check the glass frame for...

Страница 15: ...t has accumulated it should be removed to reduce the risk of a chimney fire a The appliance and ashes must be completely cooled down before using the Ash Removal System Reach down and locate the ash r...

Страница 16: ...lowing over the glass and the smokey relatively cool condition of a low fire will cause the glass to become coated Operating the appliance with the Burn Rate Air Control and Start UpAir Control all th...

Страница 17: ...y or soft wood Over drafting Use dry kindling and more paper arrange kingling and wood for better air movement Check for restricted termination cap Check for blockage of outside air kit if installed C...

Страница 18: ...tely a few turns at a time until the glass is secure DO NOT OVER TIGHTEN 9 Replace the door on the appliance Quadra Fire appliances are equipped with ceramic super heat resistant glass which can only...

Страница 19: ...all hot embers before disposal into a metal container 2 The baffle board has 2 pieces With the ceramic blanket still in place slide one baffle piece over the top of other one and pull out top piece t...

Страница 20: ...channel nuts 7 16 and 2 bolts 3 8 inside of chamber Figure 20 2 4 Slide the tube channel assembly all the way to left until it is off the threads Drop the right side down then slide the assembly back...

Страница 21: ...June 9 2017 7061 196H 21 Explorer II Date of Service Performed By Description of Service A Service Maintenance Log 6 Reference Materials...

Страница 22: ...22 7061 196H June 9 2017 Explorer II Date of Service Performed By Description of Service...

Страница 23: ...rt number list on following page 03 17 Color SKU No Mfg Dates Matte Black EXPLRMED MBK 03 14 Porcelain Black EXPLRMED PBK 10 14 Porcelain Dark Blue EXPLRMED PDB 10 14 Porcelain Frost EXPLRMED PFT 10 1...

Страница 24: ...ansition Assembly SRV29138 5 Top Matte Black 7061 101MBK Porcelain Black 7061 101PBK Porcelain Dark Blue 7061 101PDB Porcelain Frost 7061 101PFT Porcelain Mahogany 7061 101PMH 6 Side Left Matte Black...

Страница 25: ...y 1 req 11 5 Brick 5 w angle 9 X 4 5 X 1 25 Qty 2 req 11 6 Brick 6 6 69 X 3 5 X 1 25 Qty 2 req Brick Uncut Must specilfy size when ordering Pkg of 1 832 0550 Pkg of 6 832 3040 12 Ashlip Matte Black 70...

Страница 26: ...1151 14 Front Matte Black 7061 103MBK Porcelain Black 7061 103PBK Porcelain Dark Blue 7061 103PDB Porcelain Frost 7061 103PFT Porcelain Mahogany 7061 103 Gasket 7 16 844 3980 15 Andirons 2 pcs SRV7061...

Страница 27: ...061 033 Porcelain Mahogany SRV7061 028 Leveling Assembly 7000 000 Paint Touch Up Matte Black 812 0910 Porcelain Black 1 00 0022 Porcelain Dark Blue 1 00 0020 Porcelain Frost 1 00 0021 Porcelain Mahoga...

Страница 28: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deale...

Отзывы: