background image

November 29, 2016 

 

 

 

 

 7060-228G 

 

 

 

         

                  5

Explorer III Wood Stove

Screws 

x4

Ash pan

Pallet 

Attach 

Bracket

Ash Pan 

Retention Bracket

D.  Tools And Supplies Needed

Before beginning the installation be sure the following tools 

and building supplies are available:

Reciprocating saw 

Framing material

Pliers 

High temp caulking material

Hammer 

Gloves

Phillips screwdriver 

Framing square

Flat blade screwdriver  Electric drill and bits
Plumb line 

Safety glasses

Level 

Tape measure

Misc. screws and nails
1/2-3/4 in. length, #6 or #8 self-drilling screws

•  Remove appliance and components from packaging and 

inspect for damage.

•  Report to your dealer any parts damaged in shipment.

•  Read all the instructions before starting the installation. 

Follow  these  instructions  carefully  during  the 

installation to ensure maximum safety and benefit.

E.  Inspect Appliance and Components

Fire Risk

Inspect appliance and components for damage. 

Damaged parts may impair safe operation.

WARNING

•  Do NOT install damaged components.

•  Do NOT install incomplete components.

•  Do NOT install substitute components.

Report damaged parts to dealer.

•  Installation and use of any damaged appliance. 
•  Modification of the appliance.
•  Installation  other  than  as  instructed  by  Hearth  &  Home 

Technologies.

•  Installation and/or use of any component part not approved 

by Hearth & Home Technologies.

•  Operating appliance without fully assembling all components.
•  Operating appliance without legs attached (if supplied with 

appliance).

•  Do NOT Over fire - If appliance or chimney connector glows, 

you are over firing.

Any such action that may cause a fire hazard.

WARNING

Fire Risk.

Hearth & Home Technologies disclaims any 

responsibility for, and the warranty will be voided 

by, the following actions: 

To minimize the effects of negative air pressure:

•  Install the outside air kit with the intake facing prevailing 

winds during the heating season

•  Ensure adequate outdoor air for all combustion appliances 

and exhaust equipment

•  Ensure furnace and air conditioning return vents are not 

located in the immediate vicinity of the appliance

•  Avoid installing the appliance near doors, walkways or 

small isolated spaces

•  Recessed lighting should be a “sealed can” design
•  Attic hatches weather stripped or sealed
•  Attic mounted duct work and air handler joints and seams 

taped or sealed

•  Basement installations should be avoided 

1.  Remove box and 2x4 structural boards being careful 

not to damage product.

2.  Using a Phillips screw driver, remove and discard the 

4 screws and ash pan retention bracket from front of 

appliance 

(Figure 5.1)

.

3.  Remove ash pan and set aside 

(Figure 5.1)

.

4.  Remove and discard the pallet attach bracket 

(Figure 

5.1)

5. Using a 3/8 socket or open end wrench, remove two 

bolts on back side as shown 

(Figure 5.2)

.

6. Slide appliance forward off of pallet support brackets

.

7. Replace ash pan 

(Figure 5.1).

F.  Removal of Appliance from Shipping 

Materials

Figure 5.1

Bolts 

x2

Figure 5.2

Содержание EXPLR-III-MBK

Страница 1: ...ns Do not touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away WARNING Installation Manual Installation Appliance Set ...

Страница 2: ...ifications 3 E Non Combustible Materials 3 F Combustible Materials 3 2 Getting Started 4 A Design and Installation Considerations 4 B Fire Safety 4 C Negative Pressure 5 D Tools And Supplies Needed 5 E Inspect Appliance and Components 5 F Removal of Appliance from Shipping Materials 5 F Install Checklist 6 3 Dimensions and Clearances 7 A Appliance Dimensions 7 B Hearth Protection Requirements 8 C ...

Страница 3: ...ts Material which will not ignite and burn composed of any combination of the following Steel Plaster Brick Iron Concrete Tile Glass Slate Materials reported as passing ASTM E 136 Standard Test Method for Behavior of Metals in a Vertical Tube Furnace of 750 C NOTE This installation must conform with local codes In the absence of local codes you must comply with the UL1482 11 UL 737 11 UM 84 HUD an...

Страница 4: ...ce or air conditioning Imbalances of the HVAC air handling system Upper level air leaks such as Recessed lighting Attic hatch Duct leaks WARNING Asphyxiation Risk Negative pressure can cause spillage of com bustion fumes soot and carbon monoxide Appliance needs to draft properly for safety Check building codes prior to installation Installation MUST comply with local regional state and national co...

Страница 5: ...ithout fully assembling all components Operating appliance without legs attached if supplied with appliance Do NOT Over fire If appliance or chimney connector glows you are over firing Any such action that may cause a fire hazard WARNING Fire Risk Hearth Home Technologies disclaims any responsibility for and the warranty will be voided by the following actions To minimize the effects of negative a...

Страница 6: ...onsible for use and operation ATTENTION INSTALLER Follow this Standard Work Checklist This standard work checklist is to be used by the installer in conjunction with not instead of the instructions contained in this installation manual Customer __________________________________________________________________________ Date Installed _________________________________________________________________...

Страница 7: ... Figure 7 1 Front View Figure 7 2 Side View 8 3 16 28 5 16 31 3 8 13 1 16 20 1 16 Figure 7 2 Top View 30 1 8 3 28 5 8 24 1 8 Center of Flue Figure 7 4 Side View with horizontal flue 3 Dimensions and Clearances A Appliance Dimensions NOTE Flue Collar size is 6 inch 152mm diameter ID ...

Страница 8: ... door and measure 8 inches 203mm from the side edge of the opening in the face of the appliance See exception In Canada similar floor protection must be provided 18 inches 457mm in front and 8 inches 203mm from the sides and rear of the appliance Figure 8 2 EXCEPTION Non combustible floor protections must extend beneath the flue pipe when installed with horizontal venting and extend 2 inches 51mm ...

Страница 9: ... 1 2 241 6 153 27 686 12 305 N A N A 52 1 2 1334 18 457 INSTALLATION HORIZONTAL THROUGH THE WALL SINGLE WALL PIPE N A N A 43 1 2 1105 25 1 2 648 N A N A 52 1 2 1334 N A For alcove only Six inch diameter listed Double wall air insulated connector pipe with UL103 HT listed factory built Class A chimney or masonry chimney Maximum depth of Alcove shall be no more than 48 inches 1219mm and the referenc...

Страница 10: ...imney should Install through the warm space enclosed by the build ing envelope This helps to produce more draft espe cially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind turbulence and down drafts Consider the appliance location in order to avoid floor and ceiling attic joists and rafters Locate termination cap away from trees ad...

Страница 11: ...mum 3 ft 91cm Minimum Wall or Parapet Flat Roof F 2 10 3 Rule These are safety requirements and are not meant to assure proper flue draft This appliance is made with a 6 inch 152mm diameter chimney connector as the flue collar on the appliance Changing the diameter of the chimney can affect draft and cause poor performance It is not recommended to use offsets and elbows at altitudes above 4000 fee...

Страница 12: ...eel black or 26 gauge blued steel or an approved air insulated double wall venting pipe Thimble A manufactured or site constructed device installed in combustible walls through which the chimney connector passes to the chimney It is intended to keep the walls from igniting Site constructed thimbles must meet NFPA 211 Standards Prefabricated must be suitable for use with selected chimney and meet U...

Страница 13: ...side dimension frame from 2 x 2 framing lumber to fit into wall opening Inside opening of frame should be no less than 14 inch x 14 inch 356mm x 356mm Figure 13 1 4 Attach the wall spacer to the chimney side of the frame 5 Nail the frame into the wall opening The spacer should be on the chimney side 6 Insert the section of the solid insulated chimney into the outer wall of the masonry chimney 7 Ti...

Страница 14: ...appliance in a mobile home The listed connectors must conform to each other to ensure a proper fit and seal Flue Gas Direction Crimped End Toward Appliance Secure pipe sections with a minimum of 3 screws Figure 14 2 Chimney Connector Appliance Pipe WARNING Asphyxiation Risk DO NOT CONNECT THIS Appliance TO A CHIM NEY FLUE SERVICING ANOTHER APPLIANCE DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR S...

Страница 15: ...pter to the appliance using 4 screws Figure 15 1 15 2 3 Floor Rear Installation Cut a 4 inch 102mm hole in outside wall or floor to accommodate outside air piping Use 4 inch 102mm aluminum metal flex or rigid piping to directly connect outside air to appliance intake Use the supplied termination cap with a rodent screen Seal between the wall or floor and the pipe with silicone to prevent moisture ...

Страница 16: ...net under the bottom left rear corner See Owner s Manual for detailed operating instructions for the blower and snap disc Shock Risk Do NOT remove grounding prong from plug Route cord away from appliance Do NOT route cord under or in front of appliance Plug directly into properly grounded 3 prong receptacle CAUTION MANUAL Overides the Snap Disc AUTO Fan will turn ON OFF Automatically by the Snap D...

Страница 17: ...bolt from each side of the flue transition and retrieve nuts attached to bolts 3 Turn flue transition to horizontal position Inspect rope gasket to ensure a leak free seal Re attach 4 Remove upper flue cover from convection chamber top Rotate 180 degrees and reassemble Use paint supplied to cover unpainted areas 5 Reattach convection chamber top to flue collar to appli ance Figure 17 2 D Optional ...

Страница 18: ... inch 152mm factory built chimney conforming to CAN ULC 629M STANDARD FOR FACTORY BUILT CHIMNEYS 6 Follow the chimney and chimney connector manufacturer s instructions when installing the flue system for use in a mobile home 7 Maintain clearance to combustibles 8 Floor protection requirements must be followed precisely 9 Use silicone to create an effective vapor barrier at the location where the c...

Страница 19: ...nsulation Blanket SRV7060 238 30 2 Baf e Blanket SRV7060 233 Y 30 3 Baf e Plate SRV7060 250 30 4 Baf e Board SRV7060 148 Y 30 5 Secondary Tubes Qty 3 req SRV7060 226 Y 30 6 Baf e Cover Plates SRV7060 206 30 7 Baf e Linkage SRV7060 044 31 Side Right Matte Black 7060 033MBK Porcelain Mahogany 7060 033PMH Porcelain Dark Blue 7060 033PDB Porcelain Black 7060 033PBK Porcelain Frost 7060 033PFT 32 Manif...

Страница 20: ...peration DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com CONTACT INFORMATION This product may be covered by one or more of the following patents United States 5341794 5263471 6688302 7216645 7047962 or other U S and foreign patents pending We recommend that you record the following pe...

Отзывы: