background image

18

7060-801A

April 26, 2019

Explorer III AU Wood Appliance

Flex Line 

Wire Tie 

Wire Tie 

Flex Adapter 

Termination 

Cap 

For Floor Installa-

tions Remove 

Circular “Knock-Out” 

in Base of Pedestal.

Figure 18.2

Cover

Plate

Rope to Seal

Pedestal

Items Needed for Installation (not supplied)

 -

102mm flex aluminum pipe, or if using alternate 

material, then it shall be made from durable, 

non-combustible, heat resistant material up to 

350°F. Cut the pipe to the required length for 

your installation. 

 - Phillips head screw driver 

 - Silicone sealant

 - Drills and saws necessary for cutting holes through 

the wall or flooring in your home.

1. 

Remove all materials from packing box.

2. 

Using a #2 Phillips screw driver attach the flex adapter 

to the appliance using 4 screws 

(Figure 18.1)

 

3. 

For floor installations, remove circular” knock-out” in the 

base of the pedestal.

4.  Floor & Rear Installation:

Cut a 102mm hole in outside wall or floor to 

accommodate outside air piping. Use 102mm 

aluminum metal flex or rigid piping to directly connect 

outside air to appliance intake. Use the supplied 

termination cap with a rodent screen. Seal between 

the wall (or floor) and the pipe with silicone to prevent 

moisture penetration.

5.  Floor Installation Alternative:

In some instances you may not be able to install the 

flex pipe as show in 

Figure 18.1

. If that is the case, you 

will need to order SRV7033-041 which includes a cover 

plate and sealing rope as shown in 

Figure 18.2

. The 

goal is to seal the pedestal so no room air can leak into 

the pedestal or for cold air infiltration. 

A. Outside Air Kit Installation 

A source of air (oxygen) is necessary in order for 

combustion to take place. Whatever combustion air is 

consumed by the fire must be replaced. Air is replaced via 

air leakage around windows and under doors. In homes 

that have tightly sealed doors and windows, an outside air 

source is needed. An optional Outside Air Kit is available. 

Included in OAK-ACC: 

Termination cap, (2) wire ties, flex adapter, and fasteners

Included in SRV7033-041:

Cover plate and sealing rope (see Floor Installation 

Alternative below, 

Figure 18.2

)

Figure 18.1 - Floor & Rear Installation

Appliance Set-Up

WARNING

Fire Risk. Asphyxiation Risk.

Do not draw outside combustion air from:

• 

Wall, floor or ceiling cavity

•  Enclosed space such as an attic 

or garage

• 

Close proximity to exhaust vents 

or chimneys

Fumes or odor may result

WARNING

Asphyxiation Risk.

Outside air inlet must be located to prevent 

blockage from:

•  Leaves

•  Snow or ice

• 

Other debris

Block may cause combustion air starvation. 

Smoke spillage may set off alarms or irritate 

sensitive individuals.

Asphyxiation Risk.

Length of outside air supply duct shall NOT 

exceed the length of the vertical height of the 

exhaust flue.

• 

Fire will not burn properly

•  Smoke spillage occurs when door is 

opened due to air starvation

WARNING

Содержание EXPIII-MBK-APAC

Страница 1: ...same room as appliance Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away WARNING Fire Risk For use with solid wood fuel only Other fuels may over fire and generate poisonous gases i e carbon monoxide Do not store or use gasoline or other flammable vapors a...

Страница 2: ... Exit 12 C Chimney Termination Requirements 13 D General Flue System Instructions 14 E Chimney Height Rise and Run 14 F Installing Chimney Components 14 G Proper Draft 14 H 6 8 10 Freestanding Triple Skin System 15 I Tested Flue Systems 16 J Un Tested Flue Systems 17 5 Appliance Set Up 18 A Outside Air Kit Installation 18 6 AS NZS 2918 2018 General Notes 19 7 Reference Materials 20 A Service and M...

Страница 3: ...on and must be fitted Vent Size 6 inches Firebox Size 3 00 cubic feet Recommended Wood Length 18 inches Fuel Orientation Side to Side Approved Fuel Hardwood only with a Moisture content less than 25 dry basis Model Explorer II AU Wood Appliance Laboratory Australian Solid Fuel Testing ASFT Report No ASFT19001 Report Test Date 10 January 2019 Type Hardwood less than 25 dry basis Standard AS NZS 291...

Страница 4: ... Tile Glass Slate E Combustible Materials Material made of or surfaced with any of the following materials Wood Compressed Paper Plant Fibers Plastic Plywood OSB Sheet Rock drywall Any material that can ignite and burn flame proofed or not plastered or non plastered Installation and use of any damaged appliance Modification of the appliance Installation other than as instructed by Hearth Home Tech...

Страница 5: ... evacuation plan consisting of at least two escape routes 5 A plan to deal with a chimney fire as follows 6 In the event of a chimney fire a Evacuate the house immediately b Notify fire department C Negative Pressure Negative pressure results from the imbalance of air available for the appliance to operate properly It can be strongest in lower levels of the house Causes include Exhaust fans kitche...

Страница 6: ...inity of the appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting should be a sealed can design Attic hatches weather stripped or sealed Attic mounted duct work and air handler joints and seams taped or sealed Basement installations should be avoided Installation and use of any damaged appliance Modification of the appliance Installation other tha...

Страница 7: ...der the appliance and given to the party responsible for use and operation Hearth Home Technologies recommends the following Photographing the installation and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installtion is complete Comments Further description of the issues who is responsible Installer Builder Other Trades etc and cor...

Страница 8: ... 8 613mm Center of Flue 33 1 8 841mm Top of Flue Figure 8 1 Front View Figure 8 2 Side View Figure 8 4 Side View 28 1 4 718mm 31 3 8 797mm 13 330mm 20 508mm 30 1 8 765mm Figure 8 2 Top View 15 1 4 387mm 2 1 4 70mm 3 8 10mm A Appliance Dimensions NOTE Flue Collar size is 152mm inside diameter ID 3 Dimensions and Clearances ...

Страница 9: ...e floor protector should extend 320mm in front of the appliance door and be placed centrally in the 885mm width The Thermal resistivity of the floor protector is 0 08m K W for 6mm thick sheets WARNING Fire Risk Hearth pads must be installed exactly as specified High temperatures or hot embers may ignite concealed combustibles Fire Risk Comply with all minimum clearances to combustibles as specifie...

Страница 10: ...mbustibles G D E H C A I B REAR WALL F F J J G G L L K K MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in Millimeters Note A C and F Dimensions are to the center of the flue collar Explorer III AU Wood Appliance INSTALLATION 352 250 787 400 57 175 885 1179 310 DOUBLE WALL PIPE A B C D E F G H 729 1355 I J 1473 K L ...

Страница 11: ...uld Install through the warm space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind turbulence and down drafts Consider the appliance location in order to avoid floor and ceiling attic joists and rafters Locate termination cap away from trees adjacent stru...

Страница 12: ...e 3000mm 3000mm 3000mm or less more than 3000mm 600mm minimum NOTICE Chimney performance may vary Trees buildings roof lines and wind conditions affect performance Chimney height may need adjustment if smoking or overdraft occurs NOTICE Locating the appliance in a basement or in a location of considerable air movement can cause intermittent smoke spillage from appliance Do not locate appliance nea...

Страница 13: ...age 13 for termination height The option of outer casing slips to be taken into account 6 Flash the outer casing to the roof material with the appropriate approved flashing 7 If using an outer inner casing combination now install the inner casing ensuring it extends a minimum 200mm above the high side of the roof penetration If not using a combination see 11 below C Chimney Termination Requirement...

Страница 14: ...acket 5B as illustrated 6 Once the Flue Mounted Shield is fitted in position onto either of the two lower mounting brackets check to ensure a large gap is not present between the top of the wood fire and the base of the Flue Mounted Shield as this may result in a hot spot on the rear wall directly behind the flue outlet If your wood fire has a lift off top grill the Flue Mounted Shield should be r...

Страница 15: ...Freestanding 10 Triple Skin Instruction page QTY DESCRIPTION 4 6 Stainless Steel Inner Flue 915mm Long 1 7 3 4 Painted Perforated 915mm Long 1 7 3 4 Painted Perforated 915mm Long with in tabs 2 8 Galvanized Inner Flue Casing 915mm Long 1 10 Galvanized Notched Outer Flue Casing 915mm Long 1 10 Galvanized Outer Flue Casing 915mm Long 1 Cowl 1 Ceiling Ring 2 75 x 25 Angles 915mm Long 1 Installation G...

Страница 16: ...mum 25mm gap between flue pipe casing combustible material Non combustible material Hebel block or 12mm Promina board or similar under the flashing 25 25 Approved Flashing Roof Line Inner Casing 200mm above roof line Outer Casing Inner Casing 25 Internal Swage 25 25 12 5 Vented Ceiling Plate Flue Pipe C L C L Floor Protector as per AS NZS 2918 2001 Figure 16 1 ...

Страница 17: ...asing and 3 x ø flue distance of the ceiling plate ADD Cowl Casing Cover Spider Bracket Approved Flashing Ceiling Plate Batten A 3 x Ø flue pipe Ceiling flue pipe Ø ADD Cowl AS NZS2918 2001 Un tested flue with sloped ceiling penetration greater than 30 from horizontal A 25mm 4 6 3 b Fig 4 6 3 x ø flue from active flue to heat sensitive surface Casing Cover Spider Bracket Approved Flashing A Ceilin...

Страница 18: ...1 If that is the case you will need to order SRV7033 041 which includes a cover plate and sealing rope as shown in Figure 18 2 The goal is to seal the pedestal so no room air can leak into the pedestal or for cold air infiltration A Outside Air Kit Installation A source of air oxygen is necessary in order for combustion to take place Whatever combustion air is consumed by the fire must be replaced...

Страница 19: ...ZARDOUS CONDITIONS WHERE SUCH ACTION IS CONSIDERED THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTION CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE WARNING ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4013 WARNING DO NOT USE FLAMMABLE LIQUIDS OR...

Страница 20: ...20 7060 801A April 26 2019 Explorer III AU Wood Appliance 7 Reference Materials A Service and Maintenance Log Date of Service Performed By Description of Service ...

Страница 21: ...21 7060 801A April 26 2019 Explorer III AU Wood Appliance Date of Service Performed By Description of Service ...

Страница 22: ...22 7060 801A April 26 2019 Explorer III AU Wood Appliance Date of Service Performed By Description of Service ...

Страница 23: ... 0130 24 Y Screw Pan Head Philips 8 32 X 3 8 Pkg of 40 225 0500 40 Y Screw Sheet Metal 8 X 1 2 S Grip Pkg of 40 12460 40 Y Washer 1 4 Sae Pkg of 24 28758 24 Y Ending Manufacturing Date Active IMPORTANT THIS IS DATED INFORMATION Parts must be ordered from a dealer or distributor Hearth and Home Technologies does not sell directly to consumers Provide model number and serial number when requesting s...

Страница 24: ... and maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We recommend that you record the following pertinent information for your heating appliance Date purchased installed Serial Number Location on appliance Dealership purchased from Dealer Phone 1 Note...

Отзывы: