Explorer III AU Wood Appliance
Flex Line
Wire Tie
Wire Tie
Flex Adapter
Termination
Cap
For Floor Installa-
tions Remove
Circular “Knock-Out”
in Base of Pedestal.
Figure 18.2
Cover
Plate
Rope to Seal
Pedestal
Items Needed for Installation (not supplied)
-
102mm flex aluminum pipe, or if using alternate
material, then it shall be made from durable,
non-combustible, heat resistant material up to
350°F. Cut the pipe to the required length for
your installation.
- Phillips head screw driver
- Silicone sealant
- Drills and saws necessary for cutting holes through
the wall or flooring in your home.
1.
Remove all materials from packing box.
2.
Using a #2 Phillips screw driver attach the flex adapter
to the appliance using 4 screws
(Figure 18.1)
3.
For floor installations, remove circular” knock-out” in the
base of the pedestal.
4. Floor & Rear Installation:
Cut a 102mm hole in outside wall or floor to
accommodate outside air piping. Use 102mm
aluminum metal flex or rigid piping to directly connect
outside air to appliance intake. Use the supplied
termination cap with a rodent screen. Seal between
the wall (or floor) and the pipe with silicone to prevent
moisture penetration.
5. Floor Installation Alternative:
In some instances you may not be able to install the
flex pipe as show in
Figure 18.1
. If that is the case, you
will need to order SRV7033-041 which includes a cover
plate and sealing rope as shown in
Figure 18.2
. The
goal is to seal the pedestal so no room air can leak into
the pedestal or for cold air infiltration.
A. Outside Air Kit Installation
A source of air (oxygen) is necessary in order for
combustion to take place. Whatever combustion air is
consumed by the fire must be replaced. Air is replaced via
air leakage around windows and under doors. In homes
that have tightly sealed doors and windows, an outside air
source is needed. An optional Outside Air Kit is available.
Included in OAK-ACC:
Termination cap, (2) wire ties, flex adapter, and fasteners
Included in SRV7033-041:
Cover plate and sealing rope (see Floor Installation
Alternative below,
Figure 18.2
)
Figure 18.1 - Floor & Rear Installation
5
Appliance Set-Up
WARNING
Fire Risk. Asphyxiation Risk.
Do not draw outside combustion air from:
•
Wall, floor or ceiling cavity
• Enclosed space such as an attic
or garage
•
Close proximity to exhaust vents
or chimneys
Fumes or odor may result
WARNING
Asphyxiation Risk.
Outside air inlet must be located to prevent
blockage from:
• Leaves
• Snow or ice
•
Other debris
Block may cause combustion air starvation.
Smoke spillage may set off alarms or irritate
sensitive individuals.
Asphyxiation Risk.
Length of outside air supply duct shall NOT
exceed the length of the vertical height of the
exhaust flue.
•
Fire will not burn properly
• Smoke spillage occurs when door is
opened due to air starvation