What causes my glass to become dirty? 

If the glass has white ash build up it is normal and the glass should be cleaned. If it is a black soot build up airflow through 

the unit may be restricted. The most often cause is overdue maintenance and cleaning. See 

Maintaining and Servicing

 on 

page 18

 and/or make adjustments to the trim control.

How can I get more heat out of the appliance? 

The most often cause of diminished heat output is overdue maintenance and cleaning. See 

Maintaining and Servicing

 on 

page 18

.

What should I do if I smell smoke or there is ash/soot coming from the appliance? 

While there will always be some smoke smell from wood burning appliances (including pellet) you should investigate all 

venting to make sure it is sealed properly. Follow venting manufacturers recommendations for sealing pipe joints. 
In addition most homes are built very tight today and with exhaust systems can create negative pressure in the home. See 

Negative Pressure

 on 

page 15

 of the installation manual. For ash or soot check the above and the exhaust blower housing 

and seals.

Why would my appliance run fine last winter but not start this fall? 

It is possible that the stove was not properly prepared for the Non-burn season; see 

Troubleshooting Guide

 starting on 

page 23

.

Is there a place to lubricate the blowers to quiet them down? 

No. The most often cause of noisy blowers is from the impellers becoming dirty over time. See maintenance and service 

section for maintaining and servicing. 

What is the metal object with the bend in it that came inside the plastic bag? 

It is a clean-out tool used to help clean the fire pot and remove any jams in the rare event they occur in the feed tube. 

Why is there a black residue building up on the outside of my home? 

Wind can cause this to happen. If the appliance is oper ating correctly very little soot should ever exit the termina tion cap. 

Check to be sure the venting is installed per the owner’s manual and local codes.

Do I need an outside air kit? 

Outside air is required for mobile home installs and in some jurisdictions. Refer to 

Listing & Code Approvals

 on 

page 6

Mobile Home Installation

 on 

page 23

 of the installation manual and 

Appliance Set-up

 on 

page 20

 of the installation 

manual. Also refer to local building codes.

I am seeing sparks coming out of my pipe (termination cap) outside is this safe? 

This is normal. As long as clearances to combustibles were followed this is safe. 

I have no power to anything. Does this unit have a circuit breaker or fuse or a reset button? 

This appliance has one fuse on the control board and a resettable snap disc mounted to the feed tube. If the appliance 

overheats then the snap disc can be reset; if the fuse is blown the control board must be replaced.

Can I burn corn in my unit? 

Yes, this appliance can burn corn type fuel at a 1:1 ratio.

Where is the serial # located on my unit?

The serial number is located on the back of the stove.

No pellets are dropping in my fire pot. 

See 

Troubleshooting Guide

 starting on 

page 23

.

Contact your dealer for additional information regarding operation and troubleshooting. 

Visit 

www.quadrafire.com

 to locate a dealer. 

Содержание CASTILE-MBK-C

Страница 1: ...ls or authorities having jurisdiction about restrictions installation inspection and permits CAUTION If the information in these instructions is not followed exactly a fire could result causing proper...

Страница 2: ...stitue des Standards Nationaux Am rican ANSI et l Agence de Protection Environmental EPA Tested to ASTME E1509 04 and ULC S627 00 Room Heating Pellet Burning Type UM 84 HUD FOR USE ONLY WITH PELLETIZE...

Страница 3: ...mbustible Materials 8 C Combustible Materials 8 D Fuel Material and Fuel Storage 8 E Before Your First Fire 9 F Filling the Hopper 9 G General Operating Information 10 H Starting Your First Fire 10 I...

Страница 4: ...ots blowers junction boxes wire harnesses transformers and lights excluding light bulbs X X Molded Refractory Panels Glass Liners X Vent Free Burners Vent Free Logs X X Castings Medallions and Baffles...

Страница 5: ...overed by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted for a six year period to the original purchaser at catalyst WARRANTY...

Страница 6: ...ata collected during EPA emissions tests in accordance with the requirements of CSA B415 1 Weighted average HHV High Heating Value efficiency using data collected during EPA emissions tests in accorda...

Страница 7: ...eping room it is recommended that 3ft of vertical be installed prior to horizontally exiting the room and a smoke CO alarm be installed in the bedroom The size of the room must be at least 50ft per 1...

Страница 8: ...c Plywood OSB Sheet Rock drywall Any material that can ignite and burn flame proofed or not plastered or non plastered D Fuel Material and Fuel Storage Pellet fuel quality can greatly fluctuate This a...

Страница 9: ...rn into a hard glass like substance called a clinker when heated in the fire pot Trees from different areas will vary in mineral content That is why some fuels produce more clinkers than others Moistu...

Страница 10: ...he thermostat calls for heat your appliance will automatically light and deliver heat When the room is up to temperature and the thermostat is satisfied the red call light will go off and the applianc...

Страница 11: ...ol rod upward towards the symbol to increase the feed rate and flame height or down towards the symbol to decrease the feed rate and flame height 3 Re tighten the wing nut I Fire Characteristics A pro...

Страница 12: ...tup sequence Restarting After a Power Failure 1 For an electrical disruption the appliance will start on its own providing the control system is asking for heat NOTICE Clearances may only be reduced b...

Страница 13: ...his setting there are no program routines for the thermostat to follow and the temperature control will be set only by the UP and DOWN buttons on the front panel ITEM 04 PERD EVENT OR PERIOD QUANTITY...

Страница 14: ...t to 4 P Thermostat Operation Instructions SET DAY AND TIME Place the Set switch into the DAY TIME position With the day flashing press UP or DOWN to set the day or the week Press NEXT and the clock t...

Страница 15: ...TEMPERATURE switch to OFF 2 Move SET switch to RUN 3 Press and hold both UP and DOWN buttons together for at least 5 seconds the words SET and CAL will appear on the display along with a single flash...

Страница 16: ...the thermostat housing Figure 16 1 Figure 16 2 Full battery icon Figure 16 3 Low battery icon Figure 16 1 CONNECT THERMOSTAT WIRES TO APPLIANCE There is a 4 screw terminal block located on the back l...

Страница 17: ...ice section for maintaining and servicing What is the metal object with the bend in it that came inside the plastic bag It is a clean out tool used to help clean the fire pot and remove any jams in th...

Страница 18: ...el OR X Hopper Every 1 ton of fuel or when changing fuel types OR X Venting System More frequently depending on the fuel type OR X Follow the detailed instructions found in this section for each step...

Страница 19: ...the 2 open holes A paint brush works well for this Close slide plates d This ash is deposited in the same ash drawer as the fire pot debris The ash drawer should be emptied every time you clean the fi...

Страница 20: ...n the back of the baffle This will require removing the baffle Refer to Baffle on page 27 6 Cleaning Heat Exchanger Chambers Drop Tube Frequency Monthly or every 1 ton of fuel By Homeowner The amount...

Страница 21: ...has been unplugged and the exhaust blower is off The products of combustion will contain small particles of fly ash The fly ash will collect in the exhaust venting system and restrict the flow of the...

Страница 22: ...y circumstances re enter the building E High Ash Fuel Content Maintenance Frequency As needed By Homeowner Poor quality pellet fuel or lack of maintenance can create conditions that make the fire pot...

Страница 23: ...pellets in fire pot Fire pot clean out plate not closed Check that fire pot clean out plate is fully closed Fire pot is dirty The ignition hole between the igniter bracket and fire pot is blocked Clea...

Страница 24: ...o start or does not shut off Blower not plugged in Check that blower is plugged into wire harness Blower is clogged with ash Clean exhaust system Blower is defective Replace blower Control box is defe...

Страница 25: ...and slide towards you Figure 25 3 e Remove the left side panel by loosening 2 screws do not remove and pull side panel away Unplug the 2 black blower wires by disconnecting the spade connectors f To...

Страница 26: ...et appliance cool completely if running Then unplug appliance before servicing Disconnect appliance from venting at the rear of appliance 2 Remove both upper and lower side curtains by removing the si...

Страница 27: ...for left brick 3 Reinstall bricks in reverse order ensuring that the bricks are flush against the back wall of the firebox Figure 27 4 and Figure 27 5 Figure 27 1 Brick is flush against back wall Bric...

Страница 28: ...down unplug it and remove the ash drawer 2 The wire leads to the igniter are connected to the wire harness with 1 4 inch male female spade connectors Disconnect the spade connections and remove the ig...

Страница 29: ...he function of the red call light is to indicate that the thermostat is calling for heat 14 Reset Button The reset button is located on the back of the appliance in the upper right corner below the he...

Страница 30: ...ated on the right side of the appliance on the bottom of the heat exchanger box There are 2 purple wires connected to it This snap disc turns the convection blower on and off as needed Power is always...

Страница 31: ...Reset Button Reset Button Combustion Blower Figure 31 3 TERMINAL BLOCK CENTER 2 SCREWS FOR THERMOSTAT WIRES POWER OUTLET FUSE Fuse Red Call Light is located on top of Junction Box behind the Control...

Страница 32: ...32 02 23 7021 802K C Service and Maintenance Log Date of Service Performed By Description of Service...

Страница 33: ...33 02 23 7021 802K Date of Service Performed By Description of Service...

Страница 34: ...nufacturing Date April 2019 Ending Manufacturing Date Active Castile Pellet Freestanding Stove CASTILE TWL C CASTILE MBK C CASTILE PMH C Part number list on following pages 02 23 1 2 3 4 5 6 7 8 9 10...

Страница 35: ...e Assembly SRV7001 034 Y 7 Outer Skin Left SRV7021 119 8 Brick Left Right Cast SRV414 0270 9 Brick Center Cast SRV414 0260 10 Cast Retainer Lower Left Assembly SRV7021 018 11 1 Pull Rod Assembly SRV70...

Страница 36: ...y color Black 413 0030BK Mahogany 413 0030PMH Twilight 413 0030TWL 15 Door Assembly SRV7021 031 15 1 Hinge Female SRV450 2910 Y 15 2 Glass Assembly SRV7021 032 Y 15 3 3 4 Inch Rope Gasket 50 Ft SRV240...

Страница 37: ...e Black SRV7021 125MBK Mahogany SRV7021 125PMH Twilight SRV7021 125TWL 22 Convection Plenum Back SRV7021 120 23 Outer Skin Right SRV7021 118 24 Vacuum Switch SRV7000 531 Y 25 Control Board 3 Speed SRV...

Страница 38: ...ny 1 00 0014 Twlight 0001285 Power Cord 3 20 51578 Y Deflector Bottom Airwash SRV413 0680 Feed Adjustment Plate SRV7001 182 Fuse 7 Amp Junction Box Pkg of 10 812 0380 10 Y Fuse 8 Amp Control Box Pkg o...

Страница 39: ...0 143 Collar Offset Top Vent 812 3570 Damper 3 Inch Tall Vertical Installs Only PEL DAMP3 Y Damper 4 Inch Tall Vertical Installs Only PEL DAMP4 Outside Air Kit Rear 811 0872 Channel Air Intake SRV413...

Страница 40: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...

Отзывы: