Quadra-Fire 57ST-ACC-C Скачать руководство пользователя страница 2

 

      7038-227C 

   

August 

13, 

2018

57ST-ACC-C

CONFIDENTIAL PROPERTY OF HEARTH & HOME TECHNOLOGIES INC.

PART NAME:

DRAWN BY:

SCALE:

MATERIAL:

SHEET:

PART NUMBER:

REV:

THIS PRINT IS CHECKED AND CONTROLLED BY THE ENGINEERING 

DEPARTMENTS OF HEARTH & HOME TECHNOLOGIES INC.

ECO #

DATE

BY

REV

UNLESS OTHERWISE SPECIFIED DIMS ARE INCHES[MM] & : TOLERANCES ARE:  (2) PLACE DEC : ± 0.03     (3) PLACE DEC: ± 0.005     ANGLE: ± 2°     FRACTION: ± 1/16

OUTSIDE MATERIAL.

NORMAL DIM & INSIDE MATERIAL.

OUTSIDE APEX

INSIDE APEX  -  DIMS ENCLOSED BY AN OVAL ARE CRITICAL DIMENSIONS

REVISIONS

ITEM

PART NUMBER

PART NAME

QTY

1

7038-228

SERIAL RATING PLATE

8.50

INSTALLATION: FULL VERTICAL      INSTALLATION: ENTIÈREMENT VERTICALE 

 

A B C D E F G H

 

SINGLE WALL PIPE 

15.75 (400) 9 (229)  25.5 (648)  12 (305)  4 (102) 16.875 (429)   49 (1245)  N/A 

CONDUIT DU MUR SIMPLE

DOUBLE WALL PIPE  13.75 (349) 7 (178)  25.5 (648)  12 (305)  1 (25)  13.875 (352)   49 (1245)  N/A 

DOUBLE MUR DE TUYAUX

INSTALLATION: HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP

INSTALLATION: HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE

SINGLE WALL PIPE 

16.75 (425)  10 (254)  25.5 (648)  12 (305)  4 (102) 16.875 (429)   49 (1245)   18 (457) 

CONDUIT DU MUR SIMPLE

DOUBLE WALL PIPE  13.75 (349)     7 (178) 25.5 (648)   12 (305)  1 (25) 13.875 (352)    49 (1245)   12 (305) 

DOUBLE MUR DE TUYAUX

INSTALLATION:  90° ELBOW OFF TOP OF STOVE THROUGH BACKWALL

INSTALLATION:  90° DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIERE

SINGLE WALL PIPE 

16.75 (425) 10 (254)  25.5 (648)  12 (305)  4 (102)  16.875 (429)    49 (1245)  18 (457) 

CONDUIT DU MUR SIMPLE

INSTALLATION: ALCOVE - Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 

HT** listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) 

Maximum depth of Alcove shall be no more than 48 inches (1219mm) and the referenced alcove clearances.
INSTALLATION: ALCÔVE - Six pouces (6 pouces) (152mm) de diamètre listé air isolé tuyau de raccordement à double paroi 

avec UL103 HT ** cotée Classe usine construite "A" cheminée ou une cheminée de maçonnerie. (Mobile Home doit être équipé 

d' un pare-étincelles.) Profondeur maximale de Alcove ne doit pas être plus de 48 pouces (1219mm) et les dégagements en 

alcôve référencés. 

(**In Canada must comply with Standard CAN/ULC-S629-M87 for the 650°C Factory-built chimney.)

(**Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650°C cheminée bâtit en usine.)
DOUBLE WALL PIPE      13.75 (349)    7 (178)  25.5 (648)  12 (305)  N/A 

N/A 

49 (1245)       N/A 

DOUBLE MUR DE TUYAUX

SPÉCIFICATIONS DE LA VENTILATION:

MUR SIMPLE:

 De six (6 inches) (152mm) de diamètre le connecteur de conduit de minimum 

d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en usine UL103HT* de 
Classe "A", adéquate pour usage avec les combustions solides, ou une cheminée de briques, 
avec espaces libres référés.

MUR DOUBLE:

 De six (6 inches) (152mm) de diamètre, le connecteur du conduit d'air isolé 

pour mur double avec une cheminée bâtit en usine UL103HT* de Classe "A:, ou une cheminée 
de briques, avec espaces libres alloués.

MAISON MOBILE:

 Utiliser un conduit de mur double par Dura-Vent DVL, Selkirk Metalbestos 

DS ou Security DL. Doit être équipé d'un arrêt d'étincelle. Utiliser les espaces libres pour mur 
double comme mentionné ci-bas.

ESPACES LIBRES MIN DES MATÉRIAUX COMBUSTIBLES: En Pouces & (millimètres)

NOTE:  Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de 

l'entrée du conduit

LISTED ROOM HEATER, SOLID FUEL TYPE.   ALSO 

FOR USE IN MOBILE HOMES (US ONLY).  (UM) 

84-HUD .

  "For Use with Solid Wood Fuel Only" 

352 Mountain House Road, Halifax, PA 17032

www.quadrafire.com

CAUTION

:

 

                              

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2020 particulate emission standards using crib wood at 1.8 G/HR 

EPA Method 28R, ASTM 2515-11 and CSA B415.1-10. 

This wood heater needs periodic inspection and repair for proper operation. Consult the 

owner’s manual for further information. 

It is against federal regulations to operate this wood heater in a manner inconsistent with 

the operating instructions in the owner’s manual

PREVENT HOUSE FIRES

Install and use only in accordance with manufacturer's installation 

and operating instructions. Contact local building or fire officials 

about restrictions and installation inspections in your area. Do not 

obstruct the space beneath heater.

For use only with leg and pedestal options intended for this model, 

refer to owner’s manual for appropriate part numbers and 

installation instructions.

SUITABLE FOR MOBILE HOME INSTALLATION

WARNING - For Mobile Homes:  Do not install in a sleeping room.  

An outside combustion air inlet must be provided and unrestricted 

while unit is in use.  The structural integrity of the mobile home 

floor, ceiling and walls must be maintained.  The stove needs to be 

properly grounded to the frame of the mobile home.  Components 

required for mobile home installation:  Outside Air Kit, Part Number 

OAK-ACC.

Refer to manufacturer's instructions and local codes for 

precautions required for passing chimney through a combustible 

wall or ceiling and maximum offsets.

Inspect and clean chimney frequently - Under Certain Conditions of 

Use, Creosote Buildup May Occur Rapidly.

Do not connect this unit to a chimney serving another appliance.

Optional Components:

 Optional Blower, Part BKST-350.

Electrical Rating:

  115 VAC, 1.2 Amps, 60 Hz.

Route power cord away from unit.  Do not route cord under or in 

front of appliance.

DANGER:

 Risk of electrical shock. Disconnect power supply 

before servicing.

Replace glass only with 5mm ceramic available from your dealer.

Do not use grate or elevate fire.  Build wood fire directly on hearth.

Do not overfire - if heater or chimney connector glows, you are 

overfiring.

OPERATE ONLY WITH DOORS CLOSED

Open only to add fuel to the fire.

Do NOT operate before fully assembling components.

WARNING:

 Only used approved wood fuel listed in owners manual. 

Burning any other fuel will void warranty.

   

FLOOR PROTECTION:

Floor protector must be Type I Hearth Pad

 non-combu

stible 

material or equivalent, extending beneath heater and to 

front/sides/rear as indicated on the diagram below. Exception: 

Non-combustible floor protections must extend beneath the 

flue pipe when installed with horizontal venting and extend 2 

inches (51mm) beyond each side.  

Safety and Emissions

Respectively

Report #0061WS092S

Report #0061WS092E

HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS.  KEEP 

FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS

VENT SPECIFICATIONS:

SINGLE WALL:

 Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or 

blued steel connector pipe, with a listed factory-built UL103HT* Class "A" chimney, 
suitable for use with solid fuels, or a masonry chimney, and the referenced 
clearances.

DOUBLE WALL:

  Six inch (6 inches) (152mm) diameter, listed double wall air 

insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, or  
a masonry chimney and the referenced clearances

MOBILE HOME:

 Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos 

DS or Security DL double wall connector pipe. Must be equipped with a spark 
arrestor.  Apply double wall clearances below when installing unit.

MIN CLEARANCES TO COMBUSTIBLE MATERIALS: Inches & (Millimeters)

NOTE:  All "A" , "C" and "F" Dimensions are to inside diameter of flue 

collar.

TESTED TO:

/ TESTÉ À:

   UL 1482-11 (R2015),  ULC S627-00

R

7038-228_R2

CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT 

PEUT CAUSER DES BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR 

L'ÉTIQUETTE ET LES INSTRUCTIONS.

ATTENTION:

APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE 

COMBUSTIBLE SOLIDE, "Pour Usage Avec Bois Solide Seulement"

PRÉVENTION DES FEUX DE MAISON

Installez et utilisez en accord avec les instructions d'installation 

et d'opération du fabricant. Contactez le bureau de la 

construction ou le bureau des incendies au sujet des restrictions 

et des inspections d'installation dans votre voisinage. Ne pas 

obstruez l'espace en dessous de l'appareil.

Référez vous aux instructions du fabricant et des codes locaux 

pour les précautions requises pour passer une cheminée à 

travers un mur ou un plafond combustibles, et les 

compensations maximums.

Inspectez et nettoyez la cheminée fréquemment. Sous 

certaines conditions, il se peut que la créosote s'accumule 

rapidement.

Ne pas connecter cet appareil à une cheminée servant un autre 

appareil.

Composants Optionnels: Ventilateur Optionnel, Pièce 

BKST-350.

Puissance Électrique:

 115 VAC, 1.2 Amps, 60 Hz.

Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil 

électrique au dessus ou en dessous de l'appareil.

DANGER:

 Il y a risque de décharge électrique.  Déconnectez le 

fil électrique de la prise de contact avant le service.

Remplacez la vitre seulement avec une vitre céramique de 5 

mm disponible chez votre fournisseur.

N'élevez pas le feu. Bâtissez le feu de bois directement sur 

l'âtre.

Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau de 

cheminée rougissent, vous surchauffez.

Opérez l'appareil seulement lorsque la porte de chargement est 

fermée. Ouvrez la porte seulement lorsque vous devez ajouter 

des combustibles dans le feu.

Ne mettez PAS le poêle en marche tant que tous les composants 

n’ont pas été entièrement assemblés.

ATTENTION:

 Seulement utilisé carburant approuvé indiquée 

dans le manuel des propriétaires. La combustion d'autres 

combustibles annulera la garantie.

PROTECTION DU PLANCHER:

Le protecteur de plancher doit être du matériau incombustible 

type I Hearth Pad ou équivalent, s'étendant sous le radiateur et à 

l'avant / côté / arrière comme indiqué sur le schéma ci-dessous. 

Exception: les protections de sol incombustibles doivent 

s'étendre sous le conduit de fumée lorsqu'elles sont installées 

avec une ventilation horizontale et s'étendent à 2 pouces (51 

mm) au-delà de chaque côté.  

2017   2018   2019 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE

BACKWALL/SIDE

WALL/

MUR 

ARRIÈRE/MUR 

DE CÔTÉ 

CORNER 

INSTALLATION/

INSTALLATION 

DU COIN 

E

F

E

F

90  OFF TOP UP & OUT 

CEILING CLEARANCE/

ESPACE LIBRE DU 

DESSUS DE 

L'APPAREIL AU 

PLAFOND AVEC 90  DE 

COURBURE 

G

H

ALCOVE TOP 

VIEW /

VUE DU HAUT DE 

L'ALCÔVE 

C

D

ALCOVE SIDE 

VIEW / 

VUE DE CÔTÉ 

DE L'ALCÔVE

G

A

Manufactured by:
Fabriqué par:

O-T  L

Tested and 

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

5700 Step Top ACC-C

STOVE TO CEILING CLEARANCE/
ESPACE LIBRE DU POÊLE AU PLAFOND 

Made in U.S.A. of US and 

imported parts.

Fabriqué aux États-Unis-d’Amérique par 

des pièces d’origine américaine et pièces 

importées.

Serial No. / N° de série

HF

BARCODE LABEL

A

B

C

D

CANADA

203mm (8")

203mm

(8")

457mm (18")

1394mm 

(54-7/8")

minimum

1092mm (43")min

203mm

(8")

16" from glass

8"

USA

Fuel loading door

33-1/2”

minimum

45-7/8”

minimum

Serial No.

Model 

Name

Test Lab & 

Report No.

Mfg. Date

S A

M P

L E

A. Sample of Serial Number / Safety Label 

LOCATION:  Back of appliance

NOTE:

 Clearances may only be reduced by means approved 

by the regulatory authority having jurisdiction

Содержание 57ST-ACC-C

Страница 1: ... over fire and generate poisonous gases i e carbon monoxide WARNING If the information in these instructions is not followed exactly a fire could result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over fi...

Страница 2: ...with 5mm ceramic available from your dealer Do not use grate or elevate fire Build wood fire directly on hearth Do not overfire if heater or chimney connector glows you are overfiring OPERATE ONLY WITH DOORS CLOSED Open only to add fuel to the fire Do NOT operate before fully assembling components WARNING Only used approved wood fuel listed in owners manual Burning any other fuel will void warrant...

Страница 3: ...rence Maintenance Guide 18 B Cleaning and Operating the Ash Removal System 19 C General Maintenance 19 4 Troubleshooting Guide 21 5 Service Part Replacement 22 A Glass Replacement Door Assembly 22 B Firebrick Replacement 22 C Snap Disc Replacement 22 D Door Handle Assembly 23 E Baffle Removal 23 F Tube Channel Assembly Replacement 24 6 Reference Materials 25 A Service Maintenance Log 25 B Exploded...

Страница 4: ...d glass X X X Factory installed blowers X Molded refractory panels X Ignition Modules X Firepots burnpots mechanical feeders auger assemblies X Vent Free burners Vent Free ceramic fiber logs Aluminized Burners X X Castings and Baffles 6 years 3 years X Catalyst limitations listed 7 years 3 years X X Manifold tubes HHT chimney and termination 10 years 1 year X Burners logs and refractory Limited Li...

Страница 5: ...ging a warranty call Travel and shipping charges for parts are not covered by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted for a six year period as follows if the original o From 37 to 72 months a pro rated credit will be allowed against a replacement catalyst and labor credit necessary to install Amount of Time Since Purc...

Страница 6: ... water or weather damage which is the result of but not limited LIMITATIONS OF LIABILITY have other rights which vary from state to state EXCEPT TO THE EXTENT PROVIDED BY LAW HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE ...

Страница 7: ...nd after refueling to prevent Spillage of smoke flame and carbon monoxide Spillage of sparks coals and logs Over firing DO NOT leave the appliance unattended with the door open Starting a fire may not require an open door for draft The air control should supply adequate draft ADD MORE WOOD REDUCE AIR CONTROLS Ser to desired heat output The appliance is ready for normal operation HIGH BURN RATE CON...

Страница 8: ...and data collected during EPA emission test A range of BTU outputs based on HHV and the burn rates from the low and high EPA tests using Douglas Fir dimensional lumber A peak BTU out of the appliance calculated using the maximum first hour burn rate from the High EPA Test and the BTU content of cord wood 8600 times the efficiency This wood appliance needs periodic inspection and repair for proper ...

Страница 9: ... walls must be maintained The appliance must be properly grounded to the frame of the mobile home with 8 copper ground wire and chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm diameter liner must be used Outside Air Kit part OAK ACC must be installed in a mobile home installation Improper installation adjustment alteration service or maintenance can cause injury o...

Страница 10: ...from the center it is dry If your wood sizzles in the fire even though the surface is dry it may not be fully cured Splitting wood before it is stored reduces drying time Wood should be stacked so that both ends of each piece are exposed to air since more drying occurs through the cut ends than the sides This is true even with wood that has been split Store wood under cover such as in a shed or co...

Страница 11: ...ED LOW Burn Rate Air Control Start Up Air Control Manual Timer ACC Shut Down Pull Forward to Shut Down Injury Risk Gloves recommended CAUTION D Air Controls Users will need to find their preferred setting between high and low based on desired heat output installation configuration and fuel type 1 Burn Rate Air Control This air supply enters at the upper front of the firebox near the top of the gla...

Страница 12: ... pushing the knob all the back toward the appliance to HI then pull forwards towards the front of the appliance until the knob stops At that point move the Burn Rate Air Control spring handle to 1 8 1 2 from the low setting 3 Medium high burn setting Burn Rate Air Control spring handle up to high position Then activate the ACC timer system by pushing the knob all the back toward the appliance to H...

Страница 13: ...liance Be sure the room is adequately ventilated and the flue unobstructed 5 Light the paper in the appliance NEVER light or rekindle fire with kerosene gasoline or charcoal lighter fluid the results can be fatal 6 Once the kindling is burning quickly add several full length logs 3 inches 76mm or 4 inches 102mm in diameter Be careful not to smother the fire Stack the pieces of wood carefully near ...

Страница 14: ... in contact with the back of the firebox and even with each other in the front Ceramic Blanket Back of Firebox Baffle Board Baffle Retainer Bracket The baffle boards are FRAGILE Use extreme caution when loading firewood to prevent Cracking breaking or damaging the baffle boards DO NOT operate the appliance without baffle boards CAUTION WARNING Fire Risk Firebox damage due to improper baffle placem...

Страница 15: ...urn material other than wood May result in illness or possible death J Opacity Smoke This is the measure of how cleanly your appliance is burning Opacity is measured in percent 100 opacity is when an object is totally obscured by the smoke column from a chimney and 0 opacity means that no smoke column can be seen As you become familiar with your appliance you should periodically check the opacity ...

Страница 16: ...ust equipment Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting should be a sealed can design Attic hatches weather stripped or sealed Attic mounted duct work and air handler joints and seams taped or sealed K Clear Space Do NOT place combustible o...

Страница 17: ...ncreased CONTACT YOUR DEALER for additional information regarding operation and troubleshooting Visit www quadrafire com to find a dealer M Frequently Asked Questions Fire Risk Keep combustible materials gasoline and other flammable vapors and liquids clear of appliance Do NOT store flammable materials in the appliance s vicinity DO NOT USE GASOLINE LANTERN FUEL KEROSENE CHARCOAL LIGHTER FLUID OR ...

Страница 18: ...g the burn season or more frequency if chimney exceeds or is under 14 16 ft 4 3m 4 8m measured from bottom of appliance This will prevent pipe blockage poor draft and chimney fires Always burn dry wood to help prevent cap blockage and creosote build up Firebrick Ash Removal WEEKLY or After Every 25 Loads of Wood Ashes must be cool before you can dispose of the ashes in a non combustible container ...

Страница 19: ...ed in your owner s manual Figure 19 2 Access Cover Handle Insert Access Cover Handle handle into slot of ARS Cover to remove ARS Cover for cleaning ash out of firebox Fire Risk Make sure Ash Removal System door is sealed tight against the gasket Air leakage may cause Over fire condition Flame and or smoke spillage Wood to burn too fast Do NOT use Ash Removal System while stove is burning WARNING I...

Страница 20: ... first time If not cleaned properly before lighting your first fire the oils can cause permanent markings on the plating After the plating is cured the oils will not affect the finish and little maintenance is required Wipe clean as needed 3 Disposal of Ashes Frequency When ash is within 1 3 4 in 44mm of firebox lip By Homeowner Ashes should be placed in a metal container with a tight fitting lid ...

Страница 21: ...for adequate vent height refer to Chimney Height Section Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Seasoned Wood Section Bed of coals not established before adding wood Start with paper kindling to establish bed of coals refer to Building a Fire Section Flue blockage such as birds nests or leaves in termination cap Have chim...

Страница 22: ...sh with the side of the appliance A Glass Replacement Door Assembly Replace with 5mm ceramic glass only 1 Ensure that the fire is out and the appliance is cool to the touch 2 Protect a table or counter top with padding or towels Protect your hands and wear gloves to prevent injury 3 Remove the door with the broken glass by lifting the door up and off of the hinges 4 Lay door face down on a table o...

Страница 23: ... container 2 The baffle board has 2 pieces With the ceramic blanket still in place slide one baffle piece over the top of other one and pull out top piece through the door opening and then remove bottom baffle piece Figure 23 2 3 Remove the ceramic blanket 4 Re install the baffle pieces one piece at a time Be sure the baffle boards are even with the front manifold tube and is resting on all tubes ...

Страница 24: ...eces and right hand rear brick 5 Remove the 2 brick retainers by sliding back and then up 6 Remove the baffle protection channel by rolling forward and out of the firebox 7 Remove three bolts from inside fire box NOTE Soak the bolts with penetrating oil for at least 15 minutes before trying to remove them Replacing Tube Channel Assembly 8 Slide the tube channel assembly to the left Drop the right ...

Страница 25: ...August 13 2018 7038 227C 25 57ST ACC C 6 Reference Materials A Service Maintenance Log Date of Service Performed By Description of Service ...

Страница 26: ...26 7038 227C August 13 2018 57ST ACC C Date of Service Performed By Description of Service ...

Страница 27: ...August 13 2018 7038 227C 27 57ST ACC C Date of Service Performed By Description of Service ...

Страница 28: ...R 57ST ACC C Beginning Manufacturing Date Sept 2017 Ending Manufacturing Date Active Step Top Wood Stove Advanced Combustion Control Part number list on following page 08 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 20 21 22 23 24 25 18 B Exploded View ...

Страница 29: ...mbly SRV7038 008 Y 12 Secondary Tube Gasket SRV7038 187 13 Door Assembly Black DR 57BK FH Nickel Trim DR 57NL FH 14 Hinge Pins 1 2 Qty 2 Black 7000 606 2 Qty 2 Gold 832 0250 Qty 2 Nickel SRV430 5320 15 Glass Assembly SRV7000 014 Y Glass Frame Set GLA FRM 5700 Gasket Glass Tape 3 4 Field Cut to Size 5 Ft 832 0460 Y Rope Door 3 4 x 84 Field Cut to Size 7 Ft 832 1680 Y Logo Quadra Fire Pkg of 10 7000...

Страница 30: ... 1 25 Qty 13 Req 18 2 Brick 9 x 1 75 x 1 25 Qty 3 Req 18 3 Brick 7 x 1 75 x 1 25 Qty 1 Req 18 4 Brick 5 x 4 50 x 1 25 Qty 2 Req 18 5 Brick 7 x 4 5 x 1 25 Qty 4 Req 18 6 Brick 6 x 4 5 x 1 25 Qty 4 Req 18 7 Brick 6 x 1 75 x 1 25 Qty 1 Req Brick Uncut Qty 1 832 0550 Qty 6 832 3040 19 Brick Retainer Rear SRV7038 148 20 Leg Adapter Set Bracket Left Right 7038 029 21 Panel Assembly Side Right SRV7038 00...

Страница 31: ...e 7033 210 25 5 Latch Magnet SRV229 0631 25 6 Control Arm Assembly Rear SRV7038 004 25 7 Timer Door Control Arm Assembly SRV7038 062 Door Gasket 7033 282 Y 25 8 Timer Only Replacement Assembly SRV480 1940 Y 25 9 Timer Arm Assembly 7033 034 Y 26 1 ARS Access Cover SRV7038 196 26 2 Handle Acces Cover SRV7038 197 26 3 Channel Ash Removal System SRV7033 172 26 4 ARS Gasket SRV7033 296 26 5 ARS Assembl...

Страница 32: ...74 27 7 Ash Pan Assembly 7033 008 Ash Pan Leg ARS 7033 050 Component Pack Leg Step Top Includes Gasket For Ash Removal Fasteners 7037 036 27 8 Legs Queen Anne Qty 4 831 1240 Qty 4 LEGS QANL 27 9 Leg Adapter Set Bracket Left Right SRV7038 028 Leg Kit Ash Removal System ARS Black LEG KIT BK Nickel LEG KIT NL Component Pack Includes Touch Up Paint Owners Manual Warranty Card Access Cover Handle SRV70...

Страница 33: ...1 Convection Blower SRV230 0470 Y Wire Harness 7033 262 Wire Harness Blower AC SRV7000 073 Y Outside Air Kit Floor Rear OAK ACC Outside Air Collar Assembly 7033 039 Outside Air Shield SRV33271 Y FASTENERS Avk Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Bolt Hex Head 1 4 20x1 Pkg of 10 25221A 10 Y Button Head 1 4 20x0 5 Pkg of 20 32328 20 Y Nut Keps Lock 10 32 Pkg of 40 226 0050 40...

Страница 34: ...e purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dealership purchased from ________________________________________ Dealer phone _1 _____ _____ ______ Notes ________________________________________________________________________________________ ______...