After activating the timer (ACC), if the control is placed
within the rear air section on the label it will allow rear air
to enter the firebox. This will not interfere with the timer
gradually closing the front air channel in 25 minutes. If
control is set on “HI” it over-rides the timer (ACC).
F. Burn Rates and Operating Efficiency
For maximum operating efficiency
This wood appliance has a manufacturer-set minimum
low burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this
wood appliance in a manner inconsistent with operating
instructions in this manual.
•
Burn dry, well-seasoned wood.
Burn Rates
1. Low burn setting:
•
Burn Rate Air Control spring handle up to high
position for 5 minutes.
• Then activate the ACC timer system by pushing the
knob all the back toward the appliance to “HI” then
pull forwards towards the front of the appliance
until the knob stops
(Figure 9.1 on page 9)
.
•
At that point close the Burn Rate Air Control by
moving the spring handle to the low setting.
2. Medium low burn setting:
•
Burn Rate Air Control spring handle up to high
position for 5 minutes.
• Then activate the ACC timer system by pushing the
knob all the back toward the appliance to “HI” then
pull forwards towards the front of the appliance
until the knob stops.
•
At that point move the Burn Rate Air Control spring
handle to 1/8”-1/2” from the low setting.
3. Medium high burn setting:
•
Burn Rate Air Control spring handle up to high
position.
• Then activate the ACC timer system by pushing the
knob all the back toward the appliance to “HI” then
pull forwards towards the front of the appliance
until the knob stops.
•
At that point move the Burn Rate Air Control spring
handle to 1/2” – high.
4. High burn setting:
•
Burn Rate Air Control spring handle up to high
position
•
Also activate ACC timer system knob pushed back
to the “HI” position.
NOTE:
The above information is provided as a guideline
only. Altitude and other circumstances may
require control adjustments to achieve the
desired burn rates.
NOTE:
Operate appliance on High Burn 45 minutes a day
to help keep flue/chimney clean.
WARNING
Risk of Fire.
When set on High Burn Rate and over-riding the
Automatic Combustion Control system an over fire
situation can occur and may result in a chimney
fire.
Over firing will void the appliance warranty.
NOTE:
If using the optional blower use burn settings 1-3
burn settings the blower shall be off for the first 30
minutes and then be operated in the high position
at 30 minutes. For high burn setting, blower may
continue to be on full after the loading of the fuel.