background image

13

08/23

7038-227L

F. Blower Operating Instructions

G. Opacity (Smoke)

This is the measure of how cleanly your appliance is burning. 

Opacity is measured in percent; 100% opacity is when an 

object  is  totally  obscured  by  the  smoke  column  from  a 

chimney, and 0% opacity means that no smoke column can 

be seen. As you become familiar with your appliance, you 

should periodically check the opacity. This will allow you to 

know how to burn as nearly smoke-free as possible (goal of 

0% opacity).

Figure 13.2 

MANUAL

FAN

AUTO

LOW

HIGH

OFF

MANUAL: 

Over-rides 

the Snap 

Disc

AUTO: Fan 

will turn 

ON/OFF 

Automatically 

by the Snap 

Disc

Controls 

the Fan 

Speed

NOTE:

 If your Quadra-Fire wood appliance is equipped 

with  an  optional  blower,  you  should  follow  these 

guidelines:

1. 

Initial (cold) start-up and all Burn Settings: 

The 

blower can be plugged in and turned on right away. The 

blower fan is turned on and off by a snap disc. When your 

appliance has reached a certain temperature the blower 

will turn on and when your appliance has cooled down 

to a certain temperature it will turn off. Switch on blower 

control must be set to auto for this feature to work.

2.  The  blower  is  equipped  with  a  speed  control.  Adjust 

the fan speed by turning the speed control clockwise to 

“Low” or counterclockwise to “High”.

3. 

Snap Disc Location: 

If you find the blower coming on 

and off at undesirable temperatures, relocate the snap 

disc to another location in the designated zone on the 

back of the appliance (

Figure 13.1).

 There is a manual 

over-ride switch to deactivate the snap disc, if necessary 

(Figure 13.2)

.

Figure 13.1 

Snap Disc 

Bracket 

with 

Magnet

Fire Risk.

• DO NOT BURN GARBAGE OR 

FLAMMABLE FLUIDS SUCH AS 

GASOLINE, NAPHTHA OR ENGINE OIL.

•  Do NOT burn treated wood or wood with 

salt (driftwood).

•  May  generate  carbon  monoxide  if  burn 

material other than wood.

May result in illness or possible death.

WARNING

When  burning  your  first  fire,  you  will  experience 

smoke and odor from the appliance resulting from the 

curing  of  paint  and  burning  off  of  any  oils  remaining 

from manufacturing.

OPEN WINDOWS DURING INITIAL BURN TO 

DISSIPATE SMOKE AND ODORS!

•  Odors may be irritating to sensitive individuals.

•  Smoke detectors may activate.

CAUTION

WARNING

Fire Risk.

Keep  combustible  materials,  gasoline  and 

other  flammable  vapors  and  liquids  clear 

of appliance.

•  Do NOT store flammable materials in the 

appliance’s vicinity.

• DO NOT USE GASOLINE, LANTERN FUEL, 

KEROSENE, CHARCOAL LIGHTER FLUID OR 

SIMILAR LIQUIDS TO START OR “FRESHEN UP” A 

FIRE IN THIS Appliance.

•  Keep all such liquids well away from the appliance 

while it is in use.

•  Combustible materials may ignite.

Содержание 5700

Страница 1: ...s appliance Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials...

Страница 2: ...icing Replace glass only with 5mm ceramic available from your dealer Do not use grate or elevate fire Build wood fire directly on hearth Do not overfire if heater or chimney connector glows you are ov...

Страница 3: ...y Specifications 7 D Glass Specifications 8 E Mobile Home Approved USA only 8 F Sleeping Room 8 G California Prop65 8 2 Operating Instructions A Over Firing Your Appliance 9 B Wood Selection Storage 9...

Страница 4: ...ccupancy date The term Lifetime in the table below is defined as 20 years from the beginning date of warranty coverage for gas appliances 10 years from the beginning date of warranty coverage for wood...

Страница 5: ...r forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not supplied with the applicable Product or any o...

Страница 6: ...D KINDLING LIGHT THE PAPER ADD MORE WOOD REDUCE AIR CONTROLS Set to desired heat output LOW BURN RATE CONTROL Upper Right Corner AUTOMATIC COMBUSTION CONTROL ACC Middle right hand side LOW The applian...

Страница 7: ...ements of CSA B415 1 HHV includes the energy required to vaporize the water in the fuel A range of BTU outputs calculated using HHV Efficiency and the burn rates from the EPA tests using Douglas Fir d...

Страница 8: ...be maintained The appliance must be properly grounded to the frame of the mobile home with 8 copper ground wire and chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm d...

Страница 9: ...ver such as in a shed or covered with a tarp plastic tar paper sheets of scrap plywood etc as uncovered wood can absorb water from rain or snow delaying the seasoning process C Burning Process In rece...

Страница 10: ...n the stove top after start up you know the stove is hot enough and it may be time to adjust the air control if a sufficient ember bed has also been established Note that the stove will warm up much s...

Страница 11: ...Combustion Control system an over fire situation can occur and may result in a chimney fire Over firing will void the appliance warranty WARNING Injury Risk Gloves recommended CAUTION Figure 11 2 HIG...

Страница 12: ...are in the immediate area of the appliance Be sure the room is adequately ventilated and the flue unobstructed 5 Light the paper in the appliance NEVER light or rekindle fire with kerosene gasoline or...

Страница 13: ...by turning the speed control clockwise to Low or counterclockwise to High 3 Snap Disc Location If you find the blower coming on and off at undesirable temperatures relocate the snap disc to another l...

Страница 14: ...rnace and air conditioning return vents are not located in the immediate vicinity of the appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting should...

Страница 15: ...he speed is increased CONTACT YOUR DEALER for additional information regarding operation and troubleshooting Visit www quadrafire com to find a dealer Table 15 1 Fire Risk DO NOT BURN GARBAGE OR FLAMM...

Страница 16: ...very four 4 cords of wood The chimney and chimney cap must be inspected for soot and creosote every two months during the burn season or more frequency if chimney exceeds or is under 14 16 ft 4 3m 4 8...

Страница 17: ...tly if chimney exceeds or is under 14 16 ft measured from bottom of appliance By Certified Chimney Sweep Remove all ash from the firebox and extinguish all hot embers before disposal Allow the applian...

Страница 18: ...oughly cooled 4 Glass Cleaning Frequency As desired By Homeowner Clean glass with a non abrasive glass cleaner Abrasive cleaners may scratch and cause glass to crack If the deposits on the glass are n...

Страница 19: ...with the back of the firebox and even with each other in the front Ceramic Blanket Back of Firebox Baffle Board Baffle Retainer Bracket WARNING Fire Risk Firebox damage due to improper baffle placeme...

Страница 20: ...t height refer to Chimney Height Section Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Seasoned Wood Section Bed of coals not esta...

Страница 21: ...or lays flat on a soft surface 5 Remove the screws from each glass retainer and remove the glass If screws are difficult to remove soak with penetrating oil first 6 Center the glass with edges evenly...

Страница 22: ...from the firebox and extinguish all hot embers before disposal into a metal container 2 The baffle board has 2 pieces With the ceramic blanket still in place slide one baffle piece over the top of ot...

Страница 23: ...Soak the bolts with penetrating oil for at least 15 minutes before trying to remove them Ensure manifold tube gasket is placed between firebox and manifold tube assembly during re installation process...

Страница 24: ...24 08 23 7038 227L 6 Reference Materials A Service Maintenance Log Date of Service Performed By Description of Service...

Страница 25: ...25 08 23 7038 227L Date of Service Performed By Description of Service...

Страница 26: ...Beginning Manufacturing Date Sept 2017 Ending Manufacturing Date Active Step Top Wood Stove Advanced Combustion Control Part number list on following page 08 23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16...

Страница 27: ...9 Air Supply Front SRV7038 212 10 Tube Channel Rack SRV7038 174 11 Tube Channel Assembly SRV7038 008 Y 12 Secondary Tube Gasket SRV7038 187 13 Door Assembly Black DR 57BK FH Nickel Trim DR 57NL FH 13...

Страница 28: ...3 Req Pkg of 1 832 0550 Pkg of 6 832 3040 17 2 Brick 9 x 1 75 x 1 25 Qty 3 Req SRV7128 020 17 3 Brick 7 x 1 75 x 1 25 Qty 1 Req SRV7128 042 17 4 Brick 5 x 4 50 x 1 25 Qty 2 Req SRV7128 040 17 5 Brick...

Страница 29: ...ch Magnet SRV229 0631 24 6 Control Arm Assembly Rear SRV7038 004 24 7 Timer Door Control Arm Assembly SRV7038 062 Door Gasket 7033 282 Y 24 8 Timer Only Replacement Assembly SRV480 1940 Y 24 9 Timer A...

Страница 30: ...RV7033 008 Ash Pan Leg ARS SRV7033 050 Component Pack Leg Step Top Includes Gasket For Ash Removal Fasteners SRV7037 036 26 8 Legs Queen Anne Qty 4 831 1240 Qty 4 LEGS QANL 26 9 Leg Adapter Set Bracke...

Страница 31: ...Blower SRV230 0470 Y Wire Harness 7033 262 Wire Harness Blower AC SRV7000 073 Y Outside Air Kit Floor Rear OAK ACC Outside Air Collar Assembly SRV7033 039 Outside Air Shield SRV33271 Y FASTENERS Avk...

Страница 32: ...maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We...

Отзывы: