Figure 11.1
High (Open)
Low (Closed)
Burn Rate
Air Control
Start-Up Air
Control
LOW
Timer
Timer Manual
Rear Air Channel
Operates independently
from Timer
Shut-off
Shown with Side
Shield Removed
Front Air Channel
Operated by Timer
HIGH
After activating the timer (ACC), if the control is placed
within the rear air section on the label it will allow rear air
to enter the firebox. This will not interfere with the timer
gradually closing the front air channel in 25 minutes. If
control is set on “HI” it over-rides the timer (ACC).
Risk of Fire.
When set on High Burn Rate and over-riding
the Automatic Combustion Control system an
over fire situation can occur and may result in
a chimney fire.
Over firing will void the appliance warranty.
WARNING
Injury Risk.
• Gloves recommended
CAUTION
Figure 11.2
HIGH
MED
LOW
Burn Rate
Air Control
Start-Up
Air Control
Figure 11.3
Manual
Timer (ACC)
Shut Down
Pull Forward
to Shut Down
Manual Timer Over-Ride:
If you need to shut the ACC
system off before it goes through the cycle of shutting itself
off; 25 minutes, reach towards the back of the appliance
on the right side and pull the lever towards the front of the
appliance (
Figure 11.3).
Figure 11.4
Over rides timer & opens rear air to open locked
position
Open rear air medium air
flow
Engages timer push knob towards HI then back to any point within dotted line
Open rear air medium-low
air flow
Closes front and rear air