background image

 24 

 

 

 

 

                       7038-207G 

 

 

 

      September 28, 2016

5700 STEP TOP ACC

Service Parts

R

57ST-ACC-B

Beginning Manufacturing Date: Sept 2016 

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION

. Parts must be ordered from a dealer or 

distributor. 

Hearth and Home Technologies does not sell directly to consumers

. Provide 

model number and serial number when requesting service parts from your dealer or distributor.

Stocked 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

1

Air Channel, Convection

SRV7038-127

2

Air Supply Back

SRV7038-119

3

Panel Assembly Side, Left

SRV7038-006

4

Blanket, Ceramic Fiber

SRV7038-117

Y

5

Baf

 e Protection Channel (illustration on page 5)

SRV7038-179

6

Baf

 e Board

Qty: 2

SRV7038-118

Y

7

Rear Channel Assembly

SRV7038-001

8

Access Cover - ARS

SRV7038-196

9

Channel - Ash Removal System  (ARS)

7033-172

10

Tube Channel Rack

SRV7038-174

11

Tube Channel Assembly

SRV7038-008

Y

12

Secondary Tube Gasket

7038-187

13

Door Assembly

Black

DR-57BK-FH

Nickel Trim

DR-57NL-FH

14

Hinge Pins, 1/2”

Qty: 2 Gold

832-0250

Qty: 2 Nickel

430-5320

15

Glass Assembly

7000-014

Y

Glass Frame Set

GLA-FRM-5700

Gasket, Glass Tape, 3/4 “ - Field Cut to Size

5 Ft

832-0460

Y

Rope, Door, 3/4” x 84” - Field Cut to Size

7 Ft

832-1680

Y

Logo, Quadra-Fire

Pkg of 10

7000-694/10

Component Pack (Includes Nickel Spring Handles 

(1) 1/2” & (2) 1/4”, (2) Nickel Hinge Pins, Quadra-Fire 

Logo)

Black & Gold 

Doors

436-5350

Nickel Doors

436-5360

Door Handle Assemblies

Spring Handle

832-0540

Fiber Handle

SRV7033-071

Nut, Locking (For Door Handle)

Pkg of 24

226-0100/24

Y

Handle Assembly

472-5130

Cam Latch

430-1141

Key, Cam Latch

430-1151

Screw, Flat Head Philips 8-32 x 1/2

Pkg of 10

832-0860

Y

Washer, Sae, 3/8

Qty: 3 ea.

832-0990

Y

16

Brick Retainer, Side

Qty: 4

SRV7038-145

17

Heat Shield

SRV7038-211

18

Brick Assembly

See following page

Label, Start-Up Air Control

SRV7038-211

Additional service part numbers appear on following page.

Содержание 5700 STEP TOP ACC

Страница 1: ...raperies and other flammable materials away WARNING If the information in these instruc tions is not followed exactly a fire could result causing property damage personal injury or death Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance Do not over fire If appliance or chimney connector glows you are over firing Over firing will void...

Страница 2: ...nector pipe with a listed factory built UL103HT Class A chimney suitable for use with solid fuels or a masonry chimney and the referenced clearances DOUBLE WALL Six inch 6 inches 152mm diameter listed double wall air insulated connector pipe with listed factory built UL103HT Class A chimney or a masonry chimney and the referenced clearances MOBILE HOME Use double wall pipe by Dura Vent DVL Selkirk...

Страница 3: ...cations 7 2 Operating Instructions 8 A Over Firing Your Appliance 8 B Wood Selection Storage 8 C Burning Process 8 D Air Controls 9 E Using Burn Rate Air Control ACC System 9 F Burn Rates and Operating Efficiency 10 G Building A Fire 11 H Correct Baffle Blanket Placement 12 I Blower Operating Instructions 13 J Opacity Smoke 13 K Clear Space 14 L Negative Pressure 14 M Frequently Asked Questions 15...

Страница 4: ...In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period f...

Страница 5: ... does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plated...

Страница 6: ...refueling to prevent Spillage of smoke flame and carbon monoxide Spillage of sparks coals and logs Over firing DO NOT leave the appliance unattended with the door open Starting a fire may not require an open door for draft The air control should supply adequate draft 10 Pieces of Newspaper 10 20 Pieces of Dry Kindling and a Few Pieces of Dry Split Wood 1 OPEN AIR CONTROLS HIGH BURN RATE CONTROL Up...

Страница 7: ... six inch 152mm diameter liner must be used Outside Air Kit part OAK ACC must be installed in a mobile home installation Improper installation adjustment alteration service or maintenance can cause injury or property damage For assistance or additional information consult a qualified installer service agency or your dealer Quadra Fire is a registered trademark of Hearth Home Technologies WARNING F...

Страница 8: ...uch as in a shed or covered with a tarp plastic tar paper sheets of scrap plywood etc as uncovered wood can absorb water from rain or snow delaying the seasoning process C Burning Process In recent years there has been an increasing concern about air quality Much of the blame for poor air quality has been placed on the burning of wood for home heating In order to improve the situation we at Quadra...

Страница 9: ...ed on desired heat output installation configuration and fuel type 1 Burn Rate Air Control This air supply enters at the upper front of the firebox near the top of the glass door This preheated air supplies the nec essary fresh oxygen to mix with the unburned gases helping to create second third and fourth combustions This air is regulated by the Burn Rate Air Control When the control is moved all...

Страница 10: ...il the knob stops Figure 9 1 on page 9 At that point move the Burn Rate Air Control spring handle approx 1 8 1 2 up from the low position 3 Medium high burn setting Burn RateAir Control spring handle up to high position Then activate the ACC timer system by pushing the knob all the back toward the appliance to HI then pull forwards towards the front of the appliance until the knob stops Figure 9 1...

Страница 11: ...ght or rekindle fire with kerosene gasoline or charcoal lighter fluid the results can be fatal 6 Once the kindling is burning quickly add several full length logs 3 inches 76mm or 4 inches 102mm in diameter Be careful not to smother the fire Stack the pieces of wood carefully near enough to keep each other hot but far enough away from each other to allow adequate air flow between them 7 Set the Bu...

Страница 12: ...mage due to improper baffle placement is not covered by warranty Operate the wood burning appliance with the baffle in the correct po sition only Not doing so could result in Reduced efficiency Overheating the chimney Overheating the rear of the firebox Poor performance Ensure correct baffle placement and replace baffle compo nents if damaged or missing Ceramic Blanket and Baffle Board MUST be in ...

Страница 13: ... means that no smoke column can be seen As you become familiar with your appliance you should periodically check the opacity This will allow you to know how to burn as nearly smoke free as possible goal of 0 opacity WARNING Fire Risk DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPHTHA OR ENGINE OIL Do NOT burn treated wood or wood with salt drift wood May generate carbon monoxide if b...

Страница 14: ...uipment Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the appliance Avoid installing the appliance near doors walkways or small isolated spaces Recessed lighting should be a sealed can design Attic hatches weather stripped or sealed Attic mounted duct work and air handler joints and seams taped or sealed WARNING Asphyxiation Risk Negative pressure ca...

Страница 15: ... is increased CONTACT YOUR DEALER for additional information regarding operation and troubleshooting Visit www quadrafire com to find a dealer WARNING Fire Risk DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPHTHA OR ENGINE OIL Do NOT burn treated wood or wood with salt driftwood May generate carbon monoxide if burn material other than wood May result in illness or possible death Fire ...

Страница 16: ...r bill between the appliance and door and then shut the door If you can pull the dollar out remove one washer from door handle behind latch cam and try again If you can still pull it out replace the door gasket Check the glass frame for loose screws to prevent air leakage Check glass for cracks YEARLY Check the door latch for proper adjustment This is very important especially after the door rope ...

Страница 17: ...rawer below Figure 17 2 Make sure all ash is removed from the top of ARS door Lift up the grate and inspect the top of the door to ensure all ash has been removed You can rapidly move the ARS latch handle up and down to help remove any ash from the door Use a small brush to clean off the top of the door if any ash remains Be sure to replace the cap before operating the stove It is recommended to l...

Страница 18: ...ason Remove creosote to reduce risk of chimney fire Ignited creosote is extremely HOT 4 Cleaning Plated Surfaces Frequency Prior to first burn and then as desired By Homeowner 4 Glass Cleaning Frequency As desired By Homeowner Clean glass with a non abrasive glass cleaner Abrasive cleaners may scratch and cause glass to crack If the deposits on the glass are not very heavy normal glass cleaners wo...

Страница 19: ...Check for adequate vent height refer to Chimney Height Section Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Seasoned Wood Section Bed of coals not established before adding wood Start with paper kindling to establish bed of coals refer to Building a Fire Section Flue blockage such as birds nests or leaves in termination cap Hav...

Страница 20: ... first 6 Center the glass with edges evenly overlapping the open ing in the door i e same space top and bottom left and right sides 7 Replace the glass retainers Be careful not to cross thread the screws 8 Tighten each retainer just a few turns until each is secured Check again for centering of glass in door frame Continue to tighten each retainer alternately a few turns at a time until the glass ...

Страница 21: ...ve all ash from the firebox and extinguish all hot embers before disposal into a metal container 2 The baffle board has 2 pieces With the ceramic blanket still in place slide one baffle piece over the top of other one and pull out top piece through the door opening and then remove bottom baffle piece Figure 21 2 3 Remove the ceramic blanket 4 Re install the ceramic blanket and smooth out the blank...

Страница 22: ...olts from inside fire box 4 1 1 1 1 6 Baffle Boards Ceramic Blanket Baffle Protection Channel Brick Retainers Right Side Rear Brick Side Brick Tube Channel Assembly Tube Channel Nuts X3 Bolts X3 1 2 4 3 Rotate and remove from firebox NOTE Soak the bolts with penetrating oil for at least 15 minutes before trying to remove them 8 Slide the tube channel assembly to the left Drop the right side down t...

Страница 23: ...ng Manufacturing Date Sept 2016 Ending Manufacturing Date Active Step Top Wood Stove Advanced Combustion Control Part number list on following page 09 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 19 17 21 23 24 25 20 26 27 28 29 30 22 A Service Parts Accessories 6 Reference Materials ...

Страница 24: ...V7038 174 11 Tube Channel Assembly SRV7038 008 Y 12 Secondary Tube Gasket 7038 187 13 Door Assembly Black DR 57BK FH Nickel Trim DR 57NL FH 14 Hinge Pins 1 2 Qty 2 Gold 832 0250 Qty 2 Nickel 430 5320 15 Glass Assembly 7000 014 Y Glass Frame Set GLA FRM 5700 Gasket Glass Tape 3 4 Field Cut to Size 5 Ft 832 0460 Y Rope Door 3 4 x 84 Field Cut to Size 7 Ft 832 1680 Y Logo Quadra Fire Pkg of 10 7000 6...

Страница 25: ... 1 25 Qty 2 Req 18 5 Brick 7 x 1 75 x 1 25 Qty 1 Req 18 6 Brick 6 75 x 4 5 x 1 25 Qty 4 Req 18 7 Brick 5 x 4 5 x 1 25 Qty 2 Req 18 8 Brick 7 x 4 5 x 1 25 Qty 4 Req Brick Uncut Qty 1 832 0550 Qty 6 832 3040 19 Brick Retainer Rear SRV7038 148 20 Leg Mount Right Assembly 7038 028 21 Leg Mount Left Assembly 7038 029 22 Oak Cover Plate Kit SRV7038 024 23 ARS Door Assembly SRV7060 048 Y 24 Gasket ARS SR...

Страница 26: ...ar SRV7038 004 30 7 Timer Door Control Arm Assembly SRV7038 019 Door Gasket 7033 282 Y 30 8 Timer Only Replacement Assembly SRV480 1940 Y 30 9 Timer Arm Assembly 7033 034 Y 31 1 Pedestal Kit PED KIT 57 31 2 Ash Pan Pedestal Model w Door SRV7038 010 Component Pack Pedestal Step Top Includes Gasket For Ash Removal Fasteners 7038 048 Leg Kit Ash Removal System ARS Black LEG KIT BK Nickel LEG KIT NL 3...

Страница 27: ...net Round SRV7000 140 Y Snap Disc Bracket Assembly 7033 036 Snap Disc 1 Convection Blower SRV230 0470 Y Speed Control Only Rheostat 842 0370 Y Wire Harness Blower 7033 262 Blower Convection Blower Only 812 4900 Y Outside Air Kit Floor Rear OAK ACC Outside Air Collar Assembly 7033 039 Outside Air Shield 33271 Y FASTENERS Avk Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Bolt Hex Head...

Страница 28: ...operation DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com CONTACT INFORMATION This product may be covered by one or more of the following patents United States 5341794 5263471 6688302 7216645 7047962 or other U S and foreign patents pending We recommend that you record the following p...