Quadra-Fire 41I-ACC Скачать руководство пользователя страница 19

October 14, 2013 

 

 

 

           7045-910 

 

 

 

         

                  19

41I-ACC

Corner Brackets

Figure 19.2

Figure 19.1

Secure 2 Side Surrounds to 

Top Surround

Figure 19.3

SURROUND

ATTACH POINTS

STOVE TOP

E.  Surround & Trim Kit Installation

1. Lay surround face down on a protected surface to pre-

vent scratching.

2. Using a Phillips head screw driver attach the side sur-

rounds to the top surround using 2 #8 sheet metal screws 

provided with the kit. 

 Figure 19.1

3.  Lay the trim face down and place the corner brackets into 

position.

4.  Using  a  standard  flat  screw  driver  tighten  the  corner 

brackets.  

Figure 19.2

.

5.  Slide the trim over the surround set.
6. Install the surround set and trim set to the outer can.     

Place the hook in the surround sides over the surround 

attachment screws, 2 on each side. 

Figure 19.3.

7.  Place top on top of appliance.

Содержание 41I-ACC

Страница 1: ...liance Do not overfire If heater or chimney con nector glows you are overfiring Overfiring will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may...

Страница 2: ...es Needed 5 E Inspect Appliance and Components 5 F Install Checklist 6 3 Dimensions and Clearances A Appliance Dimensions 7 B Clearances to Combustibles 8 C Alternate Floor Protection Calculation 9 D...

Страница 3: ...ed trademark of Hearth Home Technologies Installation and use of any damaged appliance Modification of the appliance Installation other than as instructed by Hearth Home Technologies Installation and...

Страница 4: ...national codes and regulations Consult insurance carrier local building fire officials or authorities having jurisdiction about restrictions installation inspection and permits CAUTION WARNING DO NOT...

Страница 5: ...ir handler joints and seams taped or sealed Basement installations should be avoided D Tools And Supplies Needed Before beginning the installation be sure the following tools and building supplies are...

Страница 6: ...ght requirements Roof flashing installed and sealed Terminations installed and sealed Clearances Section 3 Pg 8 Combustible materials not installed in non combustible areas Verified all clearances mee...

Страница 7: ...ound w Cast STD 45 in 1143mm 31 in 787mm Metal Surround w Cast Trim REG 48 in 1219mm 34 in 864mm Metal Surround w Standard Trim STD 43 in 1092mm 31 in 787mm Metal Surround w Standard Trim LRG 51 in 12...

Страница 8: ...6 inch 152mm S635 flue liner required as per ULC S628 In USA a minimum 5 ft length 1 82m 6 inch 152mm diameter flue liner is required as per UL 1482 SIDE TRIM SIDE WALL TOP TRIM 22 5 8 575mm 32 1 8 81...

Страница 9: ...r k value The HIGHER the R factor means less heat is being conducted through the non combustible material to the combustible material beneath it The R value of a material must be equal or larger then...

Страница 10: ...rough the warm space enclosed by the build ing envelope This helps to produce more draft espe cially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the...

Страница 11: ...Minimum 3 ft 91cm Minimum Wall or Parapet Flat Roof F 2 10 3 Rule These are safety requirements and are not meant to assure proper flue draft This appliance is made with a 6 inch 152mm diameter chimne...

Страница 12: ...cleaning and re installation When possible install an airtight clean out door to the rear of the smoke shelf A Venting Systems Chimney Connector It is also known as flue pipe or stove pipe It must be...

Страница 13: ...ordance with Insert Listing Follow Manufacturer s Instructions for Maximum Liner Extension Above Chimney Maximum 30 Degrees Offset in Chimney Combustible Floor Masonry Chimney Cont d This insert confo...

Страница 14: ...ue collar and the chimney top The air flow of the factory built zero clearance fireplace system must not be altered The flue liner top support attachment must not reduce the air flow for the existing...

Страница 15: ...lace opening the portion of the insert extending onto the hearth must be supported Manufacturer designed adjustable support kit can be ordered from your dealer Final approval of this installation type...

Страница 16: ...ly Chimney heights exceeding 25 feet 7 62m from base of appliance may create an over draft situation Overdraft condition may create over firing Over firing may ignite creosote and or damage appliance...

Страница 17: ...tion WARNING Option One Installation Instructions The outside air cover comes packaged with the component pack It is necessary to remove the blower housing and block off the room air with the outside...

Страница 18: ...gure 18 1 2 Attach gasket to bottom side of flue collar with a thin coat of silicone C Leveling Legs 1 Remove the 2 screws already installed on each leg 2 Move legs to the desired height 3 Re install...

Страница 19: ...w driver attach the side sur rounds to the top surround using 2 8 sheet metal screws provided with the kit Figure 19 1 3 Lay the trim face down and place the corner brackets into position 4 Using a st...

Страница 20: ...0 1 3 Using phillips head screw driver remove snap disc bracket and cord restraint bracket from right side Figure 20 2 4 Re install snap disc bracket and cord restraint bracket to left side of blower...

Страница 21: ...eet metal shears cut trim along the marked edge The cut edge fits under lip of top trim so it allows for some variance in your straight edge 5 The double sided tape that holds front and side trims to...

Страница 22: ...from each side of insert and use plumbers tape to secure to structure a washer may be required Re install bolts 3 Unit must be grounded with 8 solid copper grounding wire or equivalent and terminated...

Страница 23: ...ludes Door Trim Spring Handle Hinge Pins And Logo Gold 41IDRTRIM GD Nickel 41IDRTRIM NL D T S C C A I 1 4 P S y l e t a r e p e S t i K m i r T r e d r O 1 3 X 3 4 d n u o r r u S Surround Trim Kit 43...

Страница 24: ...mportant operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instruc tions for safe installa tion and opera...