18
7045-910
October 14, 2013
41I-ACC
Flue Collar
Stove Pipe/Liner
Gasket
Figure 18.1
Remove 2 screws from both sides.
Adjust the legs up or down to level
appliance.
Figure 18.2
5/16 Nuts
Attachment
Bar
5/16 Bolts
Figure 18.3
B. Securing Stove Pipe/Liner to Flue Collar
1. There are 4 pre-drilled holes in the flue collar 90 degrees
apart. Attach the flue collar to the stove pipe/liner. If the
seal is questionable use high temperature sealant such
as stove mastic
Figure 18.1.
2. Attach gasket to bottom side of flue collar with a thin coat
of silicone.
C. Leveling Legs
1. Remove the 2 screws already installed on each leg.
2. Move legs to the desired height
.
3. Re-install the screws to secure in place.
D. Securing Appliance to Stove Pipe/Liner
1. Once you have the appliance in place and secured, reach
up through the flue opening and grab the attachment bar
and pull down inside flue opening.
Figure
18.3
.
2. Insert the 5/16 bolts inside the cast flue and through the
chimney mounting bar. Securely tighten the nuts. Fas-
teners are provided.
3. Re-install the tube channel assembly, baffle board,
ceramic blanket and baffle protection channel.