Leveling Bolts

Sheet Metal Shims

Place under leveling bolts 
and slide insert into place

Leveling Bolt

Reach between side of insert and outer skin

cut-out view

This product shipped with two leveling bolts, and two sheet 
metal guides for ease in sliding the insert into place when 
using the leveling bolts.  Not all installations will require the 
use of the leveling bolts.  The sheet metal guides are used 
only when the leveling bolts are necessary.   Discard if not 
needed.

ADJUSTING THE LEVELING BOLTS

It is best to use a 1/2 inch (12.7mm) socket wrench with an 
extended handle for ease in adjusting bolts to the desired 
level.  The bolts will adjust from 0 to 2 inches (0 - 51mm).  
You can also reach in and adjust the bolts by hand, although 
space is limited.  

Figure 12A.

 LEVELING BOLTS AND SHEET METAL SHIMS

SHEET METAL GUIDES

Slide each guide under the insert on each side placing 
them directly under leveling bolts.  If they are not directly 
under the bolts, the bolts may hang up on uneven material 
when sliding the insert into place.  

See Figure 12B.

Figure 12A

Figure 12B

INSTALLATION IN CANADA

 

  

MASONRY and HEAT-CIRCULATING

(INSTALLATIONS INTO FACTORY-BUILT FIREPLACES ARE PROHIBITED IN CANADA)

Whether installed in a masonry or heat-circulating fi replace, this fi replace insert must be installed with a continuous chim-
ney liner of six inch (152mm) diameter extending from the fi replace insert to the top of the chimney. The chimney liner must 
conform to the Class 3 requirements of CAN/ULC-S635, Standard for Lining Systems for Existing Masonry 

or Factory-Built 

Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.

 

• Do not remove bricks or mortar from fi replace to accommodate insert.  

• The face of the fi replace must be sealed to prevent room air passage into the chimney cavity.

• The permanent metal warning label provided must be affi xed to the back of the fi replace with screws or nails to 

the fi replace, in a location readily visible should the fi replace insert by removed, stating that the fi replace may 
have been altered to accommodate the insert, and must be returned to original condition for use as a conven-
tional fi replace.

• Circulating air chambers may not be blocked.

Содержание 4100I-GD-B

Страница 1: ...ogy ACT O T O T L Tested and Listed by Beaverton Oregon USA OMNI Test Laboratories Inc C US 250 7201D March 27 2008 1445 North Highway Colville WA 99114 2008 R Installation and service of this applian...

Страница 2: ...LES LABEL LOCATION Back side of left side panel Manufactured Date Serial Number Model Name Test Lab Report No Model 4100 I 4100 I INSERT INSERT Serial No Num ro De S rie O T O T L Tested and Listed by...

Страница 3: ...o Chimney Ring 13 PARTS ACCESSORY INSTALLATION Outside Air Installation 13 Panel Sets and Trim Sets 14 Blower Cord Installation 15 Blower Control Box with Switch 15 Fan Blower Replacement 15 Zero Clea...

Страница 4: ...MENSIONS TOP VIEW SIDE VIEW FRONT VIEW 20 7 8 530mm 30 o 10 7 8 276mm 21 5 8 549mm 7 7 8 200mm 16 1 4 413mm C L 24 610mm 30 762mm 12 1 8 308mm 9 5 16 135mm 45 3 4 1162mm A B 30 7 8 784mm 44 3 4 1137mm...

Страница 5: ...kness k value 0 84 or equivalent material Zero Clearance Installations USA Only Omni Report 061 S 40 2 In Canada a full length six inch 152mm S635 flue liner required as per ULC S628 CLEARANCES TO COM...

Страница 6: ...RECOMMENDATIONS These installation instructions describe the installation and operation of the Quadra Fire 4100 I Wood Insert This insert meets the U S Environmental Protection Agency s 1990 particul...

Страница 7: ...ue is convenient when more than one material is used since you can add the R values together whereas you can not do this for k value The HIGHER the R factor means less heat is being conducted through...

Страница 8: ...f or structure that is within10 feet 305cm of the chimney measured hori zontally Refer to Figure 8C CHIMNEY REQUIREMENTS Non combustible fire stopping material Minimum 2 inch 51mm clearance from combu...

Страница 9: ...ust be followed precisely 7 Use silicone to create an effective vapor barrier at the location were the chimney or other component penetrates to the exterior of the structure 8 Follow the chimney and c...

Страница 10: ...hould also be checked to ensure it meets the minimum standard of the National Fire Protection Association NFPA Standard 211 The following bullets list the more critical requirements for a properly con...

Страница 11: ...ly attached to the insert flue collar and the chimney top To prevent room air passage to the chimney cavity of the fireplace seal either the damper area around the chimney liner with high temperature...

Страница 12: ...up on uneven material when sliding the insert into place See Figure 12B Figure 12A Figure 12B INSTALLATION IN CANADA MASONRY and HEAT CIRCULATING INSTALLATIONS INTO FACTORY BUILT FIREPLACES ARE PROHIB...

Страница 13: ...4 NOTE Tabs are shipped from factory in a flat position Bend upwards 90 degrees Figure 13A Tools Needed Phillips Head Screwdriver 1 Remove three screws and cover plate from back side of insert Save t...

Страница 14: ...sert with 8 32 sheet metal screws through tabs on bottom lower inside corners on side panels Figure 13B Included in Panel Kit 2 side panels left and right 1 panel top 2 trim pieces 1 trim top 1 fasten...

Страница 15: ...wards you See Figure 15D 2 Loosen 4 screws 2 on each side of the motor that secures motor to the housing Remove the motor See Figure 15E 3 Attach new motor using the same screws to the blower housing...

Страница 16: ...r top lip and into position on scis sors Place side pieces on first and then front piece The front piece overlaps side pieces NOTE The trim in the Flush Mount Kit is one piece 7 Once you are satisfied...

Страница 17: ...OPERATION Before lighting your first fire in the insert make certain that the baffle is correctly positioned It should be resting against the rear support Also refer to care and cleaning of plated su...

Страница 18: ...especially important to fully open both controls when reload ing the insert as failure to do so could result in excessive emissions also referred to as opacity After a wood load has been burning on hi...

Страница 19: ...irst 5 to 15 minutes Second Stage The next stage of burning the secondary stage is the period when the wood gives off flammable gases which burn above the fuel with bright flames During this stage of...

Страница 20: ...entering of glass in door and or side frames and give all screws a final tightening CREOSOTE FORMATION AND NEED FOR REMOVAL When wood is burned slowly it produces tar and other organic vapors which co...

Страница 21: ...ceramic blanket from above the baffle 3 With a 3 16 Allen wrench remove 2 front manifold tube retainer bolts on the air channel under the end of the front tubes NOTE Soak the bolts with penetrating o...

Страница 22: ...em Description 1 Ashcatcher 8 Baffle Fiberboard 15 Flue Tab 2 Blower 180 cfm 9 Ceramic Blanket 1 2 16 Top Cast 3 Blower Mount Base 10 Door Latch Box Assembly 17 Brick 2 with holes 4 Blower Housing Cas...

Страница 23: ...ual Touch up Paint Warranty Card Door Handle 2 Screws Permanent Label If Fireplace Altered 435 5310 19 Door Assembly with Glass Gold 435 5190 19 Door Assembly with Glass Nickel 435 5300 19 Door Assemb...

Страница 24: ...w SP BB3044 GD Panel Trim Set Nickel Small 30 1 2 h x 44 5 8 w SP BB3044 NL Zero Clearance Trim Support Adjustable 9 d x 45 w 2 10 high 841 0990 Zero Clearance Trim Support Adjustable 12 d x 50 w 2 10...

Страница 25: ...Page 25 March 27 2008 4100 I ACT WOOD INSERT 250 7201 Rev D R Date of Service Performed By Description of Service Service and Maintenance Log...

Страница 26: ...4100 I ACT WOOD INSERT Page 26 March 27 2008 R 250 7201 Rev D Consumer s Notes...

Страница 27: ...ome Technologies discontinues the model and two 2 years for optional accessories Adjustments regular maintenance cleaning and temporary repairs do not qualify for a service call fee and will not be co...

Страница 28: ...B2 6729551 6736133 6748940 6748942 D320652 D445174 D462436 Canada 1297749 2195264 2225408 or other U S and foreign patents pending Hearth Home Technologies 1445 North Highway Colville WA 99114 Divisio...

Отзывы: