3100 Millennium Wood Appliance
F
igure 10.1
High (Open)
Low (Closed)
Start-Up Air
Control
Burn Rate
Air Control
Front Air Channel
Operated by Timer
RearAir Channel
Operates independently
from Timer
HIGH
LOW
Timer
Timer Manual
Shut-off
Shown with Side
Shield Removed
After activating the timer (ACC), if the control is placed within
the rear air section on the label it will allow rear air to enter
the firebox. This will not interfere with the timer gradually
closing the front air channel in 25 minutes. If control is set
on “HI” it over-rides the timer (ACC).
F. Burn Rates and Operating Efficiency
For maximum operating efficiency
This wood appliance has a manufacturer-set minimum low
burn rate that must not be altered. It is against federal reg-
ulations to alter this setting or otherwise operate this wood
appliance in a manner inconsistent with operating instructions
in this manual.
• Burn dry, well-seasoned wood.
Burn Rates
1.
Low burn setting:
• Burn Rate Air Control spring handle up to high position
for 5 minutes.
• Then activate the ACC timer system by pushing the
knob all the back toward the appliance to “HI” then pull
forwards towards the front of the appliance until the
knob stops
(Figure 9.1 on page 9)
.
• At that point close the Burn Rate Air Control by moving
the spring handle to the low setting.
2.
Medium low burn setting:
• Burn Rate Air Control spring handle up to high position
for 5 minutes.
• Then activate the ACC timer system by pushing the
knob all the back toward the appliance to “HI” then
pull forwards towards the front of the appliance until
the knob stops.
• At that point move the Burn Rate Air Control spring
handle to 1/8”-1/2” from the low setting.
3.
Medium high burn setting:
• Burn Rate Air Control spring handle up to high position.
• Then activate the ACC timer system by pushing the
knob all the back toward the appliance to “HI” then
pull forwards towards the front of the appliance until
the knob stops.
• At that point move the Burn Rate Air Control spring
handle to 1/2” – high.
4.
High burn setting:
• Burn Rate Air Control spring handle up to high position
• Also activate ACC timer system knob pushed back to
the “HI” position.
Note:
If using the optional blower use burn settings 1-3
burn settings the blower shall be off for the first 30 minutes
and then be operated in the high position at 30 minutes.
For high burn setting, blower may continue to be on full
after the loading of the fuel.
NOTE:
The above information is provided as a guide-
line only. Altitude and other circumstances may require
control adjustments to achieve the desired burn rates.
NOTE:
Operate appliance on High Burn 45 minutes a
day to help keep flue/chimney clean.
WARNING
Risk of Fire.
When set on High Burn Rate and over-riding the Auto-
matic Combustion Control system an over fire situation
can occur and may result in a chimney fire.
Over firing will void the appliance warranty.