Page 4
7033-308D
March 4, 2015
3100 Series ACC Wood Burner
DESCRIPTION
Pioneer Double Flue Mounted Shield Universal
Shall be Fitted
With Double Flue
Shield Fitted
A
Min. Clearance from back of unit to rear wall
175mm
B
Min. clearance from center of spigot to rear wall
345mm
C
Min. distance from front of base to
fl
oor protector front
300mm
D
Min.
fl
oor protector front width
800mm
E
Min. distance from rear wall to front of
fl
oor protector
1062mm
F
Min. distance from unit side to side wall
360mm
G
Min. clearance from center of spigot to side wall
668mm
Quadra-
fi
re 3100 Millenium and 3100 LE ACC produdcts do not require a insulating Floor Protector,
as they are tested and comply with the minimum Floor Protector requirements of
AS/NZS 2918:2001.
Note:
▪
The minimum Floor Protector sizes are speci
fi
ed in the clearance chart, see Table 1 & 2.
▪
A Floor Protector can include ceramic tiles with grouted joints
fi
xed directly onto a wooden
fl
oor or
a sheet of toughened glass, panel steel or any other non combustible material laid directly onto a
wooden
fl
oor.
▪
If installed directly onto a concrete slab, the concrete slab can be considered as the
fl
oor
protector,but must maintain the minimum measurement listed.
FLOOR PROTECTOR - 31M and 31LE
PARALLEL POSITIONNG - 31M and 31LE
NOTE: HEAT SHIELD REQUIREMENTS FOR HEAT SENSITIVE WALLS
Clearances may be reduced by provision of an appropriately located heat shield refer to
AS/NZS 2198:2001 3.2.3 TABLE 3.1
Table 1
Fig. 3
FLOOR PROTECTOR
B
C
D
F
E
A
G
REAR WALL
SIDE W
ALL
REAR W
ALL