WARNINGS:

WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE 
WITH AS/NZS 2918 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING 
CODE OR CODES.

WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL 
COMPLY WITH THE REQUIREMENTS  OF AS/NZS 4013 WHERE REQUIRED BY THE REGULA-
TORY AUTHORITY, I.E. THE APPLIANCE SHALL BE IDENTIFIABLE BY A COMPLIANCE PLATE 
WITH THE MARKING ‘TESTED TO AS/NZS 4013’.

ANY MODIFICATION  OF THE APPLIANCE  THAT HAS NOT BEEN APPROVED  IN WRITING BY 
THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED 
FOR COMPLIANCE WITH AS/NZS 4013.

CAUTION: MIXING OF APPLIANCE  OR FLUE SYSTEM COMPONENTS  FROM DIFFERENT 
SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY 
RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED,      THE MAN-
UFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE.

CAUTIONS: CRACKED AND BROKEN COMPONENTS,  e.g. GLASS PANELS OR CERAMIC TILES, 
MAY RENDER THE INSTALLATION UNSAFE.

WARNING: ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN 
WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS/NZS 4013.

WARNING:  DO  NOT  USE  FLAMMABLE  LIQUIDS  OR  AEROSOLS  TO  START  OR  REKIN-
DLE  THE FIRE.

WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS 
APPLIANCE WHEN ITS OPERATING.

WARNING: DO NOT STORE FUEL WITHIN HEATER INSTALLATION CLEARANCES.

WARNING: FOR OPTIMUM PERFORMANCE FUEL MUST BE LOADED SO THE LOGS LAY 
“FRONT TO REAR” IN PREFERENCE  TO LAYING ACROSS THE WIDTH OF THE FIREBOX. 
SPACES SHOULD BE LEFT BETWEEN THE LOGS TO ENABLE OXYGEN TO GET TO AS MUCH 
OF THE SURFACE OF THE FUEL AS POSSIBLE.

CAUTION: THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN 
ACCORDANCE WITH THESE INSTRUCTIONS.

CAUTION: THE USE OF SOME TYPES OF PRESERVATIVE-TREATED WOOD AS A FUEL CAN BE 
HAZARDOUS.

AS/NZS 2918:2001 General Notes

Содержание 31M-ACC-AU

Страница 1: ...e systems as per AS NZS 2918 2001 Appendix F with a ceiling angle between 0 30 inclusive For installations with a ceiling angle greater than 30 refer to Fig 7 8 and AS NZS 2918 2001 4 6 3 b Ceiling Pl...

Страница 2: ...fort of your hearth appliance Thank you for choosing Quadra Fire and Welcome to the Quadra Fire Family 3100 Series ACC JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2015 2016 2017 INSTALLATION DATE...

Страница 3: ...re 3100 Millenium ACC Wood Burner Dimensions 616 mm 533 mm 254 mm 457 mm 273 mm 397 mm 379 mm 484 mm 749 mm 90 mm 25 mm 499 mm 406 mm 677 mm 46 mm Quadra Fire 3100 Limited Edition ACC Wood Burner Dime...

Страница 4: ...are tested and comply with the minimum Floor Protector requirements of AS NZS 2918 2001 Note The minimum Floor Protector sizes are specified in the clearance chart see Table 1 2 A Floor Protector can...

Страница 5: ...m corner wall 756mm E Min floor protector front width 800mm F Min overall floor protector depth 1469mm CORNER POSITIONING 45 31M and 31LE Table 2 Fig 4 FIREBOX INSTALLATION 1 If a separate floor prote...

Страница 6: ...308D March 4 2015 3100 Series ACC Wood Burner Quadra Fire 31 Step Top ACC Wood Burner Dimensions 678mm 618mm 391mm 292mm 406mm 527mm 870mm 635mm 318mm 237mm C L 457mm 606mm 841mm 194mm 537mm 264mm 170...

Страница 7: ...and comply with the minimum Floor Protector requirements of AS NZS 2918 2001 Note The minimum Floor Protector sizes are specified in the clearance chart see Table 3 4 A Floor Protector can include ce...

Страница 8: ...om corner wall 661mm E Min floor protector front width 800mm F Min overall floor protector depth 1335mm CORNER POSITIONING 45 31 Step Top Table 4 Fig 6 FIREBOX INSTALLATION 1 If a separate floor prote...

Страница 9: ...a phillips screwdriver to remove 4 screws on back Fig 14 1 3 Using a 11mm socket or wrench remove 4 wood lag bolts located in corners of pedestal base Fig 14 2 4 Lift stove off of pallet and reassemb...

Страница 10: ...eptable Solution from 01 07 05 5 Install the outer casing so that i lower end is flush with the underside of the ceiling material and ii with the addition of metal L brackets affix to the outer casing...

Страница 11: ...combustible material Non combustible material Hebel block or 12mm Promina board or similar under the flashing 25 25 Approved Flashing Roof Line Inner Casing 200mm above roof line Outer Casing Inner Ca...

Страница 12: ...ownward distance of casing and 3 x flue distance of the ceiling plate ADD Cowl Casing Cover Spider Bracket Approved Flashing A Ceiling Plate Batten A 3 x flue pipe Ceiling flue pipe Fig 7 ADD Cowl AS...

Страница 13: ...entral tongue to locate inside the flue outlet only Two tabs are provided and if folded back at 90 degrees the bracket and Flue Mounted Shield will mount lower onto the appliance The Flue Mounted Shi...

Страница 14: ...ION IS CONSIDERED THE MAN UFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTIONS CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE WARNING ANY MO...

Страница 15: ...under this manufacturer s warranty begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occu...

Страница 16: ...otes DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instr...

Отзывы: