18
7044-225B
April 9, 2014
31-I ACC
B. Disassemble Firebox and Outer Can
For easier field installation the outer can is installed with-
out the firebox so connecting to the flue has greater access.
The firebox slides into the outer can once the flue collar is
attached to the stove pipe/liner and optional outside air flex
pipe is installed.
1. Remove the flue collar by cutting the wire ties. Set the
flue collar and attachment bar aside.
2. Remove the 2 screws holding the timer assembly in place
and remove the timer.
Figure 18.1
.
3. Remove the 2 Phillips head bolts underneath the ashlip
which holds the firebox in place.
4. Slide the firebox out of the outer can.
5. Remove the 2 pallet lag bolts.
Firebox
Timer Assembly
Outer Can
Phillips Head Bolts
Pallet
Lag
Bolts
Flue Collar
Attachment Bar
Figure 18.2
Timer Screws
Figure 18.1
Содержание 31I-ACC