- 16 -
1.6 Display Codes
During normal operation, the
ES500
control displays its current status via the display as follows:
Id Idle, awaiting open command
SA
SAfety device active, door prohibited from opening
OS
Opening door at Open Speed
OC
Opening door at Open Check speed
HO
Holding Open
OP
Manual Opening detected (with PG turned off)
CL
CLosing door, with speed set by close speed adjustment
LC
Closing door at Latch Check speed, latch check delay running
SS
Opening door at Seek Speed (following obstruction)
Ob
Obstruction detected, door stalled
**
d1
Time delay 1 in use (delay for hold open time)
*
d2
Time delay 2 in use (delay for push and go actuation)
*
d3
Time delay 3 in use (delay for touch-stop recycle)
*
The normal display sequence during a cycle is
OS
–
d1
(or
d2
)
–
OC
–
HO
, then
CL
–
LC
–
Id
.
1.7 Parameter List
The following list shows all adjustable parameters in the
ES500
control, along with a brief
description of their function and their factory default values.
OS
Open Speed. Sets the opening speed of the door before the open check switch is released.
Possible values are 0-15, and default is 4.
OC
Open Check. Adjusts from 0-15. Default is 9. Determines opening speed after the open check
switch is released (within the last 15-45° of door opening).
HO
Hold Open. Adjusts from 0-15. Default is 3. Should be adjusted to the minimum
POWER
(not
time) required to keep the door from drifting closed after the display switches to
HO
.
SS
Seek Speed. Adjusts from 0-15. Default is 5. Should be adjusted to make the door creep open
following the "obstruction" response (see Section 1.4).
AC
ACceleration. Determines how fast the door ramps up to open speed following an actuate
command. Possible values are 0-15, and the setup default is 15 (maximum acceleration).
dC
decceleration. Determines how fast door slows down after the open check switch is released.
Possible values are 0-15. The setup default of 0 switches door immediately from "speed" to "check"
with no ramp-down.
UJ
UnJam power. Determines amount of power the control applies in the closing direction to unjam
the lock and/or door prior to opening. Possible values are 0-16, and the setup default is 0 (do not
apply unjam power). Note that unjam power may be used with or without a lock present.
d2
Time delay 2 (push and go). This delay is used only when the door has been actuated by a push
and go signal. The time delay begins when the door reduces speed to open check. Possible values
are 1-99 seconds and the setup default is 1 second.
Note:
d1
takes priority over
d2
. If the door is opened via push and go, then a standard actuating
signal (pushbutton etc.) is received,
d1
replaces
d2
.
d3
Time delay 3 (close recycle). This delay is used only when the door has been recycled by an
obstruction detected while attempting to close. The time delay begins when the door reduces speed
to open check. Possible values are 1-99 seconds, and the setup default is 1 second.
Содержание EZ-7000
Страница 2: ... 2 ...
Страница 4: ... 4 ...
Страница 7: ... 7 ...
Страница 8: ... 8 ...
Страница 11: ... 11 Installing Power Arm and Rod Prepare Power Arm and Rod as per drawings and charts ...
Страница 12: ... 12 ...
Страница 19: ... 19 ...
Страница 20: ... 20 ...
Страница 21: ... 21 Lock with No Transformer not recommended Lock with Transformer recommended ...
Страница 22: ... 22 ...
Страница 23: ... 23 BEA Technical Support East Region 866 836 1863 West Region 888 419 2564 ...
Страница 24: ... 24 Optex Technical Support 800 966 7839 ...
Страница 25: ... 25 Optex Technical Support 800 966 7839 904C ...
Страница 28: ... 28 ...