- 16 - 

1.6 Display Codes 

During normal operation, the 

ES500

 control displays its current status via the display as follows: 

Id Idle, awaiting open command 
 

SA

 SAfety device active, door prohibited from opening 

OS

 Opening door at Open Speed 

OC

 Opening door at Open Check speed 

HO

 Holding Open 

OP

 Manual Opening detected (with PG turned off) 

CL

 CLosing door, with speed set by close speed adjustment 

LC

 Closing door at Latch Check speed, latch check delay running 

SS

 Opening door at Seek Speed (following obstruction) 

Ob

 Obstruction detected, door stalled

**

 

d1

 Time delay 1 in use (delay for hold open time)

 *

 

d2 

Time delay 2 in use (delay for push and go actuation)

 *

 

d3

 Time delay 3 in use (delay for touch-stop recycle)

 * 

 
The normal display sequence during a cycle is 

OS

 

– 

d1

 (or 

d2

– 

OC

 

– 

HO

, then 

CL

 

– 

LC

 

– 

Id

.  

 

1.7 Parameter List

 

The following list shows all adjustable parameters in the 

ES500

 control, along with a brief 

description of their function and their factory default values. 
 

OS

 Open Speed. Sets the opening speed of the door before the open check switch is released. 

Possible values are 0-15, and default is 4. 

OC

 Open Check. Adjusts from 0-15. Default is 9. Determines opening speed after the open check 

switch is released (within the last 15-45° of door opening). 

HO

 Hold Open. Adjusts from 0-15. Default is 3. Should be adjusted to the minimum 

POWER 

(not 

time) required to keep the door from drifting closed after the display switches to 

HO

SS

 Seek Speed. Adjusts from 0-15. Default is 5. Should be adjusted to make the door creep open 

following the "obstruction" response (see Section 1.4). 

AC

 ACceleration. Determines how fast the door ramps up to open speed following an actuate 

command. Possible values are 0-15, and the setup default is 15 (maximum acceleration). 

dC

 decceleration. Determines how fast door slows down after the open check switch is released. 

Possible values are 0-15. The setup default of 0 switches door immediately from "speed" to "check" 
with no ramp-down. 

UJ

 UnJam power. Determines amount of power the control applies in the closing direction to unjam 

the lock and/or door prior to opening. Possible values are 0-16, and the setup default is 0 (do not 
apply unjam power). Note that unjam power may be used with or without a lock present. 

 
d2 

Time delay 2 (push and go). This delay is used only when the door has been actuated by a push 

and go signal. The time delay begins when the door reduces speed to open check. Possible values 
are 1-99 seconds and the setup default is 1 second.

  

 

Note:

 

d1

 takes priority over 

d2

. If the door is opened via push and go, then a standard actuating 

signal (pushbutton etc.) is received, 

d1

 replaces 

d2

 

d3

 Time delay 3 (close recycle). This delay is used only when the door has been recycled by an 

obstruction detected while attempting to close. The time delay begins when the door reduces speed 
to open check. Possible values are 1-99 seconds, and the setup default is 1 second. 

Содержание EZ-7000

Страница 1: ... and Installation Manual For QUAD EZ 7000 LOW ENERGY AUTOMATIC SWING DOOR OPERATOR PLEASE READ THIS ENTIRE MANUAL AND FOLLOW ALL GUIDELINES TO ENSURE PROPER INSTALLATION AND SAFETY PROUDLY DISTRIBUTED BY ANSI UL 991 325 CAN CSA 27 Listed REV 1 29 19 ...

Страница 2: ... 2 ...

Страница 3: ... to the stop position when closed manually if wired correctly 4 Plug in power supply Turn HOA switch to the HOLD position The motor should open to the full hard stop position 5 Install arm and check the outside cam The cam switch arm should be in the down position flat part of cam 6 Turn power off and let door close completely Check inside cam The switch should be in the down position flat part of...

Страница 4: ... 4 ...

Страница 5: ...or system in compliance with the industry standards for safety It is your responsibility as owner or caretaker of the equipment to inspect the operation of your door system on a daily basis and after any loss of electrical power to ensure that it is safe for use by your invitees customers or employees Daily Safety Checks are the responsibility of the equipment owner or caretaker The Following safe...

Страница 6: ... shall not apply to such products which have been altered or repaired by other than an authorized agent Authorization shall be in writing by Quad Systems LLC Warranty does not apply if products have been subject to misuse negligence or accident There is no expressed or implied warranty by Quad Systems LLC except as specifically stated above Quad Systems LLC shall not be liable for special or conse...

Страница 7: ... 7 ...

Страница 8: ... 8 ...

Страница 9: ...operates 120 volt electrical supply supplied by others in accordance with all local codes This unit must be grounded Do NOT connect opener to source of power until instructed to do so Step One Mounting the Header Make sure the mounting area has proper support for the unit Wood studs or blocking in wallboard is recommended On each side of the door frame the header should overlap by 1 on each side I...

Страница 10: ... in or serious damage could be inflicted on the Controller as well as the installer Install the Hold Open Automatic HOA switch into the end cap hole provided on each end and plug in wiring harness from switch and operator into marked pins WARNING Do NOT connect opener to source of power until instructed to do so NOTE At this point do not install any other device into the controller i e switch harn...

Страница 11: ... 11 Installing Power Arm and Rod Prepare Power Arm and Rod as per drawings and charts ...

Страница 12: ... 12 ...

Страница 13: ...devices will be wired in a later step If a lock is present temporarily disable it to keep it from jamming the door while setting up the operator 2 0 Initial Setup WARNING In the next step you will be applying power to the operator in order to install the operator arm Avoid all moving parts Turn the unit on and set the on off hold switch to the Hold position Physically inspect the operator to ensur...

Страница 14: ...n off hold switch to the Hold position and let the door fully open Physically inspect the open check switch switch with orange and yellow wires and its associated cam The switch arm should be on the CENTER flat side of the cam The arm of the open check switch should remain depressed until the door is approximately 30 from the full open position and then it must release Do not proceed further until...

Страница 15: ...eeps open following an obstruction response timeout Note If the LIMIT adjustment is turned up too far it may not be possible to get the obstruction response 1 5 Actuating Accessory Wiring Remove power from the control Wire the actuating device s to ACT connector CN2 as shown in the wiring diagram Note that total accessory device current draw should be limited to 0 5A or less A radio receiver may b...

Страница 16: ...ired to keep the door from drifting closed after the display switches to HO SS Seek Speed Adjusts from 0 15 Default is 5 Should be adjusted to make the door creep open following the obstruction response see Section 1 4 AC ACceleration Determines how fast the door ramps up to open speed following an actuate command Possible values are 0 15 and the setup default is 15 maximum acceleration dC deccele...

Страница 17: ... speeds This reduces all open speed settings by approximately 50 allowing the use of very slow open speeds if desired Remaining speeds open check hold open etc are not affected by SL Default is off use normal open speeds LL Lock present When the LL parameter is on the control will trigger the lock relay prior to opening It will also attempt to unjam the door if requested see the UJ and UP paramete...

Страница 18: ...pening power will be somewhat higher with a door attached to the operator A conservative estimate would be a factor of roughly two times the given figure 0 82 amperes or 112 watts for any reasonable door weight up to 100 125 pounds The control has a 3 15 ampere fuse so in no case will the prolonged current draw be more than this figure as the fuse would blow Another question which seems to be aske...

Страница 19: ... 19 ...

Страница 20: ... 20 ...

Страница 21: ... 21 Lock with No Transformer not recommended Lock with Transformer recommended ...

Страница 22: ... 22 ...

Страница 23: ... 23 BEA Technical Support East Region 866 836 1863 West Region 888 419 2564 ...

Страница 24: ... 24 Optex Technical Support 800 966 7839 ...

Страница 25: ... 25 Optex Technical Support 800 966 7839 904C ...

Страница 26: ...lation instructions Q How do I easily adjust the cams A Place switch on Hold Open position and let the door open to the full open position Loosen the small Allen head screws on the outside cam switch with 2 wires Rotate the cam until the switch is on the flat part of the cam and tighten screw Place switch in the Off o position and let the door close completely Loosen the small Allen head screws on...

Страница 27: ...ontrol in a high energy mode this feature is supported beginning in Versions 1 02 1 03 An auxiliary harness Close Monitor harness part number 600 0008 01 will be required Set the AF parameter to 3 Wire the safety beam s output contact to the red and black wires of the auxiliary harness A beam break will prevent the door from opening if it s closed prevent it from closing if it s open slow the door...

Страница 28: ... 28 ...

Отзывы: