background image

- 14 - 

 

Important

: Be sure to save any changes you make before leaving the jobsite! 

Changes are not 

stored in the ES500 control’s permanent memory until you save them. 

To save your 

parameters, with the door in normal operation, press 

and hold 

the 

SET

 button until the display 

winks 

dS

 (data Saved). Your parameters are now stored in the contr

ol’s permanent memory. 

 

WARNING

: The 

LIMIT, OBST, CLS 

SPD, and 

LAT SPD

 screwdriver adjustments are in close 

proximity to electrically hot parts. Be careful to avoid contact with any parts while making 

adjustments. 

 

1.3 Closing Adjustments 

After the arm is installed, turn the 

on/off/hold 

switch to the

 

“Off” 

position. The door will close. 

Physically inspect the latch check switch (switch with the blue, gray, and white wires) and its 
associated cam. The switch arm should be on the CENTER flat side of the cam. (

The arm of the 

latch check switch should remain depressed from the full open position until the door is 
approximately 
10-15° from the full closed position, and then it must release.) 

Adjust the cam 

as necessary. Next, adjust the 

CLS SPD

 (close speed) and 

LAT SPD

 (latch speed) pots for the 

desired closing operation. 

DO NOT ADJUST WHEN THE DOOR IN IN MOTION

. The door may be 

manually opened as many times as necessary to complete these adjustments. 

 

 

1.4 Opening Adjustments 

Turn the 

on/off/hold 

switch to the

 

“Hold” 

position and let the door fully open. Physically inspect the 

open check switch (switch with orange and yellow wires) and its associated cam. The switch arm 
should be on the CENTER flat side of the cam. (

The arm of the open check switch should 

remain depressed until the door is approximately 30° from the full open position, and then it 
must release
.) 

Do not proceed further until you have verified the adjustment of this cam. 

Temporarily set both the 

LIMIT

 pot and the 

OBST

 pot fully counterclockwise. Insure that the 

on/off/hold

 switch is in the 

ON

 position.  

 
If the display is upside down, unplug the unit, press 

and hold 

the

 bottom

 button while plugging the 

power connector back into 

CN9

 on the control until it lights up, then release. This will flip the display. 

 

HINT

: If the door remains closed but the display does not switch to 

Id

, insure that the latch check 

cam has been adjusted properly (Section 1.3, Closing Adjustments) and that the rocker switch is in 
the 

ON

 position. If the door tries to open, insure that the rocker switch is not in the 

HOLD

 position 

instead of the 

ON

 position. 

 
Cycle the door by pressing and holding the 

DOWN

 button (this button functions as an actuate signal 

when the door is in normal operation, allowing easier testing). The door should cycle open. The 
display will show 

OS

 (Open Speed) before the open check switch releases. It will switch to 

OC

 

(Open Check) in the open check zone. If the 

DOWN

 button is held long enough, the display will 

switch to 

HO

 (Hold Open). 

 

Содержание EZ-7000

Страница 1: ... and Installation Manual For QUAD EZ 7000 LOW ENERGY AUTOMATIC SWING DOOR OPERATOR PLEASE READ THIS ENTIRE MANUAL AND FOLLOW ALL GUIDELINES TO ENSURE PROPER INSTALLATION AND SAFETY PROUDLY DISTRIBUTED BY ANSI UL 991 325 CAN CSA 27 Listed REV 1 29 19 ...

Страница 2: ... 2 ...

Страница 3: ... to the stop position when closed manually if wired correctly 4 Plug in power supply Turn HOA switch to the HOLD position The motor should open to the full hard stop position 5 Install arm and check the outside cam The cam switch arm should be in the down position flat part of cam 6 Turn power off and let door close completely Check inside cam The switch should be in the down position flat part of...

Страница 4: ... 4 ...

Страница 5: ...or system in compliance with the industry standards for safety It is your responsibility as owner or caretaker of the equipment to inspect the operation of your door system on a daily basis and after any loss of electrical power to ensure that it is safe for use by your invitees customers or employees Daily Safety Checks are the responsibility of the equipment owner or caretaker The Following safe...

Страница 6: ... shall not apply to such products which have been altered or repaired by other than an authorized agent Authorization shall be in writing by Quad Systems LLC Warranty does not apply if products have been subject to misuse negligence or accident There is no expressed or implied warranty by Quad Systems LLC except as specifically stated above Quad Systems LLC shall not be liable for special or conse...

Страница 7: ... 7 ...

Страница 8: ... 8 ...

Страница 9: ...operates 120 volt electrical supply supplied by others in accordance with all local codes This unit must be grounded Do NOT connect opener to source of power until instructed to do so Step One Mounting the Header Make sure the mounting area has proper support for the unit Wood studs or blocking in wallboard is recommended On each side of the door frame the header should overlap by 1 on each side I...

Страница 10: ... in or serious damage could be inflicted on the Controller as well as the installer Install the Hold Open Automatic HOA switch into the end cap hole provided on each end and plug in wiring harness from switch and operator into marked pins WARNING Do NOT connect opener to source of power until instructed to do so NOTE At this point do not install any other device into the controller i e switch harn...

Страница 11: ... 11 Installing Power Arm and Rod Prepare Power Arm and Rod as per drawings and charts ...

Страница 12: ... 12 ...

Страница 13: ...devices will be wired in a later step If a lock is present temporarily disable it to keep it from jamming the door while setting up the operator 2 0 Initial Setup WARNING In the next step you will be applying power to the operator in order to install the operator arm Avoid all moving parts Turn the unit on and set the on off hold switch to the Hold position Physically inspect the operator to ensur...

Страница 14: ...n off hold switch to the Hold position and let the door fully open Physically inspect the open check switch switch with orange and yellow wires and its associated cam The switch arm should be on the CENTER flat side of the cam The arm of the open check switch should remain depressed until the door is approximately 30 from the full open position and then it must release Do not proceed further until...

Страница 15: ...eeps open following an obstruction response timeout Note If the LIMIT adjustment is turned up too far it may not be possible to get the obstruction response 1 5 Actuating Accessory Wiring Remove power from the control Wire the actuating device s to ACT connector CN2 as shown in the wiring diagram Note that total accessory device current draw should be limited to 0 5A or less A radio receiver may b...

Страница 16: ...ired to keep the door from drifting closed after the display switches to HO SS Seek Speed Adjusts from 0 15 Default is 5 Should be adjusted to make the door creep open following the obstruction response see Section 1 4 AC ACceleration Determines how fast the door ramps up to open speed following an actuate command Possible values are 0 15 and the setup default is 15 maximum acceleration dC deccele...

Страница 17: ... speeds This reduces all open speed settings by approximately 50 allowing the use of very slow open speeds if desired Remaining speeds open check hold open etc are not affected by SL Default is off use normal open speeds LL Lock present When the LL parameter is on the control will trigger the lock relay prior to opening It will also attempt to unjam the door if requested see the UJ and UP paramete...

Страница 18: ...pening power will be somewhat higher with a door attached to the operator A conservative estimate would be a factor of roughly two times the given figure 0 82 amperes or 112 watts for any reasonable door weight up to 100 125 pounds The control has a 3 15 ampere fuse so in no case will the prolonged current draw be more than this figure as the fuse would blow Another question which seems to be aske...

Страница 19: ... 19 ...

Страница 20: ... 20 ...

Страница 21: ... 21 Lock with No Transformer not recommended Lock with Transformer recommended ...

Страница 22: ... 22 ...

Страница 23: ... 23 BEA Technical Support East Region 866 836 1863 West Region 888 419 2564 ...

Страница 24: ... 24 Optex Technical Support 800 966 7839 ...

Страница 25: ... 25 Optex Technical Support 800 966 7839 904C ...

Страница 26: ...lation instructions Q How do I easily adjust the cams A Place switch on Hold Open position and let the door open to the full open position Loosen the small Allen head screws on the outside cam switch with 2 wires Rotate the cam until the switch is on the flat part of the cam and tighten screw Place switch in the Off o position and let the door close completely Loosen the small Allen head screws on...

Страница 27: ...ontrol in a high energy mode this feature is supported beginning in Versions 1 02 1 03 An auxiliary harness Close Monitor harness part number 600 0008 01 will be required Set the AF parameter to 3 Wire the safety beam s output contact to the red and black wires of the auxiliary harness A beam break will prevent the door from opening if it s closed prevent it from closing if it s open slow the door...

Страница 28: ... 28 ...

Отзывы: