- 14 -
Important
: Be sure to save any changes you make before leaving the jobsite!
Changes are not
stored in the ES500 control’s permanent memory until you save them.
To save your
parameters, with the door in normal operation, press
and hold
the
SET
button until the display
winks
dS
(data Saved). Your parameters are now stored in the contr
ol’s permanent memory.
WARNING
: The
LIMIT, OBST, CLS
SPD, and
LAT SPD
screwdriver adjustments are in close
proximity to electrically hot parts. Be careful to avoid contact with any parts while making
adjustments.
1.3 Closing Adjustments
After the arm is installed, turn the
on/off/hold
switch to the
“Off”
position. The door will close.
Physically inspect the latch check switch (switch with the blue, gray, and white wires) and its
associated cam. The switch arm should be on the CENTER flat side of the cam. (
The arm of the
latch check switch should remain depressed from the full open position until the door is
approximately 10-15° from the full closed position, and then it must release.)
Adjust the cam
as necessary. Next, adjust the
CLS SPD
(close speed) and
LAT SPD
(latch speed) pots for the
desired closing operation.
DO NOT ADJUST WHEN THE DOOR IN IN MOTION
. The door may be
manually opened as many times as necessary to complete these adjustments.
1.4 Opening Adjustments
Turn the
on/off/hold
switch to the
“Hold”
position and let the door fully open. Physically inspect the
open check switch (switch with orange and yellow wires) and its associated cam. The switch arm
should be on the CENTER flat side of the cam. (
The arm of the open check switch should
remain depressed until the door is approximately 30° from the full open position, and then it
must release.)
Do not proceed further until you have verified the adjustment of this cam.
Temporarily set both the
LIMIT
pot and the
OBST
pot fully counterclockwise. Insure that the
on/off/hold
switch is in the
ON
position.
If the display is upside down, unplug the unit, press
and hold
the
bottom
button while plugging the
power connector back into
CN9
on the control until it lights up, then release. This will flip the display.
HINT
: If the door remains closed but the display does not switch to
Id
, insure that the latch check
cam has been adjusted properly (Section 1.3, Closing Adjustments) and that the rocker switch is in
the
ON
position. If the door tries to open, insure that the rocker switch is not in the
HOLD
position
instead of the
ON
position.
Cycle the door by pressing and holding the
DOWN
button (this button functions as an actuate signal
when the door is in normal operation, allowing easier testing). The door should cycle open. The
display will show
OS
(Open Speed) before the open check switch releases. It will switch to
OC
(Open Check) in the open check zone. If the
DOWN
button is held long enough, the display will
switch to
HO
(Hold Open).
Содержание EZ-7000
Страница 2: ... 2 ...
Страница 4: ... 4 ...
Страница 7: ... 7 ...
Страница 8: ... 8 ...
Страница 11: ... 11 Installing Power Arm and Rod Prepare Power Arm and Rod as per drawings and charts ...
Страница 12: ... 12 ...
Страница 19: ... 19 ...
Страница 20: ... 20 ...
Страница 21: ... 21 Lock with No Transformer not recommended Lock with Transformer recommended ...
Страница 22: ... 22 ...
Страница 23: ... 23 BEA Technical Support East Region 866 836 1863 West Region 888 419 2564 ...
Страница 24: ... 24 Optex Technical Support 800 966 7839 ...
Страница 25: ... 25 Optex Technical Support 800 966 7839 904C ...
Страница 28: ... 28 ...