FROM
AMPLIFIER
TO NEXT
SPEAKER
11
WIRING & CONNECTIONS
Ensure that all wiring is installed in compliance with local laws,
codes and convention. Obtain all necessary permits and approv-
als and use only cable that is approved for the application and is
sized to safely accommodate the load.
Models C / CT / C6 / C8 and CSUB
These models include two internal crossover networks allowing
either 4
Ω
or 16
Ω
low impedance operation. In addition they
include 70/100V transformers for use in distributed systems.
For 70/100V operation select the
appropriate wattage tap using the
rotary selector switch. Note that one
side of the switch is labeled for 70V
operation and the other side for 100V
systems. Ensure that the power is set
for the correct amplifier connected.
NOTE:
DO NOT USE THE
“0”
SETTING WHEN CONNECTED TO A 100V SOURCE!
Select the power tap by dividing the amplifier’s available power
by the number of speakers to be connected and then selecting the
next lower wattage tap. For example:
300W amplifier ÷ 20 speakers = 15 Watts; use the
15W terminal
Individual speakers may be tapped higher or lower in order to
better balance the system sound pressure level in different areas.
Ensure that the combined power draw does not exceed the rated
power of the amplifier or else damage to the amplifier and speak-
ers may occur. All 70/100V speakers should be wired in parallel
as shown to the right.