Qtx smartLIGHT SL-H7 Скачать руководство пользователя страница 3

 

154.020UK, 154.021UK User Manual

 

 

Setting up 

 

Install the SL-H7 or SL-H12 by using the mounting bracket on trussing or as a floor stand.  
Experiment with positioning and distance to get the best coverage for the area to be lighted. 

For DMX or master/slave control, link DMX out to DMX in using good quality DMX leads. 
Connect to mains using the appropriate IEC lead, checking that the supply voltage is correct. 

If an SL-FC4 controller is to be used, connect this via the 8P8C (RJ45) connector. 
 

Connection panel 

 

 
 

 
 

 
 

 
 

 

 
Control panel 

 

SL-H7 and SL-H12 fixtures can be operated in static, auto, sound activated or DMX modes. 

 
Depending upon which mode of operation is required, it will be necessary to select 

options and settings via the control panel and display.  
To set the operating mode, press FUNC, then UP or DOWN through options, then 

ENTER to select an option. 
 

Control panel settings 

 

Display 

Mode 

Press ENTER for setting (press FUNC to exit) 



DMX address 



 

to 





Auto program 1-4 



 

to

 



 (auto programs 1-4) 



Sound activated mode 



,

 



,

 



,

 



 (sound activated programs) 



Static colour 







  … 



  (15 selectable static colours)

 



Invert display 



 or 



 (inverted or non-inverted display) 

 
Standalone operation 

 

Static colour output is selectable via the

 



 option on the control panel. 

15 pre-set colours are available, detailed in the table on the following page. 
If a more dynamic effect is needed, 4 



 programs can be selected. 

These have a pre-set sequence, also detailed in the table on the following page. 



 sound activated options are also available responding to the internal microphone. 

 

Master/Slave operation 

 
For Auto, Sound or Colour modes, Master/Slave mode can be enabled by connecting onto further SL-H7 or 

SL-H12 units using XLR leads and setting all slave units to any DMX address. 

 

1. 

DMX in XLR 

2. 

DMX out XLR 

3. 

SL-FC4 connector RJ45 

4. 

Sound activation microphone 

5. 

Microphone sensitivity control 

6. 

IEC mains output (SL-H12 only) 

7. 

Mains inlet IEC and fuse holder 