150.471UK User Manual
101~110
#2 & #6
111~120
#3 & #7
121~130
#4 & #8
131~140
#1 & #2
141~150
#3 & #4
151~160
#5 & #6
CH5 cont.
161~170
#7 & #8
White LED’s
171~180
#1 & #8
181~190
#4 & #5
191~200
#1 #3 #5 & #7
201~210
#2 #4 #6 & #8
211~220
#3 #4 #5 & #6
221~230
#1 #2 #7 & #8
231~240
#1 #2 #3 & #4
241~250
#5 #6 #7 & #8
251~255
All on
CH6 Strobe
11~255
Strobe from slow to fast
11~200
Auto DMX
CH7
201~255
Sound DMX
CH8
0~255
Auto DMX/ Sound DMX Speed (Slow--Fast)
Troubleshooting
Check mains voltage is correct and outlet is switched on
No power (mains)
Check IEC lead and fuse (if fuse continually blows, refer to your
dealer)
Check laser safety key lock is turned to the On position
No laser output
Switched safety key lock off and on again to reactivate laser function
if it has been previously deactivate via remote socket
No LED display
Press any control panel button and check LED setting in menu
Check control panel mode settings (standby, slave, sensitivity, DMX)
No light output
Check DMX settings from controller (dimmer levels, blackout etc.)
No strobe output
Check strobe settings on control panel or from DMX controller
Check DMX connection and leads
Unresponsive to DMX
Check that DMX mode is enabled (set “Addr” on control panel)
Overheating/
cutting out
Ensure that the unit is not too close to a heat source