Offset
Description
8
Reserved
9
Reserved
The units for the times are 0.1 milliseconds. A value of 87 means 8.7 ms.
To map the statistics for a given connection, include a line with the keyword ConnStatsn,
where n is the connection number, from 0 to 15, in the input section of a connection.
If you omit the offset, the line must start with a comma.
Examples:
,ConnStats2
40, ConnStats2 ; offset 40
To clear the connection statistics, set bit 0 in word 0 of the output data for connection 15.
This clears the diagnostic counters and the connection statistics.
You can also clear the diagnostic counters and connection statistics separately from the
web interface.
Sending and Retrieving ControlLogix Configurations
To transfer a ControlLogix configuration file to the AN-X2-MOD-MON, first select
Automation Network/ControlLogix Support
in the web interface.
Click the
Browse
button, select the file, then click the
Send to AN-X
button to transfer the
configuration.
To transfer a configuration from the AN-X2-MOD-MON, first select
Automation
Network/View Configuration Files
in the web interface.
Right click on
AN-X2-MOD-MON ControlLogix Configuration File
and select
save link
as
and save the file on your computer.
Sample Ethernet Configuration File
The following is a file generated by AN-X during an autoconfiguration.
;QTS AN-X2-MOD-MON Auto Configuration Utility
;Copyright (c) 2005 Quest Technical Solutions
;Auto Config Ethernet/IP File - Version 4.2.4
ClxName,AnxModMon
ClxPrefix,MOD_
ClxPrefixOut,MOD_MONOUT_
; ---- Modicon Inputs ----