background image

4.  General information

4. General information

4.1  About this manual

Manual code:

 DCMIINE0QIR100H

Revision:

 100

Copyright:

The information contained in this document is the sole property of Inim Electronics S.r.l.. Copy-

ing, reprinting or modification of this document, in part or as a whole, is not permitted without prior autho-

rization in writing from Inim Electronics S.r.l.. All rights reserved.

4.2  Manufacturer's details

Manufacturer:

 Inim Electronics S.r.l.

Production plant:

 Centobuchi, via Dei Lavoratori 10

63076 Monteprandone (AP), Italy

Tel.:

 +39 0735 705007

Fax:

 +39 0735 734912

E-mail

 [email protected]

Web:

 www.inim.biz

The persons authorized by the manufacturer to repair or replace the parts of this system have authorization 

to work only on devices marketed under the brand Inim Electronics.

4.3  Warranty

Inim Electronics S.r.l.. (Seller, Our, Us) warrants the original purchaser that this product shall be free from 

defects in materials and workmanship under normal use for a period of 24 months.
As Inim Electronics does not install this product directly, and due to the possibility that it may be used with 

other equipment not approved by Us;Inim Electronics does not warrant against loss of quality, degradation 

of performance of this product or actual damage that results from the use of products, parts or other repla-

ceable items (such as consumables) that are neither made nor recommended by Inim Electronics. Seller 

obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any 

product not meeting the specifications. In no event shall Inim Electronics be liable to the purchaser or any 

other person for any loss or damage whether direct of indirect or consequential or incidental, including 

without limitation, any damages for lost profits, stolen goods, or claims by any other party caused by defec-

tive products or otherwise arising from the incorrect or otherwise improper installation or use of this product.
This warranty applies only to defects in parts and workmanship relating to normal use. It does not cover 

damage arising from improper maintenance or negligence, damage caused by fire, flood, wind or lightning, 

vandalism, fair wear and tear.
Inim Electronics S.r.l. shall, at its option, repair or replace any defective products. Improper use, that is, use 

for purposes other than those mentioned in this manual will void the warranty. Contact Our authorized dea-

ler, or visit our website for further information regarding this warranty.

14

Installation and programming manual- 100

Содержание XLINE Series

Страница 1: ...QIR100H Indoor passive infrared detector for intrusion alarm systems Installation and programming manual EN 50131 1 EN 50131 2 2 EN 50130 4 EN 50130 5 CEB T031 100 235...

Страница 2: ...2 3 Balancing 9 2 3 1 N C N O 9 2 3 2 Single balancing 10 2 3 3 Double balancing 10 2 3 4 Double zone balancing 10 2 3 5 Double zone balancing with EOL 11 3 Programming 12 3 1 Programming from QIR100H...

Страница 3: ...status and the yellow LED turns off During the 60 second self calibration phase the partition monitored by the detector must be in stand by status free from obstacles and people moving about The alarm...

Страница 4: ...ng LED C Lens D Base E Cover retainer locations F Cable entry G Mounting screw locations H Cover securing screws I PCB securing screws J Terminal board K Anti opening tamper L Button P1 M Button P2 N...

Страница 5: ...om 10 to 16 V nominal 12 6 V Stand by current draw 11mA 12 6V Maximum current draw 13mA 12 6V Detectors type digital dual PIR Detection mode Infrared emission Alarm pulses from 1 to 2 Intrusion alarm...

Страница 6: ...the base to the chosen mounting placement and mark the screw holes position 5 Using the screws secure the base in position 6 Complete the connections on the terminal board 7 If necessary carry out th...

Страница 7: ...ot install the detector in locations where there is risk of rapid temperature changes l Do not blind the field of detection of the sensor even partially l The detector should be mounted with the alarm...

Страница 8: ...2 Installation Top view 12 10 8 6 4 2 0 2 4 6 8 10 12 0 2 4 6 8 10 12 14 16 90 IR level 1 IR level 2 IR level 3 8 Installation and programming manual 100...

Страница 9: ...respective balancing method depend on the type of detector you are installing and the level of protection you wish to achieve The detectors can be powered through l terminals AUX 12V and GND on the c...

Страница 10: ...l 2 3 3 Double balancing Double balancing discriminates 4 distinct conditions on the zone terminal l stand by l alarm l tamper short circuit l tamper wire cutting 6K8 6K8 Tx 2 3 4 Double zone balancin...

Страница 11: ...cing with EOL Double zones with EOL resistors can discriminate 6 conditions on the entire terminal l stand by on both zones l alarm on zone 1 and standby on zone 2 l alarm on zone 2 and stand by on zo...

Страница 12: ...ave the first option active 4 Use the P1 button to move to the different options on the menu see The LED combination the LEDs which blink identifies the option concerned 5 By pressing the P2 button it...

Страница 13: ...er on the menu The Options column shows the value of the programmable settings for each parameter The boxes with a grey background indicate the values of the factory parameters functions Menu P1 butto...

Страница 14: ...ant against loss of quality degradation of performance of this product or actual damage that results from the use of products parts or other repla ceable items such as consumables that are neither mad...

Страница 15: ...of electrical and electronic equipment applicable in countries with differentiated waste collection systems The crossed out bin symbol on the equipment or on its packaging indicates that the product...

Страница 16: ...n web site for full warranty details Innovative Electronic Solutions www ness com au QLD Ph 07 3399 4910 WA Ph 08 9328 2511 NSW Ph 02 8825 9222 sales ness com au VIC Ph 03 9875 6400 nessmelb ness com...

Отзывы: