Please read these instructions carefully 

before using the equipment 

 

 

GENERAL SAFETY

 

WARNING!  

Read and understand all instructions. Failure to follow all instructions listed 

 

below may result in electric shock, fire and / or serious personal injury. The term 

airless 

sprayer 

in all of the warnings listed below refers to your 

mains

-

operated (corded) airless 

sprayer

.

 

 

WORK AREA

 

+  

 

Keep your work area clean and well lit. Cluttered benches and dark areas 

 

 

invite accidents.

 

+  

 

Do not operate airless sprayers in explosive atmospheres, such as in the 

 

 

presence of flammable liquid, gases, or dust. Airless sprayers create sparks 

 

 

which may ignite the dust or fumes.

 

+  

 

Keep bystanders, children, and visitors away while operating a airless sprayer. 

 

Distractions can cause you to lose control.

 

 

 

6

 

QTech 

QT290 Airless Sprayer

 

ELECTRICAL SAFETY

 

+  

 

Airless sprayer plugs must match the outlet. Never modify the plug in any 

 

 

way. Do not use any adapter plugs with earthed (grounded) airless sprayers. 

 

Unmodified plugs and matching outlets will reduce the risk of electric shock.

 

 

Grounded sprayers must be plugged into an outlet properly installed and 

 

grounded in accordance with all codes and ordinances. Never remove the 

 

grounding prong or modify the plug in any way. Do not use any adaptor 

 

plugs. Check with a qualified electrician if you are in doubt as to whether the 

 

outlet is properly grounded. If the sprayer should electrically malfunction or 

 

break down, grounding provides a low resistance path to carry electricity 

 

away from the user.

 

+  

 

Avoid body contact with grounded surfaces such as pipes, radiators, ranges 

 

and refrigerators. There is an increased risk of electric shock if your body is 

 

earthed or grounded.

 

+  

 

Do not expose airless sprayers to rain or wet conditions. Water entering an 

 

airless sprayer will increase the risk of electric shock.

 

+  

 

Do not abuse the cord. Never use the cord for carrying, pulling or unplugging 

 

the airless sprayer. Keep the cord away from heat, oil, sharp edges or moving 

 

parts. Replace damaged cords immediately.

 

 

Damaged or entangled cords increase the risk of electric shock.

 

+  

 

When operating an airless sprayer outdoors, use an outdoor extension cord 

 

suitable for outdoor use. Use of a cord suitable for outdoor use reduces the 

 

risk of electric shock.

 

7

 

Brought to you by 

Aristospray

 

Содержание QT290

Страница 1: ...b Stephenstown Industrial Park Balbriggan County Dublin Ireland Australia 27 Tatura Avenue Gosford NSW 2250 Email sales aristospray com www Aristospray com www SprayForthedecorator com Phone UK 01895...

Страница 2: ...im gun at scrap and pull trigger to clear Check tip for wear replace where necessary Check all filters are clear of debris clean or replace Ensure OK for coating tip combination change if necessary Ch...

Страница 3: ...r 3000 psi SPECIFICATION Motor 1300 watt Weight 33 0 kg Warranty 2 years SUPPLIED COMPLETE WITH TriTech T360 airless spray gun TriTech Contractor 517 airless tip guard 1 4 x 15m textile braided hose a...

Страница 4: ...k Grounded sprayers must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances Never remove the grounding prong or modify the plug in any way Do not use...

Страница 5: ...n to relieve residual fluid pressure Hold metal part of the gun in contact with grounded metal pail 4 Turn the Priming Valve to the open priming position to relieve residual fluid pressure 5 Re engage...

Страница 6: ...NEVER allow another person to use sprayer unless he is thoroughly instructed on its safe use and given this operator s manual to read ALWAYS wear a spray mask gloves and protective eye wear while spr...

Страница 7: ...n result in serious bodily injury and property damage For detailed instructions on how to ground check your local electrical code ALWAYS ensure switch is in OFF position before plugging unit in Always...

Страница 8: ...ure that there is no pressure in the unit and close the prime pressure relief valve for storage 4 Start up after storage Before using water base paint flush with soapy water and then with clean water...

Страница 9: ...sure d Check the spray pattern The tip size and angle determines the pattern width and flow rate Spray a test pattern and then adjust the pressure to eliminate heavy edges Use a smaller tip size if th...

Страница 10: ...lter use a brush dipped in an appropriate solvent Change or clean filters at least once a day Some types of latex may require a filter change after about four hours of operation SPRAY TIP SELECTION Sp...

Страница 11: ...packings and reduce the packing life 20 QTech QT290 Airless Sprayer PACKINGS The packings are a wearing part If the pump can no longer maintain pressure has difficulty priming and paint seeps into th...

Страница 12: ...8 12 290 010 PUMP HOUSING 1 09 12 003 OUTPUT NIPPLE PT 1 4 x 1 4 19PF 1 10 12 290 011 RETAINING NUT 1 11 12 002 COMPLETE PACKING KIT INC PARTS 05 06 11 14 16 19 20 1 12 12 008 PACKING SPACER 1 13 12 0...

Страница 13: ...2 290 069 SOCKET CAP SCREW M5x55xP0 8 4 Brought to you by Aristospray 25 Control Box ITEM PRODUCT CODE DESCRIPTION QTY 70 1 12 290 091 1 ELECTRONICS UNIT 110V 1 70 2 12 290 091 2 ELECTRONICS UNIT 220V...

Страница 14: ...UT NIPPLE PT 1 4 x 1 4 19PF 2 107 12 290 071 FILTER HOUSING 1 108 12 290 075 PRIMING VALVE 1 109 12 016 DRAIN TUBE PT1 8 x0 45M 1 110 12 290 078 SOCKET SET SCREW PT1 4 1 111 12 290 079 HEX NUT M5 P0 8...

Отзывы: