1. Grounding Stud
2. Power Supply Module Slot 1 (A filler panel is required if the slot is vacant.)
3. Power Supply Module Slot 2 (A filler panel is required if the slot is vacant.)
1.5.3. Power Supply
The QSW-4700-52TX-POE switch supports dual power supply modules. See Chapter 1.13 for
details about the power supply modules.
The switch can be powered on by either one power supply module or dual power supply modules.
If both power supply modules are used, the switch works in the power redundancy mode.
1.5.4. Cooling
The QSW-4700-52TX-POE switch adopts a left-to-right and front-to-right airflow to ensure normal
operation. Maintain a minimum clearance of 100 mm (3.94 in.) around the device for air
circulation.
Figure 1-16 Airflow Direction
1.5.5. LED
Function
Panel ID
Color
Status
System Status LED
Status
Off
System is not powered on.
Blinking
Green (3
Hz)
System is being initialized.
Continuous blinking indicates a
fault.
Blinking
Green (10
Hz)
System is being located.
Solid
Green
System is operating normally.
Solid
Yellow
The temperature at the air intake
and exhaust vents exceeds the
threshold.