3b: Analog Programming
PART OF RESETING AND WORKING WITH THIS UNIT IN ANALOG MODE IS THROUGH A
MAGNETIC REED SWITCH WHICH IS AN OPTIONAL PART. IF YOU FEEL YOU NEED THIS PART PLEASE NOTIFY YOUR DEALER.
There is another simple option. Solder two wires to the reed switch pads and touch them together momentarily to
simulate the reed switch function, see Pg-7.
Your locomotive can be programmed using a standard power pack.
All advanced operations are easily programmed using your standard HO power pack. After entering
programming (described below), the various features are selected and operated by using the direction switch.
Program
Option
#'s (POP's)
Option Name
(Default Value)
Message When
Entering Option
Option Description
1
System Volume
(16, Max)
“Volume equals X”
Sets System volume (17 level) where level 16 is
max and level 0 is off.
2
Load
(0, No Load)
“Load equals X”
Selects the starting and stopping inertia for both Regulated
Throttle Control (RTC) and
Standard Throttle Control (STC). Level 0 (no load), Level 1-
15, increasing Load with
acceleration to full speed from 15 seconds to 210 seconds
in RTC and from 3 seconds
to 45 seconds in STC.
3
Helper
(Normal)
“Helper Equals”
“Normal”
“Lead”
“Mid”
“End”
“Pusher”
Selects Normal, Lead, Mid, End, or Pusher Helper in
consists.
Normal Locomotive has all sounds and lights enabled.
Lead locomotive has all sounds enabled and Reverse Light
disabled.
Mid Helper has Horn, Bell and all lights disabled11.
End Helper has Horn, Bell and all lights disabled except
Reverse Light.
Pusher has Reverse Light on all the time as train warning
light. Horn, Bell and all other
lights are disabled.
4
Directional
(Normal)
“Direction Equals
X”
Selects if the features associated with the locomotive’s
direction are “Normal” or“Reversed”.
5-7
Reserved
“Reserved”
8
V-Start (8.5v)
“V-Start Equals X”
Sets track voltage at which locomotive will leave Neutral.
(See Example below)
9
V-Max (12v)
“V-Max Equals X”
Sets track voltage at which full track power is applied to motor.
10
Throttle Mode
(RTC)
“Mode Equals X”
Selects between Regulated Throttle Control (RTC)
and Standard Throttle Control (STC)
11
Programming
Reset
“Warning-about to
reset”
Selects between Regulated Throttle Control (RTC) and
Standard Throttle Control (STC).
12
About
“Model Number”
Each Quick or Slow Operation provides progressive
information about Quantum Model Number, Software
Version, and Software Release Date.