background image

Quantum Engineer Operation Manual, Ver. 2.0.1  

7/24 

19 September 2006 

Locomotive Feature Keys 

 

  Load On/Off    

   

Once you enter the Load value into Programming Option #2 

(POP 2) and return to Run Mode, you can toggle this Load value on or off in 

Neutral  with  the

  Load  On/Off

  key.  When  Load  is  off,  the  locomotive  will 

accelerate or decelerate at its Intrinsic Inertia value.

  

Operation while in Neutral

  

 

Press the 

Load On/Off

 button once in Neutral to turn on the Load. You 

will hear a Long Air Let-off. 

 

Double-press the 

Load On/Off

 button in Neutral to turn off the Load. 

You will hear a coupler clink.  

Note:

 Labored sounds (Sound-of-Power

) are increased when Load is 

on and the locomotive is accelerating.  

Operation

 

while Moving

 

With 

RTC

10

 selected and the locomotive is moving in Forward or Reverse, 

pressing the 

Load On/Off

 button will apply or remove a “Heavy Load” to the 

locomotive.  This  represents  a  train  that  would  take  over  ten  to  fifteen 

minutes to accelerate to full speed or to coast to a complete stop. You can 

apply “Heavy Load” as soon as you start moving or wait until you are up to 

speed.  

 

Press the 

Load On/Off

 button once in Forward or Reverse to turn on 

Heavy Load

.

 Hear a single Horn or Whistle hoot.  

 

Double-press the 

Load On/Off

 button in Forward or Reverse to turn off 

Heavy Load

.

  Hear a double Horn or Whistle hoot.  

Note:

 Heavy Load does not require you to program any Load values in 

POP 2.  

Note:

 If you apply Air Brakes while in Heavy Load, the locomotive will 

return to operation using the programmed Load setting in POP 2.  

Note:

  Be  aware  that  once  Heavy  Load  is  turned  on,  the  throttle  will 

have  little  effect  in  changing  the  speed  of  the  train.  If  you  turn  the 

throttle up, you will hear very intense Sound of Power effects or if you 

turn the throttle down, you will hear very subdued Sound of Power

11

                                                

10

  Load On/Off has no effect under STC.  

11

  If you turn the throttle down too far, the train will slow quickly as the available power to the track falls below 

the level that is necessary for RTC to operate.  

Содержание Quantum Engineer

Страница 1: ...Quantum Engineer Add on Control System For Analog Operation of Quantum Systems with QARC Technology Version 2 0 1...

Страница 2: ...5 Locomotive Feature Keys 7 Automatic Features with Take Control Operation 11 Locomotive State Keys 14 Star Pad Keys During Normal Operation 17 PROGRAMMING WITH STAR PAD KEYS 19 Entering Program Mode...

Страница 3: ...impler The buttons on the right are the Primary Control Keys for locomotive operation and include horn bell and brakes The set of fifteen gray keys to the left of the Primary Control Keys are the Loco...

Страница 4: ...motive The only exceptions are the Start Up and Shut Down keys where a double press produces an extended Start Up or extended Shut Down sound effect Installation Wire the Quantum Engineer to your powe...

Страница 5: ...l information on Doppler and special Horn Endings Pressing and releasing the Bell key will toggle the locomotive s Bell effect on or off Apply Brakes and Release Brakes You can apply brake effects wit...

Страница 6: ...otive has an active Load value see Load On Off on page 7 Note You will only need to press the Apply Brakes key once after the locomotive has stopped to return to original speed7 Note If the locomotive...

Страница 7: ...d take over ten to fifteen minutes to accelerate to full speed or to coast to a complete stop You can apply Heavy Load as soon as you start moving or wait until you are up to speed Press the Load On O...

Страница 8: ...ng will reduce to a low level and return to its previous setting when Dynamic Brakes are shut off This makes steam locomotive behavior similar12 to diesels in a consist Note In contrast to Air Brakes...

Страница 9: ...ing the Horn key16 and hear the normal Horn or Whistle While still pressing the Horn key press and release the Doppler key to hear the Doppler shift A few seconds after the Horn key is finally release...

Страница 10: ...coupling pin being raised This also Arms the uncoupling sound effect Press the Coupler Sounds key again while pulling away from the cars or remaining stationary in Neutral to trigger the sound of the...

Страница 11: ...ower Fans Turns the Blower hiss sounds on or off Diesel Vents Cooling Fans Non operating Non operating On and off at random times Blower Fans Turns the Cooling Fans on or off Number Board Lights On On...

Страница 12: ...Double press the Number Boards key to turn off and take control of the Number Board Lights Headlight Press the Headlight key once to turn on and take control of the Headlight The Headlight will be on...

Страница 13: ...part of the automatic lighting system Overhead Blinking Lights are on in all directional states Strobe Hazard Hazard Lights can either be steadily on or strobing The Mars Light strobe gives the effect...

Страница 14: ...r can increase the throttle on a stationary locomotive to rev the Diesel Motor or vent steam in a steam engine Standby places the locomotive in a special idle state with subdued sounds where it will n...

Страница 15: ...pplied for the next operating session Press the Shut Down key once to produce a Rapid Shut Down Rapid Shut Down will shut the locomotive off in a few seconds Double press the Shut Down key to produce...

Страница 16: ...normal operation by pressing the Start Up key Start Up will be different for each stage of Shut Down but all will start up with a Long Air Let off and will enter normal operation Start Up from Discon...

Страница 17: ...s the Status key when locomotive is stopped in Neutral If the locomotive is in Disconnect Standby Shut Down it will say so Otherwise the locomotive s Helper type if not Normal will be announced follow...

Страница 18: ...sounds to its normal level Note Mute state is not maintained if power is turned off and back on the locomotive will return to full System Volume setting STC and RTC Use these keys in Neutral to select...

Страница 19: ...e you have entered Programming Mode the Prgm key has no effect Note When in Programming Mode the red power light on the Quantum Engineer blinks on and off Note In Programming Mode the locomotive s Dir...

Страница 20: ...lume equals X where X is its current volume level setting After a moment you will hear the sound playing at its current volume24 After the announcement of the current value press the Volume or the Vol...

Страница 21: ...ough their procedures one step at a time when either the Volume or Volume key is pressed Note Press the Next or the Prev keys any time to move to the next or previous POP Or press and hold the Next or...

Страница 22: ...s but will not respond to the throttle You may have applied brakes to stop your locomotive Either reduce the throttle below V Start or press the Release Brake key two times Or your locomotive is in Di...

Страница 23: ...onstant high speed for some time before it starts to slow down Some operators will apply more and more braking to slow the engine which causes the locomotive to slow rapidly when the internal voltage...

Страница 24: ...l property rights to the Quantum Engineer Software Firmware Hardware or Artwork Design The use of any trademarks as herein authorized does not give you any rights of ownership in that trademark 2006 A...

Отзывы: