Utility/Diagnostic Functions (continued)

RS-232 Communications Procedure:

1)

 Connect the 

RS-232

 port of the RAVE 522ua to an unused serial port (COM port) of a PC using a normal (straight-through) serial 

cable. 

2)

 Open the 

HyperTerminal 

program. This program is usually started by clicking the Windows 

Start

 icon, selecting 

Programs

, then 

Accessories

Communications

, and finally, highlighting the

 Hyper Terminal 

folder and clicking on its icon.

3)

 After starting 

Hyper Terminal

,

 a 

Connection Description 

window will pop-up. It will require that you name your connection. 

Enter a name for your new connection (example: 

RAVE 522ua

) and click

 

OK 

to continue.

4)

 Next, 

Hyper Terminal

 needs to know how to “talk” to the RAVE 522ua. This selection depends on which port on your PC the cable 

is connected to. Ignore the first three entry fields (phone number information) and go directly to the 

Connect using 

entry field and click 

on the down arrow for the drop-down menu selection. Select the port the RAVE 522ua is connected to and click 

OK

 to continue. The 

Properties 

window should appear next.

5) 

The 

Properties 

window for the selected 

COM 

port should now be active. For the Port Settings, use the following information so 

communication between the RAVE 522ua and the computer is in the same “language”.

Bits per Second: 

9600

Data Bits

: 8

Parity

: none

Stop Bits: 

1

Flow Control: 

Xon/Xoff

Once you have set the properties as outlined, click 

OK

 to continue. If all the connections and communications settings are correct, the 

main 

Hyper Terminal

 window will open.

6) 

The

 

Hyper Terminal

 

main window will appear next, but blank. Type the letter “h” (for help) and then the “Enter” key. This will 

prompt the RAVE 522ua to post its menu text. The “h” key is the Help prompt for the RAVE 522ua. A text menu will appear. This is sent 
by the RAVE 522ua and will detail your options and instructions for changing the address information. 

From this main-menu you will need to make your menu choices and follow the instructions in the following sub-menus or screens. 
Although many of the instructions and tests may not pertain to a specific setup or troubleshooting situation, you may be asked to run 
certain tests by a QSC technical representative. The results of these tests will help to troubleshoot any problems.

The most common user item that might require settings to be changed would be the IP address information. This would be useful if the 
IP address was inadvertently changed to an unrecognized address and subsequently you were unable to “talk” to the RAVE 522ua over 
the network. This situation would require the 

Display Network Settings

 and 

Enter Network Setup

 items to be accessed for re-

assigning a valid IP address.

IP ADDRESS ASSIGNMENT- ONLY REQUIRED FOR ATTACHING TO EXISTING NETWORKS! DO NOT CHANGE THE COM-
MUNICATIONS SETTINGS OF THE RAVE 522ua UNLESS CERTAIN OF YOUR ACTIONS. THE FACTORY-PROGRAMMED IP 
ADDRESS CAN BE ACCESSED USING THE FRONT PANEL DISPLAY MENU SYSTEM. RECORD THIS IP ADDRESS SHOULD 
YOU NEED TO RETURN TO THE INITIAL SETTINGS.

Содержание RAVE 522ua

Страница 1: ...TD 000198 00 rev A TD 000198 00 RAVE 522ua 8x8 CobraNet Enabled Signal Processor Hardware Manual...

Страница 2: ...ord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE S...

Страница 3: ...at the same time from anywhere a connection to the QSControl net network is available The QSControl net network can also be managed from a sin gle computer running both the client and the server Once...

Страница 4: ...will be adding new capabilities to both RAVE and QSControl net Our latest code releases and access to up to date information on RAVE and QSCon trol net are available at www qscontrol net We invite yo...

Страница 5: ...er rules To learn more about CobraNet and appropriate network topologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background html Notes on...

Страница 6: ...is a TCP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl net segment does not r...

Страница 7: ...out a network switch However you would have to physically connect your computer first to one unit and then to the other With this elementary connection you don t have a true network It is like making...

Страница 8: ...figuration works well when CobraNet audio deliveries are point to point Though the example shows only two RAVE BASIS units as many devices may be connected as there are available switch ports All unit...

Страница 9: ...VLAN for QSControl net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for QSControl net including the system controller and a secon...

Страница 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Страница 11: ...pment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mounting Rack moun...

Страница 12: ...ystem is used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Panel features be disabled Display hard drive system st...

Страница 13: ...ily mute allow ing the RAVE 522ua to synchronize with its internal clock If CobraNet network connection is re established the audio will mute again while the RAVE 522ua synchronizes with CobraNet Conf...

Страница 14: ...Use balanced audio inputs whenever possible Each input has software selectable 48V phantom power Use caution when connecting equipment par ticulary unbalanced equipment Analog Outputs Eight balanced...

Страница 15: ...unctioning AC outlet it will power up and briefly display a welcome screen on the LCD dis play POWER Indicator This blue indicator illuminates when the RAVE 522ua is plugged into a properly functionin...

Страница 16: ...ept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accepting choices entering by pushing in on the control The accessible menus and sub menu...

Страница 17: ...creen accessed becomes the new power up default Boot Screen Right side buttons serve as up down navigation Arrow characters indicate right side button context If additional menus are available the arr...

Страница 18: ...cify the installation directory or accept the default location 9 You will be prompted to select an installation accessible by everyone non secure or an installation accessible only to you secure Selec...

Страница 19: ...verify IP addresses are set correctly verify Subnet masks are set correctly and verify AC power is properly applied to the RAVE 19 Click on the sign of the RAVE 522ua in the inventory root then the si...

Страница 20: ...ork This is currently 16 bit 20 bit and 24 bit Audio via inbound bundles may be in any combination of these resolu tions and the RAVE will process the data accordingly All DACs will process 24 bit aud...

Страница 21: ...icate with the RAVE 522ua if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port in...

Страница 22: ...click OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the letter...

Страница 23: ...opening a Telnet session 1 To open the Telnet session Click START select RUN type Telnet followed by a space then the IP address of the RAVE 522ua you want to communicate with in the text box and cli...

Страница 24: ...put Sensitivities variable Vrms 0 9 mV to 15 46 V dBu 62 2 to 26dBu dBV 64 4 to 23 7 dBV Phantom Power per IEC 1938 1996 48V software selectable Program Outputs 8 Connector Type 3 pin Phoenix Style a...

Страница 25: ...nd referenced Pinout 1 Signal 2 CHASSIS GND Normal Operating Range Reads signals between 0 5V nominally Potentiometer Operation Use 10K for full range Voltage Tolerance 48V Current Output 0 5mA with 1...

Страница 26: ...26 Dimensions...

Страница 27: ......

Страница 28: ...suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products with...

Отзывы: