Relay Out

Two sets of relay contacts are provided, RELAY OUT 1 and RELAY OUT 
2. Contacts are floating and rated for 30VDC, 1A. There is one common 
terminal, one normally-closed contact terminal and one normally-open 
contact terminal. These are labeled as 

C, NC

 and 

NO

 on the rear panel. 

When the relay is not energized, the 

C

 terminal is connected to the 

NC

 

terminal and the 

NO

 terminal is not connected; when the relay is ener-

gized the 

C

 to 

NC

 connection is opened and the 

to 

NO

 connection is 

closed. 

RS-232

The RS-232 is a utility serial port for accessing certain diagnostic fea-
tures and setup. Connect to an available COM port on your PC and com-
municate using a terminal control program such as Windows 
Hyperterminal.

Use a normal serial data cable with a DB-9 male plug to connect to the 
RAVE 522ua. To connect the cable, orient the connector properly, then 
push into the receptacle until it is firmly seated; tighten the retaining 
screws “finger tight”. Communications should be 9600 baud, no parity, 
8 data bits, 1 stop bit, and flow control Xon/Xoff.

LED Indicators

When the RAVE 522ua is plugged into a properly functioning AC outlet, 
it will power up and briefly display a welcome screen on the LCD dis-
play.

POWER Indicator- 

This blue indicator illuminates when the RAVE 

522ua is plugged into a properly functioning AC source. There is no 
power switch on the RAVE 522ua. This helps to prevent accidental sys-
tem shutdowns.

DIAGNOSTIC Indicator- 

This red diagnostic LED reports several pos-

sible operational conditions. During boot-up, it is used to continually 
blink a “dot-dash” pattern if the power-on memory self-test fails. Dur-
ing normal operation, if any non-recoverable system fault occurs, the 
diagnostic indicator will remain on, requiring a power restart. If this 
condition persists, contact QSC’s Technical Services for assistance.

The diagnostic LED is also used to indicate an update is in progress 
during a remote firmware update cycle. First, the LED will blink slowly, 
indicating the memory erase cycle, then it will blink rapidly, indicating 
the memory write cycle. 

NOTE! During a firmware update, it is 

critical the unit remain powered on for the entire process in 
order to complete successfully.

The diagnostic LED may also be controlled by using the QSControl.net 
software. This feature is particularly helpful for identifying a particular 
unit.

(continued, next page)

Relay Out connections. 
Refer to text, at left, for 
explanation.

Содержание RAVE 522ua

Страница 1: ...TD 000198 00 rev A TD 000198 00 RAVE 522ua 8x8 CobraNet Enabled Signal Processor Hardware Manual...

Страница 2: ...ord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE S...

Страница 3: ...at the same time from anywhere a connection to the QSControl net network is available The QSControl net network can also be managed from a sin gle computer running both the client and the server Once...

Страница 4: ...will be adding new capabilities to both RAVE and QSControl net Our latest code releases and access to up to date information on RAVE and QSCon trol net are available at www qscontrol net We invite yo...

Страница 5: ...er rules To learn more about CobraNet and appropriate network topologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background html Notes on...

Страница 6: ...is a TCP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl net segment does not r...

Страница 7: ...out a network switch However you would have to physically connect your computer first to one unit and then to the other With this elementary connection you don t have a true network It is like making...

Страница 8: ...figuration works well when CobraNet audio deliveries are point to point Though the example shows only two RAVE BASIS units as many devices may be connected as there are available switch ports All unit...

Страница 9: ...VLAN for QSControl net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for QSControl net including the system controller and a secon...

Страница 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Страница 11: ...pment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mounting Rack moun...

Страница 12: ...ystem is used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Panel features be disabled Display hard drive system st...

Страница 13: ...ily mute allow ing the RAVE 522ua to synchronize with its internal clock If CobraNet network connection is re established the audio will mute again while the RAVE 522ua synchronizes with CobraNet Conf...

Страница 14: ...Use balanced audio inputs whenever possible Each input has software selectable 48V phantom power Use caution when connecting equipment par ticulary unbalanced equipment Analog Outputs Eight balanced...

Страница 15: ...unctioning AC outlet it will power up and briefly display a welcome screen on the LCD dis play POWER Indicator This blue indicator illuminates when the RAVE 522ua is plugged into a properly functionin...

Страница 16: ...ept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accepting choices entering by pushing in on the control The accessible menus and sub menu...

Страница 17: ...creen accessed becomes the new power up default Boot Screen Right side buttons serve as up down navigation Arrow characters indicate right side button context If additional menus are available the arr...

Страница 18: ...cify the installation directory or accept the default location 9 You will be prompted to select an installation accessible by everyone non secure or an installation accessible only to you secure Selec...

Страница 19: ...verify IP addresses are set correctly verify Subnet masks are set correctly and verify AC power is properly applied to the RAVE 19 Click on the sign of the RAVE 522ua in the inventory root then the si...

Страница 20: ...ork This is currently 16 bit 20 bit and 24 bit Audio via inbound bundles may be in any combination of these resolu tions and the RAVE will process the data accordingly All DACs will process 24 bit aud...

Страница 21: ...icate with the RAVE 522ua if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port in...

Страница 22: ...click OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the letter...

Страница 23: ...opening a Telnet session 1 To open the Telnet session Click START select RUN type Telnet followed by a space then the IP address of the RAVE 522ua you want to communicate with in the text box and cli...

Страница 24: ...put Sensitivities variable Vrms 0 9 mV to 15 46 V dBu 62 2 to 26dBu dBV 64 4 to 23 7 dBV Phantom Power per IEC 1938 1996 48V software selectable Program Outputs 8 Connector Type 3 pin Phoenix Style a...

Страница 25: ...nd referenced Pinout 1 Signal 2 CHASSIS GND Normal Operating Range Reads signals between 0 5V nominally Potentiometer Operation Use 10K for full range Voltage Tolerance 48V Current Output 0 5mA with 1...

Страница 26: ...26 Dimensions...

Страница 27: ......

Страница 28: ...suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products with...

Отзывы: