background image

2

TD-001532-01-A

EXPLANATION OF TERMS AND SYMBOLS

The term “WARNING!” indicates instructions regarding personal safety. If the instructions are not followed the result may be bodily injury or death.

The term “CAUTION!” indicates instructions regarding possible damage to physical equipment. If these instructions are not followed, it may result in 
damage to the equipment that may not be covered under the warranty.

The term “IMPORTANT!” indicates instructions or information that are vital to the successful completion of the procedure.

The term "NOTE" is used to indicate additional useful information.

The intent of the lightning flash with arrowhead symbol in a triangle is to alert the user to the presence of un-insulated "dangerous" 
voltage within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans. 

The intent of the exclamation point within an equilateral triangle is to alert the user to the presence of important safety, and operating 
and maintenance instructions in this manual.

IMPORTANT SAFETY INSTRUCTIONS

 WARNRNG!:

 

TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN 

OR MOISTURE. 

• 

Elevated Operating Wmbient

 - If installed in a closed or multi-unit rack assembly, the ambient operating temperature of 

the rack environment may be greater than room ambient. Consideration should be given to ensure that the maximum operating 
temperature range (0°C to 50°C (32°F to 122°F ) is not exceeded. 

• 

Aeduced Wir Flow

 – Installation of the equipment in a rack should be such that the amount of air flow required for safe 

operation of the equipment is not compromised.

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Do not submerge the apparatus in water or liquids. 
7.  Do not use any aerosol spray, cleaner, disinfectant or fumigant on, near or into the apparatus. 
8.  Clean only with a dry cloth.
9.  Do not block any ventilation opening. Install in accordance with the manufacturer's instructions.
10.  Keep all ventilation openings free of dust or other matter.
11.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
12.  To reduce the risk of electrical shock, the power cord shall be connected to a mains socket outlet with a protective earthing connection.
13.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A 

grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided 
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

14.  Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from 

the apparatus.

15.  Do not unplug the unit by pulling on the cord, use the plug.
16.  Only use attachments/accessories specified by the manufacturer.
17.  Unplug this apparatus during lightning storms or when unused for long periods of time.
18.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as 

power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to 
rain or moisture, does not operate normally, or has been dropped.

19.  The appliance coupler, or the AC Mains plug, is the AC mains disconnect device and shall remain readily accessible after installation. 
20.  Adhere to all applicable, local codes.
21.  Consult a licensed, professional engineer when any doubt or questions arise regarding a physical equipment installation.

Содержание Q-SYS DCIO-H

Страница 1: ...Hardware User Guide Digital Cinema I O DCIO H Digital Cinema I O DCIO TD 001532 01 A TD 001532 01...

Страница 2: ...apparatus in water or liquids 7 Do not use any aerosol spray cleaner disinfectant or fumigant on near or into the apparatus 8 Clean only with a dry cloth 9 Do not block any ventilation opening Install...

Страница 3: ...ase the user will be required to correct the interference at his own expense IMPORTANT The Q SYS DCIO may operate at elevated temperatures and therefore its exterior may become noticeably warm This is...

Страница 4: ...da de QSC visite el sitio web de QSC LLC en www qsc com Pour obtenir une copie de la garantie limit e de QSC visitez le site de QSC LLC www qsc com Besuchen Sie die Webseite von QSC LLC www qsc com um...

Страница 5: ...ack Mounting CAUTION Be sure that each side has a minimum of 2 cm clearance The DCIO is designed to be mounted in a standard 19 480 mm equipment rack and requires 1 vertical rack space Secure the DCIO...

Страница 6: ...annels 9 16 Used for primary content audio from the server or media block Refer to Table 1 and Table 2 for pin out NOTE The AES3 connectors are NOT network connections 5 LAN connections RJ45 CAT 5E or...

Страница 7: ...32 wiring Figure 7 Table 1 AES3 INPUTS 1 8 Pin Description Channel 1 AES Pair 1 L R 2 AES Pair 1 3 AES Pair 2 C Sub 4 AES Pair 3 LS RS 5 AES Pair 3 6 AES Pair 2 C Sub 7 AES Pair 4 BL BR 8 AES Pair 4 T...

Страница 8: ...firmware currently installed on the DCIO Temp The current chassis temperature of the DCIO Level The current master level setting 100 dB to 20 dB Adjust with front panel rotary or in Q SYS Designer Mu...

Страница 9: ...ample rate detected at the HDMI Input Analog In Channel Status Mute Displays a muted loudspeaker when the channel is muted Signal Displays a blinking or solid circle when there is a signal present on...

Страница 10: ...10 TD 001532 01 A Dimensions Figure 16 18 9 in 481 mm 11 1 in 284 mm 11 3 in 288 mm 18 9 in 481 mm 1 7 in 44 mm...

Страница 11: ...Gigabit Ethernet Q LAN ports LAN A LAN B RJ45 x2 HDMI input output DCIO H only HDMI 2 0 Type A female connectors Power switch Rocker switch IEC Power Connector Audio Performance A D conversion 32 bit...

Страница 12: ...ge type Balanced output Max output level 18 dBu adjustable Dynamic range unweighted 110 dB THD N at 2dB below clip 009 Monitor Output Connector Euro style Output stage type Unbalanced output Max outpu...

Страница 13: ...675 MacArthur Boulevard Costa Mesa CA 92626 1468 U S Main Number 1 714 754 6175 World Wide Web www qsc com Sales Marketing Voice 1 714 957 7100 or toll free U S only 800 854 4079 FAX 1 714 754 6174 E...

Отзывы: