background image

 

1

 

IMPORTANT SAFETY PRECAUTIONS & EXPLANATION OF SYMBOLS    

 
 
 

 
 

 

 
 
 

 
 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 

 
 
 

The lighting flash with arrowhead symbol within an equilateral triangle is intended to alert the 
user to the presence of uninsulated “dangerous” voltage within the product’s enclosure that 
may be of sufficient magnitude to constitute a risk of electric shock to humans.   
 
 
The exclamation point within an equilateral triangle is intended to alert the user to the 
presence of important operating and maintenance (servicing) instructions in this manual.    
 
 
 
 
 

SAFEGUARDS 

Electrical energy can perform many useful functions. This unit has been engineered and 
manufactured to assure your personal safety. Improper use can result in potential electrical 
shock of fire hazards. In order not to defeat the safeguards, observe the following instructions 
for its installation, use and servicing.  
 
 
Caution: To reduce the risk of electric shock, do not remove the cover. No user-serviceable 
parts inside. Refer servicing to qualified service personnel.  
 
 
 
Warning: To prevent fire or electric shock, do not expose this equipment to rain or moisture. 
 
 
 
 
1 –  Maximum operating ambient temperature is 50°C (122°F).  
2 –  Never restrict airflow through the device vents. Please insure that the side panel vents are  
       unobstructed.  
3 –  When installing equipment into rack, distribute the units evenly. Otherwise, hazardous     
       conditions  
       could be created by an uneven weight distribution.  
4 –  Connect the unit only to a properly rated supply circuit. The DCP 300 is suitable for  
       connection to    
       100-240VAC, 50-60Hz with no special considerations other than the appropriate IEC power 
       cord.  
5 –  Reliable Earthing (grounding) of rack-mounted equipment should be maintained.  
 
 
 

LITHIUM BATTERY WARNING 

THE DCP 300 EQUIPMENT CONTAINS A NON-RECHARGEAB

L

E LITHIUM BATTERY. 

LITHIUM IS A CHEMICAL KNOWN TO THE STATE OF CALIFIRNIA TO CUASE CANCER OR 
BIRTH DEFECTS. THE NON-RECHARGEABLE LITHIUM BATTERY CONTAINED IN THIS 
EQUIPMENT MAY EXPLODE IF IT IS EXPOSED TO FIRE OR EXTREME HEAT. DO NOT SHORT 
CIRCUIT THE BATTERY. DO NOT ATTEMPT TO RECHARGE THE NON-RECHARGEABLE 
LITHIUM BATTERY.  

 
 

 

 

Содержание DCP 300 User m

Страница 1: ...TD 000285 00 rev 005 Digital Cinema Hardware User Manual DCP 300 Digital Cinema Processor...

Страница 2: ...inside Refer servicing to qualified service personnel Warning To prevent fire or electric shock do not expose this equipment to rain or moisture 1 Maximum operating ambient temperature is 50 C 122 F 2...

Страница 3: ...with a copy of proof of purchase i e sales receipt This warranty provides that the examination of the returned product must indicate in our judgment a manufacturing defect This warranty does not exte...

Страница 4: ...Manager Digital Cinema Amplifier DCA Digital Cinema Processor DCP BASIS RAVE and Intrinsic Correction are trademarks of QSC Audio Products LLC USA and Foreign Patents Pending Windows is a trademark of...

Страница 5: ...pport active 2 3 or 4 way systems QSControl net suite of applications including Venue Manager QSCreator Notify and API for 3rd Party control systems offer ultimate flexibility in management and allow...

Страница 6: ...multiplex from anywhere on the local network DCP 300 Front Panel Features 1 Power on switch 2 Monitor volume and parameter adjust this control has two modes of operation Speaker mode controls level to...

Страница 7: ...0 configuration and management via direct connection 16 10 100 Mbps Ethernet port for QSControl management and remote access 17 100 Mbps Ethernet ports CobraNet audio network Primary and Secondary bac...

Страница 8: ...and system management objects needed to configure the auditorium audio format selection of audio source material configure the DSP signal path apply crossovers and EQs define the routing of audio to t...

Страница 9: ...vels of password protection authentication rights QSCreator screens can be as elaborate as the system designer s imagination and can be created to depict the physical layout of the auditorium or the e...

Страница 10: ...rear rack support ears Ensure that these rear mounting points are securely fastened to rear rack rails or side walls Computer Requirements Software Installation Installing the DCP Manager and QSContro...

Страница 11: ...ay work with satisfactory results the QSC Dataport specification requires that all 15 conductors be present and that all audio I O conductors be shielded Therefore only QSC supplied Dataport cables sh...

Страница 12: ...e NC contact and the NO contact is not connected When the relay is energized the C terminal is connected to the NO contact and the NC contact is not connected QSControl Network Connect one end of a da...

Страница 13: ...5 6 7 8 9 10 11 12 13 Description not used not used Back Surr Lt not used not used Back Surr Rt GND Dig Inputs not used Right Extra Surr Left Surround Right not used not used Pin 14 15 16 17 18 19 20...

Страница 14: ...ms 5 pin Euro style x1 common GND Config and management interface 10 100 Mbps network management 100 Mbps primary backup network audio Configuration memory card 1 GB min Active balanced single ended u...

Страница 15: ...acts Max 30VDC output at 1A Can be wired as N O or N C Active color TFT 4 3 diagonal viewing area 16x9 Resistive 4 wire QSControl Network Protocol Data rate Connection requirements Audio Network Proto...

Страница 16: ...15 QSC Audio Products LLC 1675 MacArthur Boulevard Costa Mesa California 92626 USA PH 714 754 6175 FAX 714 754 6174 Copyright 2009 QSC Audio Products LLC All rights reserved...