Introduction - Networking the BASIS 902zz

The BASIS 902zz has two RJ-45 network connection ports on the rear panel. One port is labeled "QSControl" and supports standard 
10BASE-T Ethernet.  The other port is labeled "CobraNet" and supports 100BASE-TX, also known as "Fast Ethernet". In the following we 
describe the use of these ports and show example network connection schemes.

The BASIS 902zz supports two distinct kinds of network activity; the first is audio transport via CobraNet, and the second is control and 
monitoring via QSControl.net. The user can choose to install one network for CobraNet traffic and a second separate network for 
QSControl traffic. We call this the "Two Wire Interface". Alternately, it is possible to run both control and audio traffic over CobraNet 
via the CobraNet port. In this case the QSControl port is unused. We call this the "Single Wire Interface".

Under the most demanding real-time control conditions and when using the lowest latency CobraNet settings, users may experience 
better QSControl performance using separate networks, especially when displaying a great many real-time meters. For most applica-
tions, separate networks won't provide any discernible benefits and will of course cost more. We therefore recommend using the Sin-
gle Wire Interface when running CobraNet. 

Why CobraNet Needs Special Treatment:

Ordinary Ethernet traffic has no guaranteed time of delivery. Packets of information may arrive at their destination out of order and 
some may be delayed more than others. This is fine for E-mail and even for downloading MP3 files over the Internet. Everything ends up 
properly reassembled at the destination, but how long this takes will vary according to network loading, span, etc. In contrast, Cobra-
Net is "real time" - it delivers audio with a minimal, consistent transmission delay. CobraNet is designed to use as much of conventional 
networking technology as possible while providing both guaranteed time of delivery and isochronicity - maintaining a phase-locked 
sample-accurate clock across the entire network. These requirements mean that ordinary unregulated Ethernet data cannot be freely 
mixed with CobraNet information. The two can coexist on the same wire, but only by adhering to the proper rules.

To learn more about CobraNet and appropriate network topologies, please visit http://www.qscaudio.com/products/network/
resources.htm and http://www.peakaudio.com/CobraNet/background.html.

Notes on Network Systems Design:

As with any communications system, the reliability and performance of a local area network is intimately related to the designer's skill 
and knowledge in implementing a topology that is robust, efficient and standards-compliant. Proper network design is even more criti-
cal in distributed multimedia systems. Therefore, it is important for the system designer to realize that some conventional network 
practices must be avoided. Although each network design is unique and may carry its own performance requirements, compliance to 
the following three points will assist in building an audio network that is trouble free and efficient. 

First, audio and conventional data communications deliveries should not exist on the same LAN or VLAN. The exception to this is the 
BASIS 902zz Single Wire Interface, which offers a solution for converging audio and QSControl.net onto the same LAN or VLAN. How-
ever, conventional communications, such as corporate networks, print services, e-mail and Internet access, should not exist alongside 
CobraNet audio and QSControl.net on the same LAN or VLAN. Further, CobraNet audio and QSControl.net data should not exist 
together on the same LAN or VLAN when implementing the Two Wire Interface. This is not to say that conventional communications 
cannot share the same network hardware with a BASIS 902zz. In fact, common network hardware, such as managed Ethernet switches 
and media converters, can service both BASIS 902zz products and conventional data communications equipment so long as the man-
aged switch or media converter are partitioned into separate network domains. This is normally done by configuring a separate VLAN 
for each data type. (Some switches may allow individual port assignments or support partitions through DIP switch selection.)

Second, CobraNet audio must traverse either a repeater domain or a network switch domain. The point here is that the CobraNet port 
on a BASIS 902zz must connect directly to, and only to, either a repeater LAN or a switched Ethernet LAN. Hybrid networks containing 
both repeaters and switches are not permitted on the audio segment. Connecting the CobraNet port to a repeater that is in turn con-
nected to a network switch poses an illegal and non-compliant condition. We recommend always connecting the QSControl and/or 
CobraNet port(s) directly to network switch ports. 

Содержание BASIS 902zz

Страница 1: ...TD 000146 00 rev A BASIS 902zz 8 Output CobraNet Enabled Control and Monitoring Signal Processor Hardware Manual TD 000146 00 ...

Страница 2: ... cord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER OR BIRTH DEFECTS THE NON RECHARGE ABLE LITHIUM BATTERY CONTAINED IN THIS EQUIPMENT MAY EXPLODE IF IT IS EXPOSED TO FIRE OR EXTREME HEAT DO NOT SHORT CIRCUIT THE BA...

Страница 3: ...ling the overall BASIS QSControl system However the BASIS 902zz also offers a front panel interface for accessing critical functions A single QSControl server computer can support several cli ents running QSC s latest Venue Manager software Thus the sound system can be operated via several computers roaming wireless laptops tablets etc all at the same time from anywhere a connection to the QSContr...

Страница 4: ...net are available at www qscontrol net We invite you to visit us there We ve applied our many years experience in supporting high end installed sound with our previous system building products such as RAVE QSControl CM16a DSP 3 DSP 4 and DSP 30 The BASIS 902zz brings all that technology together in one compact powerful easy to use system We are confident that your new BASIS 902zz will provide year...

Страница 5: ...pologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background html Notes on Network Systems Design As with any communications system the reliability and performance of a local area network is intimately related to the designer s skill and knowledge in implementing a topology that is robust efficient and standards compliant Proper network ...

Страница 6: ...CP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl net segment does not require a single topology data path and therefore repeaters switches and routers may be assembled on the LAN in a hybrid fashion To learn more about network design rules and system compliance visit the QSC ne...

Страница 7: ...However you would have to physically connect your computer first to one BASIS box and then to the other With this elementary connection you don t have a true network It is like mak ing RS 232 connections except that performance is better All the other examples are of proper networks and all require a network switch On a proper network you have direct access to all units all of the time without hav...

Страница 8: ...his configuration works well when CobraNet audio deliveries are point to point Though the example shows only two units as many devices may be connected as there are available switch ports All BASIS RAVE units will be able to communicate simultaneously with the computer All will have access to CobraNet audio Switches can be con nected to other switches to build larger networks all of the normal net...

Страница 9: ...VLAN for QSControl net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for QSControl including the system controller and a second dedicated network for CobraNet audio As with the previous example as many BASIS RAVE units may be connected as there are switch ports avail able All units will be able to communicate with the computer A...

Страница 10: ...with its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network hardware The figure shows a separate net work switch for QSControl net traffic and a separate network switch for CobraNet audio traffic All of the previous comments regarding network expansion still ...

Страница 11: ...or out of an equipment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mounting Rack mount the BASIS 902zz by supporting it from underneath while aligning the mounting holes with the threaded screw holes in the rails install all four mounting screws and washers and tighte...

Страница 12: ... used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Panel features be disabled Display hard drive system standby and hibernation settings should be set to Never This avoids waiting for the system to wake up if adjustment is needed after an elapsed period of time To Install QSControl net 1 Start your computer and s...

Страница 13: ...ontroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the BASIS 902zz to synchronize with its internal clock If CobraNet network connection is re established the audio will mute again while the BASIS 902zz synchronizes with CobraNet Configuration Memories The BASIS 902zz ha...

Страница 14: ...vel and 0 5 VDC input The contact closure and logic devices accommodate on off or state change events the variable resistor input provides full 8 bit resolution allowing for incremental change events Refer to the illustrations for connection recommendations NOTE 48 volts is the absolute maximum that can be applied to the pin without damage Voltage is with respect to chassis or the pin Logic Out Th...

Страница 15: ...udio and amplifier status monitoring This can be four 2 channel amplifiers or one 8 channel amplifier or other suitable combinations If connecting a multi DataPort amplifier ensure all the DataPorts of the amplifier are con nected and that they are all connected to the same BASIS To connect the cable orient the connector properly then push into the receptacle until it is firmly seated tighten the ...

Страница 16: ...e display are used to navigate through the menus The rotary select accept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accepting choices entering by pushing in on the control The accessible menus and sub menus may appear differently than the example shown Software updates may occasionally improve the interface On the following page is a...

Страница 17: ...ult Boot Screen Right side buttons serve as up down navigation Arrow characters indi cate right side button context If additional menus are available the arrow character will be shown Main Menu Screens Note After successful pass word entry all screens with edit able parameters will have read write capability Without pass word entry these screens will be read only Utility Menu Screens Password Log ...

Страница 18: ... Client Server selection keep both Client and Server selected This will be appropriate for general use 8 When prompted Select Installation Folder specify the installation directory or accept the default location 9 You will be prompted to select an installation accessible by everyone non secure or an installation accessible only to you secure Select the appropriate Everyone or Just Me box and conti...

Страница 19: ...nnections verify IP addresses are set correctly ver ify Subnet masks are set correctly and verify AC power is properly applied to the BASIS 19 Click on the BASIS 902zz in the inventory root A view of applicable device tabs will open Click the DSP tab and the current DSP configuration of the BASIS will be displayed 20 Right click on the Design Editor icon in the lower left of your display select Ne...

Страница 20: ... used will be copies of other channels CobraNet Channel Resolution All CobraNet audio will be processed internally within BASIS 902zz at 24 bit resolution The BASIS 902zz may receive any valid resolu tion off of the network This is currently 16 bit 20 bit and 24 bit Audio via inbound bundles may be in any combination of these resolu tions and the BASIS will process the data accordingly All DACs wi...

Страница 21: ...municate with the BASIS 902zz if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port input output I O This I O port is used for accessing Ethernet IP settings stand alone control capabilities system health data firmware version information and other related data Should any system pr...

Страница 22: ...lick OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the letter h for help and then press the Enter key This will prompt the BASIS 902zz to post its menu text The h key is the Help prompt for the BASIS 902zz A text menu will appear This is sent by the BASIS 902zz ...

Страница 23: ... opening a Telnet session 1 To open the Telnet session Click Start select Run type Telnet followed by a space then the IP address of the BASIS 902zz you want to communicate with in the text box and click OK 2 If the address entered was correct and network communications with the BASIS 902zz are successful the Telnet session should open 3 Now you have the same options that are available in the Seri...

Страница 24: ...output 6 313 milliseconds 3 646 milliseconds Program Outputs 8 Connector Type 4 HD 15 dataport connections Cable Type QSC DataPort cable QSC p n DPC x x designates cable length in feet Available stock Lengths 1 2 3 4 5 6 10 and 20 ft custom lengths available Maximum Qualified Length 32 8 ft 10 m Control Room Foldback Monitoring Connector Type 5 pin Phoenix Style a k a Euro Style detachable termina...

Страница 25: ...uts 6 discrete inputs for TTL logic voltage control or passive resistive Connector Type 2 pin Phoenix Style a k a Euro Style detachable terminal blocks Configuration Single ended ground referenced Pinout 1 Signal 2 CHASSIS GND Normal Operating Range Reads signals between 0 5V nominally Potentiometer Operation Use 10K for full range Voltage Tolerance 48V Current Output 0 5mA with 10K pot for passiv...

Страница 26: ... suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products with your networking systems No agent employee or representative of QSC has any authority to alter or modify in any manner the disclosures and recommendations set forth herein QSC Audio Products 3 Year Li...

Отзывы: