QCX assembly Rev 1.08
51
The four windings on T1 must all be in the same “sense”. There are two ways to wind toroids. You
might call them left-handed and right-handed; clockwise and counter-clockwise; whether the wire
goes through the toroid from top to bottom, or from bottom to top. Whatever you call it, all the four
windings have to be the same, to be sure to get the phasing to the quadrature sampling detector
correct.
The number of turns in each winding depends on the band you are building the kit for. Refer to the
following table. For convenience, the remainder of the instructions in this section refer to the 20m
version (30 + 3 + 3 + 3 turns).
But MAKE SURE you wind the correct number of turns for your band!
Band
Primary
Secondary
1
Secondary
2
Secondary
3
80m
5
5
5
68
60m
5
5
5
46
40m
5
5
5
38
30m
4
4
4
30
20m
3
3
3
30
17m
3
3
3
22
Note for 80m and 60m versions:
the toroid ring is not large enough to neatly hold all of those
turns in a single flat tidy winding. The large secondary winding WILL end up looking messy, with
overlaps in some places. You should try to ensure any overlaps turns are evenly spaced
throughout the winding! Do not try to wind one neat layer, then wind the remaining turns as an
additional neat layer on top of that. Just go with the messy overlapping turns and don’t worry about
it: everything will work fine, regardless.
Содержание QCX 5W CW
Страница 9: ...QCX assembly Rev 1 08 9...
Страница 10: ...QCX assembly Rev 1 08 10...
Страница 12: ...QCX assembly Rev 1 08 12...
Страница 26: ...QCX assembly Rev 1 08 26 3 19 Install 20MHz crystal XTAL1 The engraving on this crystal is 20 000...
Страница 50: ...QCX assembly Rev 1 08 50...
Страница 105: ...QCX assembly Rev 1 08 105...