ACT88326
Advanced PMU with Bypass Switch,
& Pushbutton Function
Data Sheet Rev. 3.0, Nov. 11, 2019 | Subject to change without notice
10 of 45
www.qorvo.com
Startup Delay Programmable Range
ONDLY=00
ONDLY=01
ONDLY=10
ONDLY=11
0
0.25
0.5
1.0
ms
Turn Off Delay Programmable Range
Configurable in 0.25ms steps
0
7.75
ms
nRESET Programmable Range
Configurable to 20, 40, 60 or 100ms.
20
100
ms
Note 1: All Under-voltage Lockout, Overvoltage measurements are referenced to the AVIN Input and AGND Pins.
Note 2: All POK Under-voltage and Overvoltage measurements are referenced to the VIN Input and PGNDx Pins.
(ES) Equipements Scientifiques SA - Département Composants & Modules - 127 rue de Buzenval BP 26 - 92380 Garches
Tél. 01 47 95 99 84 - Fax. 01 47 01 16 22 - e-mail: [email protected] - Site Web: www.es-france.com