QNO QMS1024G Скачать руководство пользователя страница 104

 

Gigabit  Switch 

 

 

 

104 

 

The following table describes the labels in this screen. 

 

LABEL 

DESCRIPTION 

Target 

Select the target to store log message 

Buffered

: Store log messages in device buffer. All log messages will 

disappear after system reboot. 

FLASH

: Store log messages in FLASH. All log messages will not disappear 

after system reboot. 

Severity 

Select severity of log messages which will be stored.

 

Apply 

Click 

Apply 

to save your changes to the switch. 

Status 

It displays the status of local log settings. 

Target 

It 

displays the target you’ve chose. 

Severity 

It displays the severity status. 

Delete 

Click 

Delete

 to delete the target chose. 

 

 

3.8.4.3 Remote Logging 

 

This page allow user to configure remote logging server information 

Click 

Diagnostics 

→ 

Logging Setting 

→ 

Remote

 

Logging 

to view the screen as shown next. 

 

 

 

 

The following table describes the labels in this screen. 

 

LABEL 

DESCRIPTION 

Server IP 

The IP address of remote log server. 

Server Port 

Enter a number between 1 and 65535 as the server port. 

Severity 

Select severity of log messages which will be sent. 

Facility 

Select facility of log messages which will be sent. 

Содержание QMS1024G

Страница 1: ...Gigabit Switch 1 24 Port Gigabit Ethernet Web Managed Switch English User s Manual...

Страница 2: ...xpense This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interf...

Страница 3: ...T REBOOT 16 2 3 1 SAVE 16 2 3 1 1 Saving running configurations 16 2 3 2 LOGOUT 16 2 3 3 REBOOT 17 III Web Management Configuration 18 3 1 Status 18 3 1 1 System Information 18 3 1 2 Logging Message 1...

Страница 4: ...ss 74 3 6 QoS 76 3 6 1 General 76 3 6 2 QoS Basic Mode 83 3 6 3 Rate Limit 85 3 7 Management 87 3 7 1 LLDP 87 3 7 2 SNMP 97 3 8 Diagnostics 99 3 8 1 Cable Diagnostics 99 3 8 2 Ping Test 100 3 8 3 IPv6...

Страница 5: ...s that support auto discovery on LAN without memorizing IP address Smart Features The device provides rich features including Link Aggregation VLANs IGMP Snooping Port Trunking Spanning Tree Security...

Страница 6: ...ered on Off The switch is powered off SYS Steady Green The switch is on and functioning properly Blinking Green The switch is rebooting and performing self diagnostic tests Off The power is off or the...

Страница 7: ...ply in the range from 100 to 240 VAC 50 60 Hz Please make sure that your outlet standard to be within this range To power on the switch please plug the female end of the power cord firmly into the rec...

Страница 8: ...ith the female end of the provided power cord and plug the male end to the power outlet Rack mount Installation The switch may be standalone or mounted in a rack Rack mounting facilitate to an orderly...

Страница 9: ...ed To choose a suitable cable please refer to the following table Media Speed Wiring 10 100 1000 Mbps copper 10 Mbps Category 3 4 5 UTP STP 100 Mbps Category 5 UTP STP 1000 Mbps Category 5e 6 UTP STP...

Страница 10: ...raphic User Interface After the password authorization the information page shows up You may click on each folder on the left column of each page to get access to each configuration page The Graphic U...

Страница 11: ...click on a submenu link to open the screen in the main window B It shows the switch s current link status Green squares indicate the port link is up while black squares indicate the port link is down...

Страница 12: ...shown as the following Status Network Switching MAC Address Table Security QoS Management Diagnostics Maintenance The following table describes the links in the navigation panel LINKS DESCRIPTION Stat...

Страница 13: ...lnet Time Settings This link takes you to a screen where you can configure the switch s time settings Switching Port Setting This link takes you to a screen where you can configure settings for indivi...

Страница 14: ...ping DSCP Mapping and IP Precedence Mapping QoS Basic Mode This link takes you to a screen where you can configure the QoS Basic Mode through the sub menu including the Global Settings and the Port Se...

Страница 15: ...de Upgrade Manager This link takes you to a screen where you can upgrade the switch settings Configuration Manager This link takes you to a screen where you can save all the configurations you have ma...

Страница 16: ...n Configuration Manager Page Configuration Manager Fields LABEL DESCRIPTION Source File Select upgrade method Running configuration Running configuration file Startup configuration Startup configurati...

Страница 17: ...art the switch without physically turning the power off Follow the steps below to reboot the switch 1 Click REBOOT to view the screen as shown next 2 Click Reboot button then the following interface p...

Страница 18: ...below This page allow user to configure and browse some system information such as MAC address IP address loader version and firmware version and so on With Edit button in the table user could configu...

Страница 19: ...display the screen as shown below The following table describes the labels in this screen LABEL DESCRIPTION Target Select the log message source to show on the table Buffered Logs store in the device...

Страница 20: ...ormation 3 1 3 1 Port Counters Use this screen to display the Switch port statistics Click Status Port Port Counters to view the screen as shown next The following table describes the labels in this s...

Страница 21: ...efresh the web page every period of seconds IFG Inter Frame Gap in bandwidth calculation Enable Add inter frame gap to bandwidth calculation Disable Remove inter frame gap to bandwidth calculation 3 1...

Страница 22: ...groups of ports assigned to a static LAG are always active members LACP The groups of ports assigned to dynamic LAG are candidate ports LACP determines which candidate ports are active member ports Li...

Страница 23: ...the port no PRD means the port is in no periodic state FstPRD means fast periodic state SlwPRD means slow periodic state PrdTX means periodic TX state AtState The actor state field of LACP PDU descrip...

Страница 24: ...of insufficient resources Age Outs The number of times the complete set of information advertised by MSAP has been deleted from tables associated with the remote systems because the information timel...

Страница 25: ...le describes the labels in this screen LABEL DESCRIPTION Total RX This field displays the total amount of RX Valid RX This field displays the total amount of valid RX Invalid RX This field displays th...

Страница 26: ...Source query TX 3 2 Network Use the Network pages to configure settings for the switch network interface and how the switch connects to a remote server to get services 3 2 1 IP Address Use the IP Set...

Страница 27: ...enabled enter IP address in this field Subnet Mask Enter the IP subnet mask of your switch in dotted decimal notation for example 255 255 255 0 If static mode is enabled enter subnet mask in this fiel...

Страница 28: ...Disable this function IPv6 Address Enter the IPv6 address of your switch If auto configuration mode is disabled enter IPv6 address in this field Gateway Enter the IP address of the gateway in dotted d...

Страница 29: ...ys the static router of IPv6 DHCPv6 Client It displays the DHCPv6 Client Status 3 2 3 Management VLAN Click Network Management VLAN in the navigation panel to display the screen as shown below The fol...

Страница 30: ...the navigation panel to display the screen as shown below The following table describes the labels in this screen LABEL DESCRIPTION Enable SNTP Select the radio button to enable or disable using SNTP...

Страница 31: ...curring daylight saving time This field available when selecting Recurring mode Recurring To Specify the ending time of recurring daylight saving time This field available when selecting Recurring mod...

Страница 32: ...ing in the navigation panel to display the screen as shown below The following table describes the labels in this screen LABEL DESCRIPTION Port Select Select the port s from the list box that you will...

Страница 33: ...00 1000M ability only Flow Control A concentration of traffic on a port decreases port bandwidth and overflows buffer memory causing packet discards and frame losses Flow Control is used to regulate t...

Страница 34: ...state port base mirror or disable Destination Port Select mirror session destination port Allow ingress Select destination port ingress state Sniffer Rx ports Select mirror session source rx ports on...

Страница 35: ...e Algorithm Select the LAG load balance distribution algorithm MAC Address Based on source and destination MAC address for all packets IP MAC Address Based on source and destination IP addresses for I...

Страница 36: ...the trunk member ports in this field There are the following limitations for choosing the member ports All ports in a LAG must be of the same media type To add a port to the LAG it cannot belong to an...

Страница 37: ...oup of ports assigned to dynamic LAG are candidate ports LACP determines which candidate ports are active member ports Link State LAG port link status Active Member Active member ports of the LAG Stan...

Страница 38: ...0M 100M Auto speed with 10M 100M abilities 10M Force speed with 10M ability 100M Force speed with 100M ability 1000M Force speed with 1000M ability Flow Control Port flow control Enabled Enable flow c...

Страница 39: ...this screen LAG Setting Field LABEL DESCRIPTION System Priority Configure the system priority of LACP This decides the system priority field in LACP PDU Apply Click Apply to save your changes to the...

Страница 40: ...ply to save your changes to the Switch 3 3 4 VLAN Management A virtual local area network virtual LAN or VLAN is a group of hosts with a common set of requirements that communicate as if they were att...

Страница 41: ...Action Select the action of operation To add delete edit the VLANs VLAN Name Prefix Specify the prefix string of the VLAN name for new created VLANs This field is only available with add action Apply...

Страница 42: ...gged member of one VLAN at most and is a tagged member of zero or more VLANs PVID Specify the port based VLAN ID 1 4094 It s only available with Hybrid and Trunk mode Accepted Type Specify the accepta...

Страница 43: ...e specified VLAN ID Forbidden Specify the port is forbidden in the VLAN Excluded Specify the port is excluded in the VLAN Tagged Specify the port is tagged in the VLAN Untagged Specify the port is unt...

Страница 44: ...le describes the labels in this screen LABEL DESCRIPTION Port Display the interface of this port entry Mode Display the interface VLAN mode of this port Administrative VLANs Display the administrative...

Страница 45: ...VLANs to delete for this port Tagging Select the VLAN membership of the specified left VLANs for this port PVID Check this checkbox to select the VLAN ID to be the port based VLAN ID for this port 3 3...

Страница 46: ...sabled Voice VLAN ID Select Voice VLAN ID Cos 802 1p Select a value of vpt that will be advertised by LLDP MED 1p remark Select 1p remark state Aging Time Select value of aging time 3 3 4 6 Telephony...

Страница 47: ...ess Select oui address Description Description of the specified MAC address to the voice VLAN OUI table 3 3 4 7 Telephony OUI Port Setting This page allow user to configure Voice VLAN Properties setti...

Страница 48: ...pe value Cos Mode Select port cos mode Src QoS attributes are applied to packets with OUIs in the source MAC address All QoS attributes are applied to packets that are classified to the Voice VLAN 3 3...

Страница 49: ...one or multiple ports to configure State Port EEE function Enabled Enable EEE function Disabled Disable EEE function Apply Click Apply to save your changes to the switch 3 3 6 Multicast 3 3 6 1 Prope...

Страница 50: ...ast data to router port IPv4 Forward Method Set the ipv4 multicast forward method MAC forward method dmac vid Src Dst Ip forward method dip sip Apply Click Apply to save your changes to the switch 3 3...

Страница 51: ...MP Snooping Version Set the igmp snooping version v2 Only support process igmp v2 packet v3 Support v3 basic and v2 IGMP Snooping Report Suppression Set the enabling status of IGMP v2 report suppressi...

Страница 52: ...s tuning for the expected packet loss on a subnet Query Interval The interval of querier send general query Query Max Response Interval In Membership Query Messages it specifies the maximum allowed ti...

Страница 53: ...AN enable Disable IGMP VLAN disable Router Ports Auto Learn Set the enabling status of IGMP router port learning Enable Enable learning router port by query and PIM DVRMP Disable Disable learning dyna...

Страница 54: ...last member query interval Oper Last Member Query Interval The operation last member query interval Immediate leave Leave the group when receive IGMP Leave message Enable Enable Fastleave Disable Disa...

Страница 55: ...se VLANs Enable Enable IGMP Querier Disable Disable IGMP Querier Snooping State Set the query version of IGMP Querier Election on the chose VLANs v2 Querier version 2 v3 Querier version 3 Apply Click...

Страница 56: ...P address of this group Member Ports The member ports of this group Add Click Add to add IGMP Group to the switch Edit Click Edit to edit the IGMP Static Group Delete Click Delete to edit the IGMP Sta...

Страница 57: ...Group Table to access the screen below The following table describes the labels in this screen LABEL DESCRIPTION VLAN ID The VLAN ID of this group Group IP Address The group IP address of this group M...

Страница 58: ...xpiry Time Sec The expiry time of this group 3 3 7 Jumbo Frame This page allow user to configure switch port jumbo frame settings Click Switching Jumbo Frame in the navigation panel to bring up the sc...

Страница 59: ...to activate one of the STP modes on the switch Click Switching STP STP Global Setting The following table describes the labels in this screen LABEL DESCRIPTION Enabled Specify the STP status to be ena...

Страница 60: ...port s to change spanning tree protocol settings for Path Cost Path cost is the cost of transmitting a frame on to a LAN through that port It is recommended to assign this value according to the spee...

Страница 61: ...RST BPDUs and hence to test the hypothesis that all legacy systems that do not understand the new BPDU formats have been removed from the LAN segment on the port s Apply Click Apply to save your chang...

Страница 62: ...Max Age Set the time any switch should wait before trying to change the STP topology after unhearing Hello BPUD Tx Hold Count Set the Transmit Hold Count used to limit BPDU transmission rate Hello Ti...

Страница 63: ...ct the port list to specify which ports should apply this setting Priority Set the Port Priority to the selected ports in the CIST instance Apply Click Apply to save your changes to the switch 3 3 8 5...

Страница 64: ...uration BDPUs received TCN BDPUs Received It displays the TCN BDPUs received Configuration BDPUs Transmitted It displays the configuration BDPUs transmitted TCN BDPUs Transmitted It displays the Multi...

Страница 65: ...ation number the MAC address belongs to Type There are two types of MAC entry Unicast add a unicast MAC entry Multicast add a multicast MAC entry Port If Type is unicast select the port number of the...

Страница 66: ...ing Time 10 630 The Dynamic MAC address aging out value Apply Click Apply to save your changes to the switch 3 4 3 Dynamic Learned Click Status MAC Address Table Dynamic Learned in the navigation pane...

Страница 67: ...AC address the whole dynamic MAC table will be displayed or cleared View Click the View button to display the logs according the criteria specified in the fields above Clear Click this button to remov...

Страница 68: ...lculates by octet based Preamble IFG Select the rate calculates w o preamble IFG 20 bytes Excluded exclude preamble IFG 20 bytes when count ingress storm control rate Included include preamble IFG 20...

Страница 69: ...rt exceed storm control rate will be shutdown Storm Type Select the type of storm control Broadcast Broadcast packet Unknown Unicast Unknown unicast packet Unknown Multicast Unknown multicast packet R...

Страница 70: ...Configure port protect type Unprotected Unprotected port can communicate with all ports Protected Prevent protected ports from communicate with each other Apply Click Apply to save your changes to the...

Страница 71: ...Gigabit Switch 71 The following table describes the labels in this screen...

Страница 72: ...ed Enable the item DoS setting IPv4 Ping Max Size IPv4 PING packet with the length Disabled Disable the item DoS setting Enabled Enable the item DoS setting Ipv6 Ping Max Size IPv6 PING packet with th...

Страница 73: ...tem DoS setting TCP Fragment Offset 1 Fragmented TCP packets Disabled Disable the item DoS setting Enabled Enable the item DoS setting Apply Click Apply to save your changes to the Switch 3 5 3 2 DoS...

Страница 74: ...nother site as if the user s keyboard and display connected directly to the remote machine To display Telnet web page click Security Access Telnet The following table describes the labels in this scre...

Страница 75: ...able HTTP service Session Timeout Set session timeout minutes for user access WEB from HTTP protocol If user does not response after session timeout minute WEBUI will logout automatically 0 minutes me...

Страница 76: ...after session timeout minute WEBUI will logout automatically 0 minutes means never timeout Apply Click Apply to save your changes to the Switch 3 6 QoS Use the QoS pages to configure settings for the...

Страница 77: ...LABEL DESCRIPTION QoS Mode Select the QoS operation mode Disable Disable QoS Basic Set QoS to basic mode Apply Click Apply to save your changes to the switch 3 6 1 2 Port Settings Click QoS General P...

Страница 78: ...ault CoS 802 1p priority value for the selected ports Remark CoS Enable Disable CoS remark Remark DSCP Enable Disable DSCP remark Remark IP Precedence Enable Disable IP Precedence remark Apply Click A...

Страница 79: ...trict Priority Set queue to strict priority type WRR Set queue to Weight round robin type Weight If the queue type is WRR set the queue weight for the queue Apply Click Apply to save your changes to t...

Страница 80: ...s of service Class of service value Queue Select queue ID for the CoS value Apply Click Apply to save your changes to the switch Queue Queue ID Class of service Select CoS Value for the Queue ID 3 6 1...

Страница 81: ...is screen LABEL DESCRIPTION DSCP Select the DSCP value to mapping to the priority and drop precedence The DSCP range is 0 to 63 Queue Select queue ID for the DSCP value Apply Click Apply to save your...

Страница 82: ...gabit Switch 82 3 6 1 6 IP Precedence Mapping Click QoS General IP Precedence Mapping in the navigation panel to display the screen as shown below The following table describes the labels in this scre...

Страница 83: ...ion panel to display the screen as shown below The following table describes the labels in this screen LABEL DESCRIPTION Trust Mode Select the QoS operation mode CoS 802 1p Traffic is mapped to queues...

Страница 84: ...y Click Apply to save your changes to the switch 3 6 2 2 Port Settings Click QoS QoS Basic Mode Port settings in the navigation panel to display the screen as shown below The following table describes...

Страница 85: ...screen as shown below The following table describes the labels in this screen LABEL DESCRIPTION Port Select one or multiple ports to configure State Enable Disable ingress bandwidth control Rate Rate...

Страница 86: ...Select one or multiple ports to configure State Enable Disable ingress bandwidth control Rate Rate value 0 1000000 unit 16 Kbps Apply Click Apply to save your changes to the switch 3 6 3 3 Egress Queu...

Страница 87: ...Apply to save your changes to the switch 3 7 Management Use the Network pages to configure settings for the switch network interface and how the switch connects to a remote server to get services 3 7...

Страница 88: ...DU Disable Action Select LLDP PDU handling action to be filtered bridging or flooded when LLDP is globally disabled Transmission Interval Select the interval at which frames are transmitted The defaul...

Страница 89: ...Select the delay after an LLDP frame is sent range 1 8192 seconds default 3 Apply Click Apply to save your changes to the switch 3 7 1 2 LLDP Port Setting Click Management LLDP LLDP Port Setting to d...

Страница 90: ...X Transmit and receive LLDP PDUs both Apply Click Apply to save your changes to the switch Port Select Select specified port or all ports to configure optional TLVs Optional TLV Select Select the LLDP...

Страница 91: ...ly Click Apply to save your changes to the switch 3 7 1 3 LLDP Local Device Use the LLDP Local Device page to view LLDP local device information Click detail button on the page to view detail informat...

Страница 92: ...Gigabit Switch 92...

Страница 93: ...4 LLDP Remote Device Click Management LLDP LLDP Remote Device to display the screen as shown next Use the LLDP Remote Device page to view LLDP neighbors information Click Detail to view selected neig...

Страница 94: ...Gigabit Switch 94...

Страница 95: ...Gigabit Switch 95...

Страница 96: ...es This field displays the total in bytes Left to Send Bytes This field displays what is left to send in bytes Status This field displays whether the Switch is overloading or not Mandatory TLVs This f...

Страница 97: ...e following table describes the labels in this screen LABEL DESCRIPTION State SNMP daemon state Select Enabled to activate SNMP daemon Select Disabled to not use SNMP daemon Apply Click Apply to save...

Страница 98: ...allow the SNMP manager using this string to create or edit MIBs configure settings on the switch Add Click Add to add any other community No It displays the port number which in the community Communit...

Страница 99: ...dress where the traps from the switch are sent Community Name This field displays the password which is sent with each trap to the SNMP manager Version Indicates the SNMP trap supported version Possib...

Страница 100: ...r Test to view the screen as shown next The following table describes the labels in this screen LABEL DESCRIPTION Port The Selected Port ID Copper Test Click Copper to start the test 3 8 2 Ping Test C...

Страница 101: ...n is 4 Interval It displays time interval between each ping request packet Enter a number between 1 and 5 as the interval and the default configuration is 1 Size It displays the size of ping packet En...

Страница 102: ...e default configuration is 4 Interval It displays time interval between each ping request packet Enter a number between 1 and 5 as the interval and the default configuration is 1 Size It displays the...

Страница 103: ...s shown next The following table describes the labels in this screen LABEL DESCRIPTION Logging Service Enable disable logging system Apply Click Apply to save your changes to the switch 3 8 4 2 Local...

Страница 104: ...displays the status of local log settings Target It displays the target you ve chose Severity It displays the severity status Delete Click Delete to delete the target chose 3 8 4 3 Remote Logging This...

Страница 105: ...n status 3 8 5 Factory Default Follow the steps below to restore the switch back to the factory defaults 1 Click Diagnostics Factory Default to view the screen as shown next 2 Click the Restore button...

Страница 106: ...ops up 3 When it finished the switch has been restarted 3 9 Maintenance 3 9 1 Backup Manager This page allows user to backup the firmware image or configuration file on the switch to remote TFTP serve...

Страница 107: ...ver must be assigned Backup Type Select backup type Image Firmware image of current system Running Configuration Running Configuration file Startup Configuration Startup Configuration file Backup Clic...

Страница 108: ...P address of the TFTP server must be assigned File Name Firmware image or configuration file name on remote TFTP server If the TFTP upgrade method is selected the file name must be specified Browse Fi...

Страница 109: ...nager to view the screen as shown next Configuration Manager Page Configuration Manager Success Page LABEL DESCRIPTION Source File Select upgrade method Running configuration Running configuration fil...

Страница 110: ...e Select password type for new account Clear Text Password without encryption Encrypted Password with encryption No Password No password for new account Password If the password type is not No Passwor...

Страница 111: ...nsmission Mode 10 100Mbps Full duplex Half duplex 1000Mbps Full duplex Memory Flash 16MB DDR2 128MB MAC Address Table 8K Jumbo Frame 10K Bytes Buffer Memory 524 8K Bytes Temperature Operating 0 C 50 C...

Отзывы: