TCL-THOMSON Electronics R&D Center (Shen’Zhen Lab)
Chassis Name
NX56-LA
Serial No.
Issued on
2008-05-19
Page
Page 7 of 15
Updated on
2010-01-27
Version
2.2
3.2 RF AGC alignment
3.2.1 Method 1
A. Connect the detector as shown below (Picture 3.2) to collector of Q101.
B. Receive a grey scale signal with 70dBV amplitude.
C. Enter P-Mode, press “6” key on RC to select “AGCT”.
D. Adjust AGCT item until the output of the detector becomes 0.8Vpp
Picture 3.2
3.2.2 Method 2
A. Receive a grey scale signal with 60dBV amplitude.
B. Enter P-Mode, press “6” key on RC to select “AGCT”.
C. Adjust the “AGCT” value until the hint display “AGC” just change between “0” and “1”.
3.3 Screen & Focus adjustment
*Notes: Alignment below should be done after 15 minutes warm up of TV.
1. Input cross hatch pattern signal to RF input.
2. Enter P-Mode.
3. Press “0” key on the RC and the screen will become a horizontal line.
4. Adjust the “SCREEN” VR of the FBT until the horizontal line can just be seen barely
(minimum visible intensity).
PHWKRGZLWK$.%2))
1RWH
Adjust the “SCREEN” VR
PHWKRGZLWK$.%21
3XWWKH79LQ$9VRXUFHZLWKRXWLQSXWVLJQDO
(QWHU30RGHSUHVV5&NH\$7
$GMXVWWKH6&5((195RIWKH)%7XQWLO9*6WDWH/2:2.+,*+GLVSOD\2.
5. Press “0” key again on the RC to exit the screen voltage adjustment mode.
5. Adjust the “FCOUS” VR of the FBT until the vertical line and horizontal line becomes
clear, like picture 3.3.
Collector
of Q101
To CRO