background image

S i m p l i f y

59042-03 A

Page i

SANbox2-8c Fibre Channel Switch

Installation Guide

Содержание SANbox2-8c

Страница 1: ...S i m p l i f y D 59042 03 A Page i SANbox2 8c Fibre Channel Switch Installation Guide...

Страница 2: ...se without further testing or modification QLogic Corporation assumes no responsibility for any errors that may appear in this document QLogic SANbox SANbox2 SANblade SANsurfer and Multistage are trad...

Страница 3: ...6 BSMI Class A Statement 1 6 1 7 Laser Safety Information 1 7 1 8 Electrostatic Discharge Sensitivity ESDS Precautions 1 7 1 9 Accessible Parts 1 8 1 10 Pi ces Accessibles 1 8 1 11 Zug ngliche Teile 1...

Страница 4: ...5 Power Supply and Fan 2 10 2 6 Switch Management 2 10 Section 3 Planning 3 1 Devices 3 1 3 2 Multiple Chassis Fabrics 3 2 3 2 1 Domain ID Principal Priority and Domain ID Lock 3 2 3 2 2 Common Topol...

Страница 5: ...ris Installation 4 13 4 2 12 Configure the Switch 4 14 4 2 13 Configure the Ports 4 15 4 2 14 Cable Devices to the Switch 4 15 4 3 Install Firmware 4 16 4 3 1 Using SANbox Manager to Install Firmware...

Страница 6: ...14 Appendix A Specifications A 1 Fabric Specifications A 1 A 2 Maintainability A 2 A 3 Fabric Management A 3 A 4 Dimensions A 3 A 5 Electrical A 3 A 6 Environmental A 4 A 7 Regulatory Certifications A...

Страница 7: ...Set Log Command B 39 Set Port Command B 42 Set Setup Command B 43 Show Command B 48 Show Config Command B 60 Show Log Command B 63 Show Perf Command B 65 Show Setup Command B 67 Shutdown Command B 70...

Страница 8: ...LEDs 5 9 Tables Table Page 2 1 Serial Port Pin Identification 2 9 3 1 Port to Port Transmission Combinations 3 7 3 2 Port to Port Latency 3 7 4 1 Management Workstation Requirements 4 1 B 1 Command Li...

Страница 9: ...all user controls and connections Section 3 describes the factors to consider when planning a fabric Section 4 explains how to install and configure the switch Section 5 describes the diagnostic metho...

Страница 10: ...re Channel Arbitrated Loop FC AL 2 Rev 6 8 Fibre Channel Private Loop SCSI Direct Attach FC PLDA NCITS TR 19 1998 Fibre Channel 10 bit Interface Rev 2 3 Definitions of Managed Objects for the Fabric E...

Страница 11: ...shinweise Ein Warnhinweis weist auf das Vorhandensein einer Gefahr hin die m glicherweise Verletzungen zur Folge hat 4 3 4 5 Ein Vorsichtshinweis weist auf das Vorhandensein einer Gefahr hin die m gli...

Страница 12: ...erference in which case the user will be required to correct the interference at their own expense Neither the provider nor the manufacturer is responsible for any radio or television interference cau...

Страница 13: ...97 Safety of Information Technology Equipment Including Electrical Business Equipment EN60825 1 A11 1996 Safety of Laser Products Part 1 EN55022 1998 Limits and Methods of Measurement of Radio Interfe...

Страница 14: ...formation Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions 1 6 6 B...

Страница 15: ...ardous The International Electrotechnical Commission IEC 825 Laser Safety Standard requires labeling in English German Finnish and French stating that the product uses Class 1 lasers Because it is imp...

Страница 16: ...s 1 10 Pi ces Accessibles Les pi ces rempla ables Field Replaceable Units FRU du commutateur SANbox2 8c Fibre Channel Switch sont les suivantes Interfaces aux media d interconnexion appel s SFP transc...

Страница 17: ...free software to make sure the software is free for all its users This General Public License applies to most of the Free Software Foundation s software and to any other program whose authors commit...

Страница 18: ...elow refers to any such program or work and a work based on the Program means either the Program or any derivative work under copyright law that is to say a work containing the Program or a portion of...

Страница 19: ...le sections of that work are not derived from the Program and can be reasonably considered independent and separate works in themselves then this License and its terms do not apply to those sections w...

Страница 20: ...f distribution of executable or object code is made by offering access to copy from a designated place then offering equivalent access to copy the source code from the same place counts as distributio...

Страница 21: ...he free software distribution system which is implemented by public license practices Many people have made generous contributions to the wide range of software distributed through that system in reli...

Страница 22: ...PROGRAM IS WITH YOU SHOULD THE PROGRAM PROVE DEFECTIVE YOU ASSUME THE COST OF ALL NECESSARY SERVICING REPAIR OR CORRECTION 14 IN NO EVENT UNLESS REQUIRED BY APPLICABLE LAW OR AGREED TO IN WRITING WIL...

Страница 23: ...ion version 69 Copyright C year name of author Gnomovision comes with ABSOLUTELY NO WARRANTY for details type show w This is free software and you are welcome to redistribute it under certain conditio...

Страница 24: ...ing for the technical professional for both the SANblade HBAs and the SANbox2 switches From the training link at www qlogic com you may choose Electronic Based Training or schedule an intensive hands...

Страница 25: ...Serial port Power supply and fan Switch management Fabrics are managed with the SANbox Manager switch management application version 2 00 and the Command Line Interface CLI Refer to the SANbox2 8c 16...

Страница 26: ...set the switch or to place the switch in maintenance mode Maintenance mode sets the IP address to 10 0 0 1 and provides access to the switch for maintenance purposes when flash memory or the resident...

Страница 27: ...uminating all chassis LEDs 4 When the POST is complete the chassis LEDs extinguish leaving the Input Power LED and the Heartbeat LED illuminated The Heartbeat LED illuminates continuously while the sw...

Страница 28: ...tch from the fabric unplug the switch from the AC power source and contact your authorized maintenance provider 2 1 2 3 Heartbeat LED Amber The Heartbeat LED indicates the status of the internal switc...

Страница 29: ...d above their respective ports and provide port login and activity status information The ports self discover the proper mode when connected to public devices and other switches You can also configure...

Страница 30: ...liseconds This makes it possible to observe the transmission of a single frame When extending credits the Activity LED for a donor port will reflect the traffic of the recipient port Refer to Distance...

Страница 31: ...ent User s Guide for more information about defining port modes 2 2 3 1 Fabric Ports An FL_Port can support a loop of up to 126 public devices An FL_Port can also configure itself during the fabric lo...

Страница 32: ...agement workstation can be a Windows Solaris or a Linux workstation that is used to configure and manage the switch fabric You can manage the switch over an Ethernet connection using SANbox Manager th...

Страница 33: ...a null modem F F DB9 cable The pins on the switch RS 232 connector are shown in Figure 2 8 and identified in Table 2 1 Refer to Connect the Management Workstation to the Switch on page 4 7 for informa...

Страница 34: ...about the SANbox Manager application and its use In addition to SANbox Manager the switch supports the following management tools Telnet command line interface CLI File Transfer Protocol FTP Simple N...

Страница 35: ...y Use LC type cable connectors for SFP transceivers and SC type cable connectors for GBIC transceivers Consider the distribution of public and private devices as well as targets and initiators Public...

Страница 36: ...ent of the domain ID on that switch Switches come from the factory with the domain ID set to 1 the domain ID lock set to False and the principal priority set to 254 Refer to the SANbox2 8c 16 Switch M...

Страница 37: ...oop reduces latency because any switch can route traffic in the shortest direction to any switch in the loop The loop also provides failover should a switch fail The cascade fabric shown in Figure 3 1...

Страница 38: ...sh fabric shown in Figure 3 2 has the following characteristics Each link contributes up to 200 MB s of bandwidth between switches 400 MB s in full duplex Because of multiple parallel paths there is l...

Страница 39: ...witch by 200 MB s The Multistage fabric shown in Figure 3 3 has the following characteristics Each link contributes up to 200 MB s of bandwidth between chassis Competition for this bandwidth is less t...

Страница 40: ...types and SFP transceivers Each port is supported by a data buffer with a 12 credit capacity that is 12 maximum sized frames For fibre optic cables this enables full bandwidth over a distance of 20 ki...

Страница 41: ...s between the connecting switches The switch guarantees in order delivery with any number of links between chassis 3 3 3 Latency Latency is a measure of how fast a frame travels from one port to anoth...

Страница 42: ...bership in a zone can be defined by switch port number port Fibre Channel address or by device worldwide name WWN Devices can communicate only with devices that are members of the same zone A zone can...

Страница 43: ...all port modes 3 4 2 Access Control List Hard Zones Access Control List ACL zoning divides the fabric for purposes of controlling discovery and inbound traffic ACL zoning is a type of hard zoning that...

Страница 44: ...rsede both soft and ACL zone boundaries Membership can be defined only by domain ID and port ID VPF zoning supports all port modes 3 5 Fabric Management The SANbox Manager application and CLI execute...

Страница 45: ...Command on page B 43 for more information Switches come from the factory with fabric security disabled Consider your user accounts and determine whether user authentication is necessary Inter switch l...

Страница 46: ...3 Planning Security 3 12 59042 03 A D Notes...

Страница 47: ...tations running SANbox Manager are described in Table 4 1 Telnet workstations require an RJ 45 Ethernet port or an RS 232 serial port and an operating system with a Telnet client 4 1 2 Switch Power Re...

Страница 48: ...tions Operating temperature range 5 50 C 41 122 F Relative humidity 15 80 non condensing 4 2 Installing a Switch Unpack the switch and accessories The SANbox2 8c product is shipped with the components...

Страница 49: ...tributed evenly An unevenly loaded rack can become unstable possibly resulting in equipment damage or personal injury CAUTION If the switch is mounted in a closed or multi unit rack assembly make sure...

Страница 50: ...his product is supplied with a 3 wire power cable and plug for the user s safety Use this power cable in conjunction with a properly grounded outlet to avoid electrical shock An electrical outlet that...

Страница 51: ...nal de 10 A conforme au H05VV F et agr VDE SEMKO et DEMKO WARNUNG Dieses Produkt wird mit einem 3 adrigen Netzkabel mit Stecker geliefert Dieses Kabel erf llt die Sicherheitsanforderungen und sollte a...

Страница 52: ...executes and all LEDs illuminate 4 When the POST is complete all LEDs are extinguished except the Input Power LED and the Heartbeat LED The Input Power LED remains illuminated indicating that the swit...

Страница 53: ...agement workstation to the switch RJ 45 Ethernet connector This requires a 10 100 Base T cross over cable as shown in Figure 4 2 With this method you can manage the switch with the SANbox Manager appl...

Страница 54: ...bric security The default account name and password are admin password SANbox2 Login admin Password 4 2 4 2 Serial Connection To establish a serial port connection do the following 1 Connect a null mo...

Страница 55: ...ox2 3 Log in to the switch If fabric security is disabled account names and passwords are not enforced Refer to the Set Setup Command on page B 43 for information about setting fabric security The def...

Страница 56: ...htm file to open the SANsurfer Management Suite start page in your default browser 2 On the SANsurfer Management Suite start page choose the SANbox Switch Software button 3 On the SANbox Switch Softwa...

Страница 57: ...ng command mount mnt cdrom c Execute your web browser to view the Start_Here htm document using one of the following commands mozilla file mnt cdrom Start_Here htm or netscape file mnt cdrom Start_Her...

Страница 58: ...er double click the Start_Here htm file to open the SANsurfer Management Suite start page in your default browser 2 On the SANsurfer Management Suite start page choose the SANbox Switch Software butto...

Страница 59: ...programs currently running and insert the SANbox2 Installation Disk into the management workstation CD ROM drive 2 Open the File Manager and double click on the CD ROM icon 3 Double click the SANbox_M...

Страница 60: ...efault fabric security is disabled and therefore account names and passwords are not enforced Refer to the Set Setup Command on page B 43 for information about setting fabric security 4 Open the Switc...

Страница 61: ...E_Ports when connected to another switch Refer to the SANbox2 8c 16 Switch Management User s Guide for more information about configuring ports You can also configure ports using the CLI Refer to Appe...

Страница 62: ...age file using the CLI Image command Refer to Using the CLI to Install Firmware on page 4 17 When using the CLI on a workstation without an FTP server you must open an FTP session through the switch t...

Страница 63: ...to retrieve the firmware file from the specified IP address SANbox2 admin image fetch username 10 0 0 254 firmwarefilenametoload firmwarefilenameonswitch Connected to 10 0 0 254 331 Password required...

Страница 64: ...dress and switchname is the switch name associated with the IP address 4 Enter the following account name and password user images password images 5 Activate binary mode and copy the firmware image fi...

Страница 65: ...ame 12 If the new firmware is later than version 2 0 the new firmware can be activated without disrupting traffic Enter the Hotreset command to perform a non disruptive activation SANbox2 admin hotres...

Страница 66: ...4 Installation Powering Down a Switch 4 20 59042 03 A D Notes...

Страница 67: ...loopback test on all ports Access and integrity test on the ASIC During the POST the switch logs any errors encountered Some POST errors are fatal others are non fatal The switch uses the Heartbeat LE...

Страница 68: ...n to reset the switch 5 1 1 4 Fatal Error Blink Pattern A fatal error blink pattern is 3 blinks per second followed by a two second pause The 3 blink error pattern indicates that a fatal error has lef...

Страница 69: ...ng 10 0 0 1 Connected to 10 0 0 1 Escape character is 5 The following menu is displayed Enter 6 Remake Filesystem and press the Enter key to recreate the configuration file 0 Exit 1 Image Unpack 2 Res...

Страница 70: ...switch using Telnet Enter one of the following on the command line telnet xxx xxx xxx xxx or telnet switchname where xxx xxx xxx xxx is the switch IP address and switchname is the switch name associat...

Страница 71: ...er second as shown in Figure 5 2 Error Flashes at roughly twice per second as shown in Figure 5 2 Figure 5 2 Logged In LED Indications If a Logged In LED shows an error indication review the alarm log...

Страница 72: ...r Switch Properties window Reset the port If the condition remains continue 2 Compare the RA_TOV and ED_TOV timeout values for all switches in the fabric using the Show Config Switch command or the Sw...

Страница 73: ...ng its operational state to down Port errors can be caused by the following Thresholds are too low or the sample interval is too small Faulty Fibre Channel port cable Faulty SFP Faulty port Fault devi...

Страница 74: ...e port pass the test Yes Continue No Replace the SFP and repeat the test If the port does not pass the test contact your authorized maintenance provider Otherwise continue 3 Replace the Fibre Channel...

Страница 75: ...nates to indicate that the switch logic circuitry is overheating If the Over Temperature LED illuminates do the following 1 Inspect the chassis fan Is the intake opening clear Is the fan operating and...

Страница 76: ...damaged Yes Make necessary corrections or repairs If the condition remains continue No Continue 2 Inspect the AC power source Is the power source delivering the proper voltage Yes Continue No Make ne...

Страница 77: ...all switch configuration parameters to the factory default values Reset the switch Display firmware versions stored on the switch Select the firmware image to activate To recover a switch do the foll...

Страница 78: ...press and release the Maintenance button or power cycle the switch 5 3 2 Maintenance Image Unpack This option unpacks and installs new firmware when the current firmware has become corrupt Before usin...

Страница 79: ...tion parameters to the factory defaults except for user accounts and zoning Refer to Table B 3 though Table B 8 for the factory default values 5 3 7 Maintenance Remake Filesystem In the event of sudde...

Страница 80: ...image numbers and firmware versions that are stored on the switch 5 3 10 Maintenance Set Active Image This option specifies the firmware version to be used when the switch returns to normal operation...

Страница 81: ...PH 3 FC AL Rev 4 5 FC AL 2 Rev 7 0 FC FLA FC GS 3 FC FG FC PLDA FC Tape FC VI FC SW 2 Fibre Channel Element MIB RFC 2837 Fibre Alliance MIB Version 4 0 Fibre Channel Classes of Service Classes 2 and...

Страница 82: ...c Port Speed 1 0625 or 2 125 Gigabits second Maximum Frame Size 2148 bytes 2112 byte payload System Processor 266 MHz Geode processor Fabric Latency best case 0 4 sec Fabric Point to Point Bandwidth 2...

Страница 83: ...nnector 10 100 BASE T cable Switch Agent Allows a network management station to obtain configuration values traffic information and failure data pertaining to the Fibre Channels using SNMP through the...

Страница 84: ...n operating IEC 68 2 5 500 Hz random 0 21 G rms 10 minutes 5 500 Hz random 2 09 G rms 10 minutes Shock Operating Non operating IEC 68 2 4 g 11ms 20 repetitions 30g 292 ips 3 repetitions 3 axis Air flo...

Страница 85: ...Cable Fibre Channel 100 M6 SN I 50 m multimode Fibre Channel 200 M5 SN I or 200 M6 SN I 62 5 m multimode Wavelength 830 860 nm Transmit Power 10 dBm minimum Receiver Sensitivity 16 dBm average Distanc...

Страница 86: ...Color coding Blue exposed connector surfaces Cable Fibre Channel 100SM LC L 9 m single mode Wavelength 1270 13 5 nm Transmit Power 10 dBm minimum Receiver Sensitivity 20 dBm average Distance 2 meters...

Страница 87: ...m the factory with the following user account already defined Account name admin Password password Authority Admin This user account provides full access to the switch and its configuration After plan...

Страница 88: ...ed form that can be used For example the Delete keyword can be abbreviated Del A command line completion feature makes entering and repeating commands easier Table B 1 describes the command line compl...

Страница 89: ...ommand on page B 4 The commands and their page numbers are listed by authority level in Table B 2 Table B 2 Commands Listed by Authority Level User Authority Commands Admin Authority Command Help Hist...

Страница 90: ...ds start or begin Opens the admin session end or stop Closes the admin session The Hardreset Hotreset Logout Shutdown and Reset Switch commands will also end an admin session cancel Terminates an Admi...

Страница 91: ...ce Fibre Channel address hex 16 character hexadecimal worldwide port name WWPN with the format xx xx xx xx xx xx xx xx The application verifies that the alias format is correct but does not validate t...

Страница 92: ...n by members from the alias given by alias members can have one of the following formats Domain ID and port number pair Domain ID Port Number Domain IDs and port numbers are in decimal Ports are numbe...

Страница 93: ...data which contains the system configuration information To download this file open an FTP session log in with account name password of images for both and type get configdata Refer to Examples cancel...

Страница 94: ...10 configurations including the default configuration Notes If you edit the active configuration changes will be held in suspense until you reactivate the configuration or activate another configurat...

Страница 95: ...from the workstation to the switch and then restore the configuration ftp symbolic_name or ip_address user images password images ftp bin ftp put configdata ftp quit SANbox2 admin start SANbox2 admin...

Страница 96: ...MMDDhhmmCCYY The new date and time takes effect immediately Authority Admin to change the date User to display the date Syntax date MMDDhhmmCCYY Keywords MMDDhhmmCCYY Specifies the date this requires...

Страница 97: ...mand displays the two firmware images active firmware inactive firmware and pending firmware versions After executing the Fallback command reset the switch to activate the pending firmware Use the Hot...

Страница 98: ...rms a power on self test This reset activates the pending firmware and disrupts traffic Authority Admin Syntax hardreset Notes To reset the switch without a power on self test refer to the Reset Comma...

Страница 99: ...fied command all Displays a list of all available commands including command variations Examples The following is an example of the Help Set command SANbox2 help set set SET_OPTIONS There are many att...

Страница 100: ...History display Enter partial command string to re execute a command that matches the command string Enter to re execute the most recent command Examples The following is an example of the History co...

Страница 101: ...econds Authority Admin Syntax hotreset Notes Non disruptive firmware activation is possible under the following conditions The active firmware must be version 2 0 or greater and the new firmware to be...

Страница 102: ...file_destination The image file is retrieved from the device with the IP address given by ip_address and an account name given by account_name If an account name needs a password to access the device...

Страница 103: ...03 A B 17 D Lip Command Reinitializes the specified loop port Authority Admin Syntax lip port_number Keywords port_number The number of the port to be reinitialized Examples The following is an examp...

Страница 104: ...t name You must open an admin session to change the password for an account name other than your own If you omit account_name you will be prompted to change the password for the current account name E...

Страница 105: ...ip_address The IP address of the switch to query Examples The following is an example of a successful Ping command SANbox2 ping 10 20 11 57 Ping command issued Waiting for response SANbox2 Response s...

Страница 106: ...18 35 ds 342 327 0 2 00 11 29 3 01 18 35 mgmtApp 343 327 0 0 00 00 04 3 01 18 35 fc2 344 327 0 0 00 02 16 3 01 18 35 nserver 345 327 0 0 00 02 44 3 01 18 35 mserver 346 327 0 8 00 35 12 3 01 18 35 ut...

Страница 107: ...B Command Line Interface Quit Command 59042 03 A B 21 D Quit Command Closes the Telnet session Authority User Syntax quit exit or logout Notes You can also enter Control D to close the Telnet session...

Страница 108: ...tion SNMP configuration system configuration and zoning to the factory default values The switch configuration is activated automatically Refer to Table B 3 through Table B 8 port port_number Reinitia...

Страница 109: ...Hex Domain ID Lock False Symbolic Name SANbox2 R_A_TOV 10000 E_D_TOV 2000 Principal Priority 254 Configuration Description QLogic SANbox2 FC Switch Configuration Last Saved By Initial Configuration La...

Страница 110: ...lts Parameter Default ThresholdMonitoringEnabled False CRCErrorsMonitoringEnabled RisingTrigger FallingTrigger SampleWindow True 25 1 10 DecodeErrorsMonitoringEnabled RisingTrigger FallingTrigger Samp...

Страница 111: ...2 AutoSave True Default All Table B 7 SNMP Configuration Defaults Parameter Default Contact syscontact undefined Location sysLocation undefined Description QLogic SANbox2 FC Switch Trap 1 5 Address T...

Страница 112: ...0 0 0 Ethernet Gateway Address 10 0 0 254 Fibre Channel Network Discovery Static Fibre Channel Network IP Address 0 0 0 0 Fibre Channel Network IP Mask 255 0 0 0 Fibre Channel Gateway Address 10 0 0...

Страница 113: ...owing on Enables the flashing beacon off Disables the flashing beacon config option Sets switch port alarm threshold and zoning configuration parameters Refer to the Set Config Command on page B 29 lo...

Страница 114: ...age B 43 switch state Temporarily changes the administrative state for all ports on the switch to the state given by state The previous Set Config Switch settings are restored after a switch reset or...

Страница 115: ...escribes the port parameters ports port_number Initiates an editing session in which to change configuration parameters for all ports based on the configuration for the port given by port_number If yo...

Страница 116: ...This parameter is ignored if IOStreamGuard is enabled ARB_FF Send ARB_FF True instead of IDLEs False on the loop The default is False InteropCredit Interoperability credit The number of buffer to buff...

Страница 117: ...lity to remain in the open state indefinitely True reduces the amount of arbitration on a loop when there is only one device on the loop The default is False IOStreamGuard I O Stream Guard Enable Enab...

Страница 118: ...and management Enables True or disables False the ability to manage the switch over an ISL The default is True DefaultDomainID Default domain ID The default is 1 DomainIDLock Prevents True or allows F...

Страница 119: ...Threshold parameters The switch will down a port if an alarm condition is not cleared within three consecutive sampling intervals by default 30 seconds Reset the port to bring it back online An alarm...

Страница 120: ...eration of alarms for each of the following events CRC errors Decode errors ISL connection count Device login errors Device logout errors Loss of signal errors Rising Trigger The event count above whi...

Страница 121: ...ent value shown in brackets Table B 12 Set Config Zoning Parameters Parameter Description FC SW 2 AutoSave Available only when the FC SW 2 Compliant parameter is True this parameter enables True or di...

Страница 122: ...1Gb s 2 2Gb s 3 Auto Auto PortType TL GL G F FL Donor GL ISLSecurity Any Ours None Any SymPortName string max 32 chars Port2 ALFairness True False False DeviceScanEnable True False True ForceOfflineRS...

Страница 123: ...ue 100 100000 msec 10000 E_D_TOV decimal value 10 20000 msec 2000 PrincipalPriority decimal value 1 255 254 ConfigDescription string max 32 chars FC SW 2 Compliant True False True The following is an...

Страница 124: ...1 1000 sec 10 Finished configuring attributes This configuration must be saved see config save command and activated see config activate command before it can take effect To discard this configuratio...

Страница 125: ...default stop Keywords archive Concatenates the individual event log files logfile logfile 1 logfile 2 logfile 3 logfile 3 logfile 4 logfile 5 and stores the result in new file named logfile that is ma...

Страница 126: ...itch performance do not use this setting with the Component keyword set to All None Monitors none of the severity levels port port_list Specifies one or more ports to monitor for events Choose one of...

Страница 127: ...n the Port Component and Level keywords assigned to the current configuration The logging continues until you enter the Set Log Stop command stop Stops logging of events Notes To maintain optimal swit...

Страница 128: ...ysical Address ALPA or to all ALPAs on the arbitrated loop alpa can be a specific ALPA or the keyword ALL to choose all ALPAs clear Clears the counters on the specified port enable Sends a Loop Port E...

Страница 129: ...are sent The default address for trap 1 is 10 0 0 254 The default address for traps 2 5 is 0 0 0 0 Addresses other than 0 0 0 0 for all traps must be unique Trap 1 5 Port Specifies the workstation por...

Страница 130: ...se SNMP communication with other switches in the fabric The default is True Note Changing the IP address will terminate all Ethernet management sessions Table B 14 System Configuration Settings Entry...

Страница 131: ...hich a warning condition alarm is generated The default is 65 C TempMonitoringFailure Failure temperature threshold in C above which a failure condition alarm is generated The default is 70 C TempFail...

Страница 132: ...alse Trap3Address dot notated IP Address 0 0 0 0 Trap3Port decimal value 162 Trap3Severity see allowed options above warning Trap3Version 1 2 2 Trap3Enabled True False False Trap4Address dot notated I...

Страница 133: ...s dot notated IP Address 10 0 0 1 Eth0NetworkMask dot notated IP Address 255 255 255 0 Eth0GatewayAddress dot notated IP Address 10 0 0 254 FCNetworkDiscovery 1 Static 3 Dhcp Static FCNetworkAddress d...

Страница 134: ...n_id support switch topology users version Keywords about Displays an introductory set of information about operational attributes of the switch This keyword is equivalent to the Version keyword alarm...

Страница 135: ...lues are in 1K block units ns option Displays name server information for the specified option If you omit option name server information for the local domain ID is displayed option can have the follo...

Страница 136: ...ames sent by this port ClassXWordsIn Number of class x words received by this port ClassXWordsOut Number of class x words sent by this port ClassXToss Number of times an SOFi3 or SOFn3 frame is tossed...

Страница 137: ...s performed after a link failure Login Number of device logins Logout Number of device logouts LoopTimeouts A two 2 second timeout as specified by FC AL 2 LossOfSync Number of synchronization losses 1...

Страница 138: ...at the request of your authorized maintenance provider The commands that are executed include the following Alias List Config List Date History Ps Show About Alarm Backtrace Chassis Config Port Confi...

Страница 139: ...SANbox2 show chassis Chassis Information BoardTemp 1 Degrees Celsius 34 BoardTemp 2 Degrees Celsius 31 FanStatus 1 Good PowerSupplyStatus 1 Good HeartBeatCode 1 HeartBeatStatus Normal The following is...

Страница 140: ...20 37 73 13 69 20 00 00 20 37 73 13 69 2 19 0x13 1301e2 NL 3 21 00 00 20 37 73 12 9b 20 00 00 20 37 73 12 9b 3 19 0x13 1301e4 NL 3 21 00 00 20 37 73 05 26 20 00 00 20 37 73 05 26 4 19 0x13 130d00 N 3...

Страница 141: ...packets 4712 errors 0 dropped 0 overruns 0 frame 0 TX packets 3000 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 100 RX bytes 415313 405 5 Kb TX bytes 716751 699 9 Kb Interrupt 11 Ba...

Страница 142: ...t MaxCredit 12 XmitterEnabled True OperationalState Offline ALInit 0 LIP_F8_AL_PS 0 ALInitError 0 LIP_F8_F7 0 BadFrames 0 LinkFailures 26 Class2FramesIn 0 Login 25 Class2FramesOut 0 Logout 24 Class2Wo...

Страница 143: ...ate time year ActiveImageVersion build date V2 0 0 0 2 day month date time year PendingImageVersion build date V2 0 0 0 17 day month date time year ActiveConfiguration default AdminState Online AdminM...

Страница 144: ...rtID 650100 PortWWN 20 01 00 c0 dd 00 91 11 PortType F Remote Link Information Device 0 NodeWWN 50 80 02 00 00 06 d5 38 PortType NL Description NULL IPAddress 0 0 0 0 Device 1 NodeWWN 20 00 00 20 37 2...

Страница 145: ...SystemDescription QLogic SANbox2 FC Switch Eth0NetworkAddress 10 20 11 192 use set setup system to update FCNetworkAddress 0 0 0 0 use set setup system to update MACAddress 00 c0 dd 00 71 ee WorldWid...

Страница 146: ...ecified switch Displays configuration parameters for the switch threshold Displays alarm threshold parameters for the switch zoning Displays zoning configuration parameters for the switch Examples The...

Страница 147: ...tSavedBy admin OB session5 ConfigLastSavedOn day month date time year FC SW 2 Compliant True Legacy Address Format False1 The following is an example of the Show Config Threshold command SANbox2 show...

Страница 148: ...LogoutMonitoringEnabled True RisingTrigger 5 FallingTrigger 1 SampleWindow 10 LOSMonitoringEnabled True RisingTrigger 100 FallingTrigger 5 SampleWindow 10 The following is an example of the Show Conf...

Страница 149: ...r on a component which is not defined no entry is made in the log options Displays the options used to set the component and log level attributes port Displays the ports being monitored for events If...

Страница 150: ...time year I Eport Port 0 8 FSPF PortUp state 0 329 day month date time year I Eport Port 0 8 Sending init hello 330 day month date time year I Eport Port 0 8 Processing EFP oxid 0x8 331 day month dat...

Страница 151: ...display outbyte Displays continuous performance data in bytes second transmitted for all ports Type q and press the Enter key to stop the display frame port_number Displays continuous performance data...

Страница 152: ...4 0 0 0 0 0 0 5 0 0 0 0 0 0 6 0 7K 7K 0 245 245 7 136M 58K 136M 68K 1K 70K The following is an example of the Show Perf Byte command SANbox2 show perf byte Displaying bytes sec data Press q and the EN...

Страница 153: ...ystem Displays the current system settings Examples The following is an example of the Show Setup Mfg command SANbox2 show setup mfg Manufacturing Information BrandName QLogic BuildDate Unknown Chassi...

Страница 154: ...Trap1Severity warning Trap1Version 2 Trap1Enabled False Trap2Address 0 0 0 0 Trap2Port 162 Trap2Severity warning Trap2Version 2 Trap2Enabled False Trap3Address 0 0 0 0 Trap3Port 162 Trap3Severity war...

Страница 155: ...tic Eth0NetworkAddress 10 20 11 32 Eth0NetworkMask 255 255 252 0 Eth0GatewayAddress 10 20 8 254 FCNetworkDiscovery Static FCNetworkAddress 0 0 0 0 FCNetworkMask 255 0 0 0 FCGatewayAddress 10 0 0 254 A...

Страница 156: ...switch at convenient points and closes the Telnet session Always power cycle the switch after entering this command Authority Admin Syntax shutdown Notes Always use this command to perform an orderly...

Страница 157: ...ave the following values internal Tests the SerDes This is the default The port must be in diagnostics mode to perform this test external Tests both the SerDes and SFP The port must be in diagnostics...

Страница 158: ...parameter is the pattern in the payload 6 After the test type has been chosen and the command executed a message on the screen will appear detailing the test results 7 After the test is run put the po...

Страница 159: ...unning the test make sure that the device attached to the port can handle the test parameters SANbox2 admin test port x online A list of attributes with formatting and current values will follow Enter...

Страница 160: ...last reset and reset method A hot reset or non disruptive firmware activation does not reset the elapsed up time reported by this command Authority User Syntax uptime Examples The following is an exa...

Страница 161: ...hout Admin authority you are limited to view only commands The expiration date is expressed in the number of days until the account expires 2000 maximum The switch will issue an expiration alarm every...

Страница 162: ...with admin authority and to expire in 100 days Please confirm y n n y The following is an example of the User Delete command SANbox2 admin user del user3 The user account will be deleted Please confir...

Страница 163: ...Command Displays the account name session number and switch domain ID for the Telnet session Authority User Syntax whoami Examples The following is an example of the Whoami command SANbox2 whoami User...

Страница 164: ...n have one of the following formats Domain ID and port number pair Domain ID Port Number Domain IDs and port numbers are in decimal Ports are numbered beginning with 0 6 character hexadecimal device F...

Страница 165: ...ing with 0 6 character hexadecimal device Fibre Channel address hex 16 character hexadecimal worldwide port name WWPN with the format xx xx xx xx xx xx xx xx Alias name rename zone_old zone_new Rename...

Страница 166: ...23bd31 zone_set_1 wwn_221416 zone_set_1 wwn_2215c3 zone_set_1 wwn_0160ed zone_set_1 wwn_c001b0 zone_set_1 wwn_401248 zone_set_1 wwn_02402f zone_set_1 wwn_22412f zone_set_1 The following is an example...

Страница 167: ...B Command Line Interface Zone Command 59042 03 A B 81 D The following is an example of the Zone Zonesets command SANbox2 zone zonesets zone1 Current List of ZoneSets for Zone wwn_b0241f zone_set_1...

Страница 168: ...oning Edit session before using this keyword active Displays the name of the active zone set This keyword is available with User authority and does not require a Zoning Edit session add zone_set zone_...

Страница 169: ...res a Zoning Edit session rename zone_set_old zone_set_new Renames the zone set given by zone_set_old to the name given by zone_set_new You can rename the active zone set This keyword requires a Zonin...

Страница 170: ...B Command Line Interface Zoneset Command B 84 59042 03 A D The following is an example of the Zoneset Zones command SANbox2 zoneset zones ssss Current List of Zones for ZoneSet ssss zone1 zone2 zone3...

Страница 171: ...changes are lost clear Clears all inactive zone sets from the volatile edit copy of the zoning database This keyword does not affect the non volatile zoning database However if you enter the Zoning Cl...

Страница 172: ...Zoning Edit session The system will inform you that the zone set must be activated to implement any changes This does not apply if you entered the Zoning Clear command during the Zoning Edit session E...

Страница 173: ...oneDomainPort 4 ZoneFCAddr MaxMembersPerAlias 2000 2 AliasInAZone The following is an example of the Zoning List command SANbox2 zoning list Active ZoneSet Information ZoneSet Zone ZoneMember wwn wwn_...

Страница 174: ...n ZoneSet Zone ZoneMember wwn wwn_b0241f 50 06 04 82 bf d2 18 c2 50 06 04 82 bf d2 18 d2 21 00 00 e0 8b 02 41 2f wwn_23bd31 50 06 04 82 bf d2 18 c2 50 06 04 82 bf d2 18 d2 10 00 00 00 c9 23 bd 31 wwn_...

Страница 175: ...A named set of ports or devices An alias is not a zone and can not have a zone or another alias as a member AL_PA Arbitrated Loop Physical Address Arbitrated Loop A Fibre Channel topology where ports...

Страница 176: ...Fabric Name User defined name associated with the file that contains user list data for the fabric Fabric Port An F_Port or FL_Port Fabric View File A file containing a set of fabrics that were opened...

Страница 177: ...orkstation PC workstation that manages the fabric through the fabric management switch Mesh Topology A fabric in which each chassis has at least one port directly connected to each other chassis in th...

Страница 178: ...matically discover and communicate freely with all other members of the same zone Target A storage device that responds to an initiator device Translated Loop Port A TL_Port supports a loop of up 124...

Страница 179: ...rename B 6 Alias command B 5 altitude A 4 Arbitrated Loop Physical Address 3 1 B 42 B bandwidth 3 7 beacon B 27 broadcast B 48 browser 4 1 buffer credit 3 6 A 2 C cable 10 100 Base T 4 7 fibre optic...

Страница 180: ...th A 2 latency A 2 management 3 10 A 3 management switch 2 8 management workstation 4 1 point to point bandwidth A 2 ports 2 7 security 3 11 4 9 factory defaults 5 13 B 22 Fallback command B 11 fan 2...

Страница 181: ...ged In 2 6 5 5 Over Temperature 5 9 Over Temperature chassis 2 4 link state database B 49 Link Status LED 2 8 Lip command B 17 log archive B 39 clear B 39 copy 5 13 event B 39 B 63 power on self test...

Страница 182: ...ine test B 71 operational information B 50 performance B 49 B 65 serial 2 9 speed A 2 B 42 POST See Power On Self Test power consumption A 3 down switch 4 19 requirements 4 1 source loading A 3 supply...

Страница 183: ...POST B 22 specifications A 1 system configuration change B 44 display B 67 system processor A 2 T table mount 4 3 target device 2 7 temperature 4 2 A 4 B 48 Test command B 71 This 5 14 time B 10 time...

Страница 184: ...tive B 85 add member zone B 82 copy B 82 create B 82 deactivate B 22 B 82 delete B 83 delete member zone B 83 display B 83 display active B 82 display members B 83 display zones B 79 rename B 83 Zones...

Отзывы: