3 – Planning

Switch Services

59096-04  A

3-15

A

3.6

Switch Services

You can configure your switch to suit the demands of your environment by 
enabling or disabling a variety of switch services. Familiarize yourself with the 
following switch services and determine which ones you need. Notice that the 
SSH and SSL services require the Fabric Security license key.

„

Telnet

: Provides for the management of the switch over a Telnet connection. 

Disabling this service is not recommended. The default is enabled.

„

Secure Shell (SSH)

: Provides for secure remote connections to the switch 

using SSH. Your workstation must also use an SSH client. The default is 
disabled. This service requires the Fabric Security license key. 

„

GUI Management

: Provides for out-of-band management of the switch with 

Enterprise Fabric Suite 2007, the Application Programming Interface (API), 
SNMP, and SMI-S. If this service is disabled, the switch can only be 
managed inband or through the serial port. The default is enabled.

„

Inband Management

: Provides for the management of the switch over an 

inter-switch link using Enterprise Fabric Suite 2007, SNMP, management 
server, or the API. If you disable inband management, you can no longer 
communicate with that switch by means other than an Ethernet or serial 
connection.The default is enabled.

„

Secure Socket Layer (SSL)

: Provides for secure SSL connections for 

Enterprise Fabric Suite 2007, the QuickTools web applet, the API, and 
SMI-S. This service must be enabled to authenticate users through a 
RADIUS server when using Enterprise Fabric Suite 2007. To enable secure 
SSL connections, you must first synchronize the date and time on the switch 
and workstation. Enabling SSL automatically creates a security certificate on 
the switch. The default is enabled. This service requires the Fabric Security 
license key.

„

QuickTools web applet (EmbeddedGUI)

: Provides for access to the 

QuickTools web applet. QuickTools enables you to point at a switch with an 
internet browser and manage the switch through the browser. The default is 
enabled.

„

Simple Network Management Protocol (SNMP)

: Provides for the 

management of the switch through third-party applications that use the 
Simple Network Management Protocol (SNMP). Security consists of a read 
community string and a write community string that serve as passwords that 
control read and write access to the switch. These strings are set at the 
factory to these well-known defaults and should be changed if SNMP is to be 
enabled. Otherwise, you risk unwanted access to the switch. The default is 
enabled.

Содержание SANbox 5000 Series

Страница 1: ...S i m p l i f y R 59096 04 A Page i SANbox 5000 Series Fibre Channel Switch Installation Guide Firmware Version 6 7...

Страница 2: ...on assumes no responsibility for any errors that may appear in this document This SANbox switch is covered by one or more of the following patents 6697359 other patents pending General Devices is trad...

Страница 3: ...7 5 VCCI Class A Statement 1 7 1 7 6 MIC Class A Statement model 5200 only 1 7 1 8 Laser Safety Information 1 8 1 9 Electrostatic Discharge Sensitivity ESDS Precautions 1 8 1 10 Accessible Parts 1 9...

Страница 4: ...abric Suite 2007 2 12 2 6 3 Command Line Interface 2 12 2 6 4 Application Programming Interface 2 12 2 6 5 Simple Network Management Protocol 2 13 2 6 6 Storage Management Initiative Specification SMI...

Страница 5: ...vers 4 6 4 2 3 Configure the Workstation 4 8 4 2 3 1 Configuring the Workstation IP Address for Ethernet Connections 4 8 4 2 3 2 Configuring the Workstation Serial Port 4 9 4 2 4 Connect the Workstati...

Страница 6: ...g a Firmware Image File in Maintenance Mode 5 14 5 5 3 Resetting the Network Configuration in Maintenance Mode 5 15 5 5 4 Resetting User Accounts in Maintenance Mode 5 15 5 5 5 Copying Log Files in Ma...

Страница 7: ...curity Example RADIUS Server 3 23 3 11 Security Example Management Server 3 27 4 1 SANbox 5000 Series Fibre Channel Switch 4 3 4 2 Mounting the Model 5200 5600 Switch in a Rack without Rails 4 5 4 3 M...

Страница 8: ...Page viii 59096 04 A SANbox 5000 Series Fibre Channel Switch Installation Guide S Notes...

Страница 9: ...is an overview of the switch It describes indicator LEDs and all user controls and connections Section 3 describes the factors to consider when planning a fabric Section 4 explains how to install and...

Страница 10: ...ommand Line Interface Guide publication number 59183 01 SANbox Fibre Channel Switch CLI Quick Reference Guide publication number 59261 00 SANbox Simple Network Management Protocol Reference Guide publ...

Страница 11: ...nd installation of a license key Fabric Security provides for Secure Socket Layer SSL and Secure Shell SSH connection security device security using Challenge Handshake Authentication Protocol CHAP an...

Страница 12: ...Warnhinweis weist auf das Vorhandensein einer Gefahr hin die m glicherweise Verletzungen zur Folge hat 4 4 4 5 4 12 4 4 4 5 4 12 6 1 Ein Vorsichtshinweis weist auf das Vorhandensein einer Gefahr hin...

Страница 13: ...erference in which case the user will be required to correct the interference at their own expense Neither the provider nor the manufacturer is responsible for any radio or television interference cau...

Страница 14: ...meets or exceeds the following technical standards EN 60950 1 A11 2004 Safety of Information Technology Equipment EN 55022 1998 A1 2000 A2 2003 Limits and Methods of Measurement of Radio Interference...

Страница 15: ...y Control Council For Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be req...

Страница 16: ...dard requires labeling in English German Finnish and French stating that the product uses Class 1 lasers Because it is impractical to label the transceivers the following label is provided in this man...

Страница 17: ...nits FRU du commutateur SANbox 5000 Series Fibre Channel Switch sont les suivantes Alimentations de courant 5202 5602 Interfaces aux media d interconnexion appel s SFP transceivers Interfaces aux medi...

Страница 18: ...your freedom to share and change it By contrast the GNU General Public License is intended to guarantee your freedom to share and change free software to make sure the software is free for all its use...

Страница 19: ...ion follow 1 13 2 Terms And Conditions For Copying Distribution And Modification 1 This License applies to any program or other work which contains a notice placed by the copyright holder saying it ma...

Страница 20: ...rmally print such an announcement your work based on the Program is not required to print an announcement These requirements apply to the modified work as a whole If identifiable sections of that work...

Страница 21: ...er source or binary form with the major components compiler kernel and so on of the operating system on which the executable runs unless that component itself accompanies the executable If distributio...

Страница 22: ...he balance of the section is intended to apply and the section as a whole is intended to apply in other circumstances It is not the purpose of this section to induce you to infringe any patents or oth...

Страница 23: ...HE PROGRAM IS LICENSED FREE OF CHARGE THERE IS NO WARRANTY FOR THE PROGRAM TO THE EXTENT PERMITTED BY APPLICABLE LAW EXCEPT WHEN OTHERWISE STATED IN WRITING THE COPYRIGHT HOLDERS AND OR OTHER PARTIES...

Страница 24: ...WARRANTY without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE See the GNU General Public License for more details You should have received a copy of the GNU Genera...

Страница 25: ...ogic Technical Support others will be redirected to their authorized maintenance provider Visit the QLogic support Web site listed in Contact Information for the latest firmware and software updates 1...

Страница 26: ...one 1 952 932 4040 Fax 1 952 974 4910 Europe Middle East and Africa Region Email emeasupport qlogic com Phone Numbers by Language 353 1 6924960 English 353 1 6924961 Fran ais 353 1 6924962 Deutsch 353...

Страница 27: ...5000 Series Fibre Channel Switch Command Line Interface Guide for more information about the CLI Refer to the SANbox 5000 Series QuickTools Switch Management User Guide for information about QuickTool...

Страница 28: ...o place the switch in maintenance mode Maintenance mode sets the IP address to 10 0 0 1 and provides access to the switch for maintenance purposes when flash memory or the resident configuration file...

Страница 29: ...he button The Heartbeat LED illuminates continuously while the switch is in maintenance mode To exit maintenance mode and return to normal operation momentarily press and release the Maintenance butto...

Страница 30: ...ST and that the internal switch processor is running In maintenance mode the Heartbeat LED illuminates continuously Refer to Heartbeat LED Blink Patterns on page 5 3 for more information about Heartbe...

Страница 31: ...ly that is hot pluggable The 10 Gbps ports come from the factory with covers that must be removed before installing transceivers or cables 10 Gbps port LEDs are located to the left of their respective...

Страница 32: ...If the port connection is broken or an error occurs that disables the port the Logged In LED is extinguished Refer to Logged In LED Indications on page 5 7 for more information about the Logged In LED...

Страница 33: ...s support generic ports G_Port GL_Port fabric ports F_Port FL_Port and expansion ports E_Port Switches come from the factory with all 1 2 4 Gbps ports configured as GL_Ports The 10 Gbps ports come fro...

Страница 34: ...tch fabric You can manage the switch over an Ethernet connection using the CLI QuickTools Enterprise Fabric Suite 2007 or SNMP The switch through which the fabric is managed is called the fabric manag...

Страница 35: ...onnector requires a null modem F F DB9 cable The pins on the switch RS 232 connector are shown in Figure 2 7 and identified in Table 2 1 Refer to Connect the Workstation to the Switch on page 4 10 for...

Страница 36: ...to indicate that the power supply is receiving AC voltage and producing the proper DC voltages The Power Supply Fault LED amber illuminates to indicate that a power supply fault exists and requires at...

Страница 37: ...latform each switch contains a web applet called QuickTools QuickTools is designed to provide switch management for fabrics with less than four switches For larger fabrics consider the optional manage...

Страница 38: ...or port performance Extended Credits Wizard Zoning Wizard mPort Technology for moveable port licenses Refer to the SANbox 5000 Series Enterprise Fabric Suite 2007 User Guide for information about the...

Страница 39: ...NMP version 1 or 2 Refer to the SANbox Simple Network Management Protocol Reference Guide for more information about using SNMP 2 6 6 Storage Management Initiative Specification SMI S SMI S Provides f...

Страница 40: ...2 General Description Switch Management 2 14 59096 04 A S Notes...

Страница 41: ...4 Gbps ports but the device host bus adapters you are using may not Consider whether the device adapters use SFP or Gigabit Interface Converters GBIC transceivers and choose fiber optic cables accordi...

Страница 42: ...ices Members of the same zone can communicate with each other and transmit outside the zone but cannot receive inbound traffic from outside the zone A port device can be a member of up to eight zones...

Страница 43: ...Latency Table 3 1 Zoning Database Limits Limit Description MaxZoneSets Maximum number of zone sets 256 MaxZones Maximum number of zones 2000 MaxAliases Maximum number of aliases 2500 MaxTotalMembers...

Страница 44: ...s Each port can donate 15 credits to a pool from which a recipient port can borrow However 1 2 4 Gbps ports can borrow only from other 1 2 4 Gbps ports 10 Gbps ports cannot borrow or donate credits Th...

Страница 45: ...n ports if the combined destination bandwidth is greater than or equal to the source bandwidth In multiple chassis fabrics each link between chassis contributes 212 424 850 or 2550 megabytes of bandwi...

Страница 46: ...ure Socket Layer SSL protocol and Telnet connections using the Secure Shell SSH protocol Device and switch authorization and authentication using the Challenge Handshake Authentication Protocol CHAP R...

Страница 47: ...a wide variety of topologies Consider your topology and cabling requirements 3 5 1 Optimizing Device Performance When choosing a topology for a multiple chassis fabric you should also consider the loc...

Страница 48: ...cipal priority set to 254 Refer to the Set Config Switch command in the SANbox 5000 Series Fibre Channel Switch Command Line Interface Guide for information about changing the default domain ID domain...

Страница 49: ...performance and redundancy Each 10 Gbps port contributes 1 GB of bandwidth between chassis with one chassis hop between any two ports Figure 3 1 shows a two switch stack of model 5000 switches using t...

Страница 50: ...sing three 3 inch and three 9 inch XPAK switch stacking cables 64 1 2 4 Gbps ports are available for devices Figure 3 3 Four Switch Stack Figure 3 4 shows a five switch stack of model 5000 switches us...

Страница 51: ...tches using eight XPAK switch stacking cables Ninety six 1 2 4 Gbps ports are available for devices Figure 3 5 Six Switch Stack 3 5 4 Common Topologies The SANbox 5000 Series switch supports the follo...

Страница 52: ...use any switch can route traffic in the shortest direction to any switch in the loop The loop also provides failover should a switch fail Each chassis link contributes up to 425 MB of bandwidth betwee...

Страница 53: ...0 Series switches the mesh fabric shown in Figure 3 7 has the following characteristics Each link contributes up to 425 MB of bandwidth between switches 850 MB in full duplex Because of multiple paral...

Страница 54: ...etween chassis Competition for this bandwidth is less than that of a cascade topology but greater than that of the mesh topology Latency between any two ports is no more than two chassis hops 52 1 2 4...

Страница 55: ...ment you can no longer communicate with that switch by means other than an Ethernet or serial connection The default is enabled Secure Socket Layer SSL Provides for secure SSL connections for Enterpri...

Страница 56: ...implementation that meets the security policy requirements Internet portals such as remote access and E mail usually present the greatest threats Fabric security should also be considered in defining...

Страница 57: ...te using the Create Certificate CLI command Refer to the SANbox 5000 Series Fibre Channel Switch Installation Guide for information about the Create Certificate CLI command Consider your requirements...

Страница 58: ...sider your management needs and determine the number of user accounts their authority needs and expiration dates Also consider the advantages of centralizing user administration and authentication on...

Страница 59: ...e switch can be configured to require authentication to validate the identity of the connecting switch device or host Authentication can be performed locally using the switch s security database or re...

Страница 60: ...ches and HBAs with Authentication Consider the fabric shown in Figure 3 9 In this fabric Switch_1 HBA_1 and Switch_2 support authentication while the JBOD and HBA_2 do not The objective is to secure F...

Страница 61: ...the HBA security database For example if you specify a switch with a port worldwide name in the switch security database you must also specify that switch in the HBA security database with the same p...

Страница 62: ...te a security set Security_Set_2 on Switch_2 Create an ISL group Group_ISL_2 in Security_Set_2 with Switch_2 and Switch_1 as members 5 Save and activate Security_Set_2 on Switch_2 ISL Group on Switch_...

Страница 63: ...s passed from the switch to Radius_1 in the following cases HBA_1 login to Switch_1 Switch_1 login to Switch_2 Switch_2 login to Switch_1 Figure 3 10 Security Example RADIUS Server Device Switch_1 WWN...

Страница 64: ...s unavailable Radius_1 Configuration on Switch_1 and Switch_2 Device Authentication Order RadiusLocal Authenticate devices using the RADIUS server security database first If the RADIUS server is unava...

Страница 65: ...ldwide name you use in the switch security database must be the same as that in the HBA security database For example if you specify a switch with a port worldwide name in the switch security database...

Страница 66: ...curity set Security_Set_2 on Switch_2 Create an ISL group Group_ISL_2 in Security_Set_2 with Switch_1 and Switch_2 as members 6 Save and activate Security_Set_2 on Switch_2 ISL Group on Switch_1 Group...

Страница 67: ...lication The objective is to secure the management server on Switch_2 from unauthorized access by an HBA or an associated host application Figure 3 11 Security Example Management Server Device HBA_1 A...

Страница 68: ...witch security database you must also specify that switch in the HBA security database with the same port worldwide name For MD5 authentication create secrets 3 Configure security on HBA_2 or APP_2 us...

Страница 69: ...eside in the switch firmware and provide for the management of individual switches in a single fabric Consider how many fabrics and switches will be managed how many management workstations are needed...

Страница 70: ...3 Planning Fabric Management 3 30 59096 04 A S Notes...

Страница 71: ...cs are covered Site Requirements Installing a Switch Installing Firmware Adding a Switch to an Existing Fabric Installing Feature License Keys 4 1 Site Requirements Consider the following items when i...

Страница 72: ...heat dissipation and ventilation The switch requires the following operating conditions Operating temperature range 5 40 C 41 104 F Relative humidity 15 80 non condensing Table 4 1 Management Worksta...

Страница 73: ...07 switch management application release notes and documentation Figure 4 1 SANbox 5000 Series Fibre Channel Switch Installing a SANbox 5000 Series switch involves the following steps 1 Mount the Swit...

Страница 74: ...39 0100 317 897 7000 www generaldevices com A model 5202 5602 switch requires a QLogic rail kit part numbers SB5202 RACKKIT and SB5602 RACKKIT for rack mounting WARNING Mount switches in the rack so t...

Страница 75: ...to install the chassis in an environment that is compatible with the maximum rated ambient temperature Refer to Environmental on page A 5 for technical specifications Do not restrict chassis air flow...

Страница 76: ...er insert the transceiver into the port and gently press until it snaps in place To remove a transceiver gently press the transceiver into the port to release the tension then pull on the release tab...

Страница 77: ...on the cable connectors with the circuit board toward the mid line of the respective switch faceplates as shown in Figure 4 5 When installing the 3 inch XPAK switch stacking cable insert the cable con...

Страница 78: ...nicate with the 10 0 0 subnet refer to the following instructions for your workstation For a Windows workstation do the following 1 Choose the Start button Choose Settings Control Panel Network and Di...

Страница 79: ...Enter the following COM Port settings in the COM Properties window and choose the OK button Bits per second 9600 Data Bits 8 Parity None Stop Bits 1 Flow Control None For Linux a Set up minicom to use...

Страница 80: ...switch RJ 45 Ethernet connector through an Ethernet switch or a hub This requires a 10 100 Base T straight cable as shown in Figure 4 6 Direct Ethernet connection from the management workstation to th...

Страница 81: ...e must be rated at 10 Amps and be approved by UL and CSA For 250 Volt electrical service The cable must be rated at 10 Amps meet the requirements of H05VV F and be approved by VDE SEMKO and DEMKO AVER...

Страница 82: ...Metallteilen des switch Geh uses verursachen Der Kunde tr gt die Verantwortung f r eine vorschriftsm ige Verdrahtung und Erdung der Steckdose zur Vermeidung eines elektrischen Schlages In manchen L nd...

Страница 83: ...bled 2 After a couple seconds the System Fault LED is extinguished while the Input Power LED and Heartbeat LED remain illuminated 3 After approximately one minute the POST executes and the Heartbeat L...

Страница 84: ...using the default user name admin and password password 3 Obtain the IP address and subnet mask from your network administrator 4 Open the QuickTools Wizards menu and select Configuration Wizard Foll...

Страница 85: ...choose the OK button Serial Linux Open a command window and enter the following command minicom Serial Solaris Open a command window and enter the following command tip hardwire 2 Open an admin sessio...

Страница 86: ...e as FL_Ports when connected to loop of devices or F_Ports when connected to a single device G_Ports self configure as F_Ports when connected to a single device Both GL_Ports and G_Ports self configur...

Страница 87: ...onfigurations or installing firmware No port in the fabric is in the diagnostic state No Zoning Edit sessions are open in the fabric No changes are being made to attached devices including powering up...

Страница 88: ...tall or Image Install command to download the firmware image file from an FTP or TFTP server unpack it and activate it in one step Refer to One Step Firmware Installation on page 4 18 For a non disrup...

Страница 89: ...nt and a password TFTP does not FTP or TFTP ftp 3 Enter your account name on the remote host FTP only and the IP address of the remote host When prompted for the source file name enter the path for th...

Страница 90: ...h account_name ip_address filename If your workstation has a TFTP server you can enter the Image TFTP command to download the firmware image file SANbox admin image tftp ip_address filename If your wo...

Страница 91: ...hernet port you must first configure the IP address 3 Plug in the inter switch links ISL but do not connect the devices 4 Configure the port types for the new switch The ports can be G_Port GL_Port F_...

Страница 92: ...4 Installation Installing Feature License Keys 4 22 59096 04 A S Notes...

Страница 93: ...st Diagnostics describe the Heartbeat LED and the port Logged In LED indications Power Supply Diagnostics describes Power Supply Status LED and Power Supply Fault LED indications for model 5202 5602 s...

Страница 94: ...h if the condition remains contact your authorized maintenance provider For a model 5202 5602 switch if the condition remains continue 3 Inspect the power supplies Are the power supplies fully seated...

Страница 95: ...cond If a critical error occurs the Heartbeat LED will show an error blink pattern and the System Fault LED will illuminate If there are non critical errors the switch disables the failed ports and fl...

Страница 96: ...that the switch must be reset Momentarily press and release the Maintenance button to reset the switch 5 2 1 2 Fatal POST Error Blink Pattern A system error blink pattern is 3 blinks followed by a two...

Страница 97: ...using Telnet Enter one of the following on the command line telnet xxx xxx xxx xxx or telnet switchname where xxx xxx xxx xxx is the switch IP address and switchname is the switch name associated with...

Страница 98: ...continue Is the Power Supply Fault LED illuminated on either power supply Yes Replace the power supply If the condition remains continue No Continue 3 For a model 5202 5602 switch observe the air flow...

Страница 99: ...port or the port is in the diagnostics state Flashing twice per second The port is down offline or an error has occurred If a Logged In LED is flashing twice per second review the event browser for a...

Страница 100: ...rm about an invalid attach on the affected port Yes Review the ISL group in the active security set to ensure that the membership includes the necessary ports and that the secrets on all switches are...

Страница 101: ...tivate one of the active zone sets or edit the conflicting zones so that their membership is the same Reset the port If the condition remains contact your authorized maintenance provider 5 2 2 2 Exces...

Страница 102: ...eshold command Refer to the Show Config Threshold command in the SANbox 5000 Series Fibre Channel Switch Command Line Interface Guide Are the thresholds and sample window correct Yes Continue No Corre...

Страница 103: ...rt number Manufacturer Temperature C Operating voltage volts Transmitter bias milliamps Transmitter power milliwatts Receiver power milliwatts The display indicates warning and alarm conditions for bo...

Страница 104: ...Heartbeat LED does not show a blink pattern This means that the two power supplies have different air flow directions Replace the power supply with the incorrect air flow direction with another having...

Страница 105: ...ork Configuration in Maintenance Mode Resetting User Accounts in Maintenance Mode Copying Log Files in Maintenance Mode Removing the Switch Configuration in Maintenance Mode Remaking the File System i...

Страница 106: ...ration momentarily press and release the Maintenance button or power cycle the switch 5 5 2 Unpacking a Firmware Image File in Maintenance Mode This option unpacks and installs new firmware when the c...

Страница 107: ...Mode This option restores the password for the Admin account name to the default password and removes all other user accounts from the switch 5 5 5 Copying Log Files in Maintenance Mode This option c...

Страница 108: ...e Switch in Maintenance Mode This option closes the Telnet session exits maintenance mode and reboots the switch using the current switch configuration All unpacked firmware image files that reside on...

Страница 109: ...ceiver manufacturers have different release mechanisms Consult the documentation for your transceiver To install insert the transceiver into the port and gently press until it snaps in place WARNING D...

Страница 110: ...e air flow direction The part number label on the power supply indicates the air flow direction When removing or replacing a power supply on an operating switch be sure the Heartbeat LED is showing th...

Страница 111: ...supply is compatible with the switch air flow direction The part number label on the power supply indicates the air flow direction as shown in Figure 6 2 3 With the AC receptacle on the right slide th...

Страница 112: ...6 Removal Replacement Power Supply Removal and Replacement 6 4 59096 04 A S Notes...

Страница 113: ...FC PH Rev 4 3 FC PH 2 FC PH 3 FC AL Rev 4 6 FC AL 2 Rev 7 0 FC FLA FC GS FC GS 2 FC GS 3 FC FG FC Tape FC VI FC SW 2 Fibre Channel Element MIB RFC 2837 Fibre Alliance MIB Version 4 0 Fibre Channel Cla...

Страница 114: ...Maximum User Ports 475 000 ports depending on configuration Buffer Credits 16 buffer credits per port ASIC embedded memory Media Type Ports 0 15 Ports 16 19 SFP optical transceiver XPAK switch stacki...

Страница 115: ...Duplex Bandwidth Point to Point Aggregate single switch 212 MB Full Duplex 1 Gbps 224 MB Full Duplex 2 Gbps 850 MB Full Duplex 4 Gbps1 2550 MB Full Duplex 10 Gbps Up to 23 80 GB Full Duplex 1 5600 se...

Страница 116: ...tenance Connection RS 232 connector null modem F F DB9 cable Ethernet Connection RJ 45 connector 10 100 BASE T cable Switch Agent Allows a network management station to obtain configuration values tra...

Страница 117: ...ng Non operating 5 to 40 C 41 to 104 F 40 to 70 C 40 to 158 F Humidity Operating Non operating 5 to 90 non condensing 5 to 93 non condensing Altitude Operating Non operating 0 to 3048m 0 to 10 000 fee...

Страница 118: ...50 00 Canada EN60950 EC CB Scheme IEC 60950 Emissions Standards FCC Part 15B Class A ICES 03 Issue 3 VCCI Class A ITE CISPR 22 Class A EN 55022 Class A Voltage Fluctuations EN 61000 3 3 Harmonics EN 6...

Страница 119: ...gured Alias A named set of ports or devices An alias is not a zone and can not have a zone or another alias as a member AL_PA Arbitrated Loop Physical Address Arbitrated Loop A Fibre Channel topology...

Страница 120: ...itch through the use of groups and security sets Domain ID User defined number that identifies the switch in the fabric Event Log Log of messages describing events that occur in the fabric Expansion P...

Страница 121: ...nge with a target device In Order Delivery A feature that requires that frames be received in the same order in which they were sent Input Power LED A chassis LED that indicates that the switch logic...

Страница 122: ...er Switch Manager Switch management application Simple Network Management Protocol An application protocol that manages and monitors network communications and functions It also controls the Managemen...

Страница 123: ...ide Name WWN A unique 64 bit address assigned to a device by the device manufacturer WWN Worldwide Name XPAK A specification authored by a consortium of companies to govern the development of small fo...

Страница 124: ...SANbox 5000 Series Fibre Channel Switch Installation Guide Glossary 6 59096 04 A S Notes...

Страница 125: ...F F DB9 4 10 XPAK switch stacking 4 7 cascade topology 3 12 certificate 3 17 chassis air flow A 5 diagnostics 5 1 LEDs 2 3 marking A 6 shock A 5 vibration A 5 classes of service A 1 command line inter...

Страница 126: ...Unit 6 1 A 3 File Transfer Protocol account name 4 20 description 2 13 service 3 16 firmware description 4 16 failure 5 4 install with CLI 4 18 install with QuickTools 4 18 non disruptive activation 4...

Страница 127: ...minicom 4 9 multiple chassis fabrics 3 7 N new features 1 3 non critical error 5 3 non disruptive activation 4 17 NTP See Network Time Protocol null modem F F DB9 cable 4 10 O operating systems 4 2 o...

Страница 128: ...service 3 15 security certificate 3 17 connection 3 17 database limits 3 19 device 3 19 fabric 3 16 user account 3 17 serial port 2 9 4 9 4 10 SFP See Small Form Factor Pluggable shock A 5 Simple Netw...

Страница 129: ...4 6 6 1 transmission rate 3 3 3 5 two switch stacking 3 9 U upgrade 2 5 user account security 3 17 user interface A 3 V vibration A 5 voltage fluctuations A 6 operating A 5 W web applet description 2...

Страница 130: ...SANbox 5000 Series Fibre Channel Switch Installation Guide Index 6 59096 04 A S Notes...

Отзывы: