4 – Configuring the Host and VMM Servers
Configuring QLogic SANsurfer FC HBA Manager on the VMM Server
FC0054605-00 A
4-3
A
Configuring QLogic SANsurfer FC HBA Manager
on the VMM Server
This section describes how to configure the QLogic SANsurfer FC HBA Manager
GUI on the VMM server to allow QLogic FC adapters that reside on host servers
to be managed via the VMM server. Alternately, you can use QLogic’s SANsurfer
FC HBA CLI to achieve the tasks below. Note that CLI does not support remote
management of QLogic FC adapters, so it must be deployed and used directly on
the host servers (Hyper-V).
1.
Start the QLogic SANsurfer FC HBA Manager GUI on the VMM server by
either double-clicking the SANsurfer icon on the desktop or selecting
SANsurfer FC HBA Manager from the Start menu.
2.
Click the
Connect
button in the toolbar and type the IP address or name of a
host server on which the QLogic FC adapter resides (see
Figure 4-2
).
Figure 4-2. SANsurfer FC HBA Manager —Connect to Host
3.
Repeat
Step 2
until all host servers have been connected to the SANsurfer
FC HBA Manager.