50
FUNCTION INDICATORS ON INDOOR UNIT DISPLAY PANEL
a
b
d
c
a
DEFROST indicator
This indicator illuminates when the air conditioner starts defrosting automatically or when the warm
air control feature is activated in heating operation.
b
TEMPERATURE indicator
Displays the temperature settings when the air conditioner is operational.
c
OPERATION indicator
This indicator flashes after power is on and illuminates when the unit is in operation.
d
TIMER indicator
This indicator illuminates when TIMER is set ON/OFF.
C
OPERATING TEMPERATURE
Cooling, heating and / or dehumidifying are effective at the following indoor and outdoor temperatures:
Temperature
Mode
Cooling operation
Heating operation
Dehumidifying operation
Room temperature
17ºC - 32ºC
0ºC - 30ºC
10ºC - 32ºC
Outdoor temperature
-25ºC - 50ºC
-15ºC - 30ºC
0ºC - 50ºC
CAUTION
• If air conditioner is used outside of the above conditions, certain safety protection features may
come into operation and cause the unit to function abnormally.
• If the air conditioner operates in excess of a relative humidity of 80% in the room, the surface
of the air conditioner may attract condensation. Please set the vertical air flow louver to its
maximum angle (vertically to the floor), and set HIGH fan mode.
• For maximum effect of your air conditioner always close doors and windows when cooling or
heating.
4
50