4
G
TURNING THE HEATER OFF
1 Press the ON / OFF button
21
. The red lamp flashes for about 8 seconds and the
heater is turned off. Always check that the flame goes out.
The ventilator continues operating for about 3 minutes after turning off in order
to cool the inside of the heater. If you turn off the power earlier, uncontrolled
symptoms can occur (release of smoke, smell etc.)..
H
IN CASE OF PROBLEMS
The symptoms mentioned above are not faults and not abnormal.
Check the list.
Symptoms
Causes
While igniting
Igniting is tedious
Igniting takes about 45 seconds.
After filling the tank, wait till
the fuel has reached the fixed
tank. Repeat ignition 2 or 3
times.
Crackling sound
This sound is made by the elec-
tric ignition.
White smoke
This can happen if the fuel does
not circulate past the burner
properly
During ignition
or turning off
Smoke and an unpleasant smell
during first use
That is the protective lacquer
getting warm. This soon stops.
Give the space more ventila-
tion.
The ambient temperature does
not increase and the requested
temperature is higher.
The space is too large.
The flame glows red.
The ambient air is damp or salty
or it contains too many impu-
rities.
The ambient temperature does
not decrease and the requested
temperature is lower.
The heater is being used in a
small insulated space or the
outside temperature is relati-
vely high. Turn the heater off.
The displayed ambient tempe-
rature is not the same as indica-
ted by a thermometer.
This is because the displayed
ambient temperature is an indi-
cation of the average tempera-
ture of the space.
Small knocking noises when the
heater is in operation or imme-
diately after turning off.
This is the sound of the metal
expanding.
Noise 8 seconds after turning
off.
A ticking sound: can occur
when the heater cools off.