78
SC 4348
6.2 Drilling the piping, condensation hose and cable feed-through.
a.
Determine the positions of the holes according to the diagram detailed in Fig. 9. Drill one (1) hole
slanting slightly downwards to outdoor side, this will prevent water to come indoors (fig 10).
b.
Always use wall hole conduit when drilling metal grid, metal plate or the like.
Wall
Indoor
Outdoor
Figure 10
≥
5°
5
-
7
mm
per
100
mm
7. CONNECTING THE COOLANT PIPES
7.1 Connecting and disconnecting the coolant pipes
TOOLS NEEDED
-
You will require the following tools to carry out this installation work correctly:
1x open-ended spanner, 19 mm
1x open-ended spanner, 22 mm/24mm
1x open-ended spanner, 24 mm/27mm
1x Allen key, 5 mm
1x Philips screwdriver
1x leak detection spray or alternatively soap suds (water/detergent mix)
4
78
Q_instal_SC42xx_SC52xx_SCJAxx19 EU ('20) V4.indd 78