78
GB
CAUTION
• The AIR DIRECTION and SWING buttons will be disabled when the air conditioner is not in
operation (including when the TIMER ON is set).
• Do not operate the air conditioner for long periods with the air flow direction set downward
in cooling or dry mode. Otherwise, condensation may occur on the surface of the horizontal
louver causing moisture to drop.
• Do not move the horizontal louver manually. Always use the AIR DIRECTION
h
or SWING
button
g
. If you move this louver manually, it may malfunction during operation. If the louver
malfunctions, stop the air conditioner once and restart it.
• When the air conditioner is started immediately after it was stopped, the horizontal louver
might not move for approximately 10 seconds.
• Do not operate unit with horizontal louver in closed position.
J
HOW THE AIR CONDITIONER WORKS
AUTOMATIC OPERATION
•
When you set the air conditioner in AUTO mode (button
2
on the remote
controller), it will automatically select COOLING, HEATING or FAN only oper-
ation depending on what temperature you have selected and the room tem-
perature.
•
The air conditioner will control room temperature automatically round the
temperature point set by you.
•
If the AUTO mode is uncomfortable, you can select desired conditions manu-
ally.
SLEEP/ECONOMIC OPERATION
•
When you push SLEEP button
f
during COOLING, HEATING or AUTO oper-
ation, the air conditioner will automatically increase (cooling) or decrease
(heating) 1ºC per hour. The set temperature will be steady 2 hours later and
remains steady for 5 hours. After 5 hours the unit will stop. The fan speed
will be automatically controlled.
DEHUMIDIFYING OPERATION
•
The dehumidifying mode will automatically select the dehumidifying operation based on the difference
between the set temperature and the actual room temperature.
•
The temperature is regulated while dehumidifying by repeatingly turning on and off of the cooling
operation or fan only. The fan speed is controlled automatically.
•
In normal cooling operation the air conditioner will also dehumidify the air.
G
NOTE
When the air conditioner is dehumidifying it is likely that the room temperature will decrease.
It is therefore normal that a hygrostat will measure a higher relative humidity. The absolute
humidity in the room will however be lowered, depending on the amount of moisture produced
in the room (cooking, people etc).
1
1
1
1
Press Sleep button
Press Sleep button
COOLING
HEATING
DEHUMIDIFYING
Set
Tempe-
rature
1 hour
1 hour
1 hour
1 hour
Set
Tempe-
rature
Set temperature
Time
Room
tempe-
rature
Cooling Fan only Cooling Fan only Cooling